Comparison between average shear rates in conventional bioreactor with Rushton and Elephant ear impellers

被引:46
|
作者
Bustamante, M. C. C. [1 ]
Cerri, M. O. [1 ]
Badino, Alberto C. [1 ]
机构
[1] Univ Fed Sao Carlos, Dept Chem Engn, BR-13565905 Sao Carlos, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Biochemical engineering; Bioreactors; Mass transfer; Mixing; Momentum transfer; Non-Newtonian fluids; MASS-TRANSFER COEFFICIENT; STREPTOMYCES-CLAVULIGERUS; DISSOLVED-OXYGEN; ACID PRODUCTION; STIRRED-TANK; POWER; FERMENTATION; VESSELS; REACTOR; LIQUID;
D O I
10.1016/j.ces.2012.12.028
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
As an alternative to the Rushton turbine impeller (RT), the Elephant ear impeller (EE) has been indicated as suitable for the cultivation of shear-sensitive cells such as animal cells and filamentous fungi. In the present work the average shear rate ((gamma) over dot(av)) was evaluated and compared in a conventional bench-scale stirred-tank bioreactor, using different impeller configurations such as the Rushton turbine and the Elephant ear turbine in the down-pumping (EEDP and up-pumping (EEUP) modes. Based on recent methodology, correlations to estimate the average shear rate ((gamma) over dot(av)) were obtained for the different impellers according to the rotational impeller speed (N), specific air flow rate (phi(air)), and rheological properties of non-Newtonian pseudoplastic fluids. Values of (gamma) over dot(av) predicted by the proposed method were within the range of values calculated by the correlations found in the literature, indicating that the proposed method generates reliable values of (gamma) over dot(av). The (gamma) over dot(av) values obtained for the RT and EEDP impellers increase with the increase of N and decrease with the increase of phi(air) for all non-Newtonian fluids. In contrast, for the EEUP impeller (gamma) over dot(av) values decrease with the increase of N and phi(air). The negative influence of phi(air) in (gamma) over dot(av) at constant agitation (N) for all impellers was attributed to the increase of the gas hold-up by the increase of phi(air). EE impellers generated values of (gamma) over dot(av) lower than that observed in the system equipped with the RT impeller. EEUP was the impeller that combined good oxygen mass transfer and low shear, appropriate characteristics for its use in bioprocesses involving shear-sensitive microorganisms. The importance of the correlations developed in the present work is that they allow estimation and comparison of the shear conditions in cultures as a function of the operating conditions (N, phi(air)), rheological properties of the fluid (K and n), and volumetric oxygen transfer coefficient (k(L)a) in conventional bioreactors equipped with different impeller configurations in turbulent flow regime. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:92 / 100
页数:9
相关论文
共 50 条
  • [21] Comparison of nitrification performance and microbial community between submerged membrane bioreactor and conventional activated sludge system
    Li, H
    Yang, M
    Zhang, Y
    Liu, X
    Gao, M
    Kamagata, Y
    WATER SCIENCE AND TECHNOLOGY, 2005, 51 (6-7) : 193 - 200
  • [22] Cytohistologic correlation rates between conventional Papanicolaou smears and ThinPrep cervical cytology: A comparison
    Chacho, MS
    Mattie, ME
    Schwartz, PE
    CANCER CYTOPATHOLOGY, 2003, 99 (03) : 135 - 140
  • [23] Comparison of bonding time and shear bond strength between a conventional and a new integrated bonding system
    Bishara, SE
    Oonsombat, C
    Soliman, MMA
    Warren, JJ
    Laffoon, JF
    Ajlouni, R
    ANGLE ORTHODONTIST, 2005, 75 (02) : 237 - 242
  • [24] A COMPARISON BETWEEN A CONVENTIONAL SUBMERGED CULTURE FERMENTER AND A NEW CONCEPT GAS SOLID FLUID BED BIOREACTOR FOR GLUTATHIONE PRODUCTION
    BAUER, W
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1986, 64 (04): : 561 - 566
  • [25] Removal of a broad range of surfactants from municipal wastewater -: Comparison between membrane bioreactor and conventional activated sludge treatment
    Gonzalez, Susana
    Petrovic, Mira
    Barcelo, Damia
    CHEMOSPHERE, 2007, 67 (02) : 335 - 343
  • [26] Removal of 17-β estradiol from wastewater: comparison between a laboratory scale conventional activated sludge and a membrane bioreactor
    Lopez-Fernandez, R.
    Tavares, F. V. F.
    Gomez, M.
    Irusta, R.
    Le-Clech, P.
    DESALINATION AND WATER TREATMENT, 2013, 51 (10-12) : 2336 - 2342
  • [27] Comparison between a submerged membrane bioreactor and a conventional activated sludge system on treating ammonia-bearing inorganic wastewater
    Gao, MC
    Yang, M
    Li, HY
    Yang, QX
    Zhang, Y
    JOURNAL OF BIOTECHNOLOGY, 2004, 108 (03) : 265 - 269
  • [28] Shear bond strength comparison between two orthodontic adhesives and self-ligating and conventional brackets
    Northrup, Rodney G.
    Berzins, David W.
    Bradley, Thomas Gerard
    Schuckit, William
    ANGLE ORTHODONTIST, 2007, 77 (04) : 701 - 706
  • [29] A comparison of average rates of alluvial erosion between the south-western and south-eastern United States
    Jaeger, Kristin L.
    Wohl, Ellen
    Simon, Andrew
    EARTH SURFACE PROCESSES AND LANDFORMS, 2010, 35 (04) : 447 - 459
  • [30] Comparison of survival rates between patients treated with conventional radiotherapy and helical tomotherapy for head and neck cancer
    Kong, Moonkyoo
    Hong, Seong Eon
    Choi, Jinhyun
    Kim, Youngkyong
    RADIATION ONCOLOGY JOURNAL, 2013, 31 (01): : 1 - 11