Bioanalytical LC-MS/MS of protein-based biopharmaceuticals

被引:170
|
作者
van den Broek, Irene [1 ]
Niessen, Wilfried M. A. [2 ,3 ]
van Dongen, William D. [1 ]
机构
[1] TNO Triskel, NL-3704 AV Zeist, Netherlands
[2] Hyphen MassSpec, NL-2332 XT Leiden, Netherlands
[3] Vrije Univ Amsterdam, Fac Sci, AIMMS Div BioMol Anal, NL-1081 HV Amsterdam, Netherlands
关键词
Bioanalysis; LC-MS; Monoclonal antibodies; Therapeutic protein; Absolute quantification; Sample preparation; TANDEM MASS-SPECTROMETRY; PEPTIDE IMMUNOAFFINITY ENRICHMENT; THERAPEUTIC MONOCLONAL-ANTIBODIES; PROSTATE-SPECIFIC ANTIGEN; RECOMBINANT-HUMAN-ERYTHROPOIETIN; ORTHOGONAL ARRAY OPTIMIZATION; FUSION INHIBITOR ENFUVIRTIDE; HUMAN CHORIONIC-GONADOTROPIN; HUMAN GROWTH-HORMONE; C-REACTIVE PROTEIN;
D O I
10.1016/j.jchromb.2013.04.030
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Biotechnology increasingly delivers highly promising protein-based biopharmaceutical candidates to the drug development funnel. For successful biopharmaceutical drug development, reliable bioanalytical methods enabling quantification of drugs in biological fluids (plasma, urine, tissue, etc.) are required to generate toxicokinetic (TK), pharmacokinetic (PK), and bioavailability data. A clear observable trend is that liquid chromatography coupled to (tandem) mass spectrometry (LC-MS(/MS)) is more and more replacing ligand binding assays (LBA) for the bioanalytical determination of protein-based biopharmaceuticals in biological matrices, mainly due to improved selectivity and linear dynamic ranges. Practically all MS-based quantification methods for protein-based biopharmaceuticals traditionally rely on (targeted) proteomic techniques and include "seven critical factors": (1) internal standardization, (2) protein purification, (3) enzymatic digestion, (4) selection of signature peptide(s), (5) peptide purification, (6) liquid chromatographic separation and (7) mass spectrometric detection. For this purpose, the variety of applied strategies for all "seven critical factors" in current literature on MS-based protein quantification have been critically reviewed and evaluated. Special attention is paid to the quantification of therapeutic monoclonal antibodies (mAbs) in serum and plasma since this is a very promising and rapidly expanding group of biopharmaceuticals. Additionally, the review aims to predict the impact of strategies moving away from traditional protein cleavage isotope dilution mass spectrometry (PC-IDMS) toward approaches that are more dedicated to bioanalysis. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:161 / 179
页数:19
相关论文
共 50 条
  • [41] Critical review of development, validation, and transfer for high throughput bioanalytical LC-MS/MS methods
    Zhou, Shaolian
    Song, Qi
    Tang, Yong
    Weng, Naidong
    CURRENT PHARMACEUTICAL ANALYSIS, 2005, 1 (01) : 3 - 14
  • [42] Bioanalytical method development and validation of a novel antiseizure agent Cenobamate using LC-MS/MS
    Rao, Yamarthi Venkateswara
    Shaik, Rasheed Ahemad
    Chimakurthy, Jithendra
    INTERNATIONAL JOURNAL OF NANOTECHNOLOGY, 2023, 20 (1-4) : 63 - 74
  • [43] TROUBLE SHOOTING DURING BIOANALYTICAL ESTIMATION OF DRUG AND METABOLITES USING LC-MS/MS: A REVIEW
    Sharma, Ganesh N.
    Singhal, Man Mohan
    Sharma, K. K.
    Sanadya, Jyotsana
    JOURNAL OF ADVANCED PHARMACEUTICAL TECHNOLOGY & RESEARCH, 2010, 1 (01) : 1 - 9
  • [44] Quantification below the LLOQ in regulated LC-MS/MS assays: a review of bioanalytical considerations and cautions
    Duggan, Jeffrey X.
    BIOANALYSIS, 2019, 11 (08) : 797 - 814
  • [45] Optimizing LC-MS and LC-MS-MS Methods
    不详
    LC GC EUROPE, 2014, 27 (01) : 50 - 50
  • [46] Optimizing LC-MS and LC-MS-MS Methods
    不详
    LC GC NORTH AMERICA, 2014, 32 (01) : 74 - 74
  • [47] Determination of penicillins in milk using LC-UV, LC-MS and LC-MS/MS
    Martinez-Huelamo, Miriam
    Jimenez-Gamez, Esther
    Pilar Hermo, Maria
    Barron, Dolores
    Barbosa, Jose
    JOURNAL OF SEPARATION SCIENCE, 2009, 32 (14) : 2385 - 2393
  • [48] Response Factor based Quantification in LC-MS/MS
    Pauwels, S.
    Peersman, N.
    Gerits, M.
    Desmet, K.
    Vermeersch, P.
    ACTA CLINICA BELGICA, 2014, 69 : 6 - 7
  • [49] LC-MS/MS for protein and peptide quantification in clinical chemistry
    Rauh, Manfred
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 883 : 59 - 67
  • [50] Direct bioanalytical sample injection with 2D LC-MS
    Cassiano, N. M.
    Barreiro, J. C.
    Oliveira, R. V.
    Cass, Q. B.
    BIOANALYSIS, 2012, 4 (22) : 2737 - 2756