Impedance Study of Dopamine Effects after Application on 2D and 3D Neuroblastoma Cell Cultures Developed on a 3D-Printed Well

被引:4
|
作者
Paivana, Georgia [1 ]
Apostolou, Theofylaktos [1 ]
Mavrikou, Sophie [1 ]
Barmpakos, Dimitris [2 ,3 ]
Kaltsas, Grigoris [2 ]
Kintzios, Spyridon [1 ]
机构
[1] Agr Univ Athens, Dept Biotechnol, Lab Cell Technol, GR-11855 Athens, Greece
[2] Univ West Attica, microSENSES Lab, Dept Elect & Elect Engn, Athens 12244, Greece
[3] Natl Ctr Sci Res Demokritos, Inst Nanosci & Nanotechnol, Athens 15341, Greece
关键词
impedance study; dopamine; immobilization; N2a cells; AMINO-ACID NEUROTRANSMITTERS; MICROFLUIDIC DEVICES; ELECTRODE; CHROMATOGRAPHY; POINT; RAT;
D O I
10.3390/chemosensors7010006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, the assessment of the interactions of a bioactive substance applied to immobilized cells in either a two-dimensional (2D) or three-dimensional (3D) arrangement mimicking in vivo tissue conditions is presented. In particular, dopamine (DA) was selected as a stimulant for the implementation of an impedance analysis with a specific type of neural cells (murine neuroblastoma). The aim of this study was the extraction of calibration curves at various frequencies with different known dopamine concentrations for the description of the behavior of dopamine applied to 2D and 3D cell cultures. The results present the evaluation of the mean impedance value for each immobilization technique in each frequency. The differential responses showed the importance of the impedance when frequency is applied in both 2D and 3D immobilization cases. More specifically, in 2D immobilization matrix impedance shows higher values in comparison with the 3D cell culture. Additionally, in the 3D case, the impedance decreases with increasing concentration, while in the 2D case, an opposite behavior was observed.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] 2D or not 2D That is the Question, but 3D is the, answer
    Cronin, Paul
    ACADEMIC RADIOLOGY, 2007, 14 (07) : 769 - 771
  • [42] 3D-Printed Bioreactor with Integrated Impedance Spectroscopy for Cell Barrier Monitoring
    Linz, Georg
    Rauer, Sebastian Bernhard
    Kuhn, Yasmin
    Wennemaring, Simon
    Siedler, Laura
    Singh, Smriti
    Wessling, Matthias
    ADVANCED MATERIALS TECHNOLOGIES, 2021, 6 (06):
  • [43] THE APPLICATION OF 2D AND 3D GRAPHIC STATICS IN DESIGN
    Hartz, C.
    Mazurek, A.
    Miki, M.
    Zegard, T.
    Mitchell, T.
    Baker, W. F.
    JOURNAL OF THE INTERNATIONAL ASSOCIATION FOR SHELL AND SPATIAL STRUCTURES, 2018, 59 (04): : 235 - 242
  • [44] The Research and Application of 2D and 3D Interactive System
    Sun, Yingjun
    Ding, Ning
    Hao, Guangrong
    Shi, Xingxi
    ICIC 2009: SECOND INTERNATIONAL CONFERENCE ON INFORMATION AND COMPUTING SCIENCE, VOL 2, PROCEEDINGS: IMAGE ANALYSIS, INFORMATION AND SIGNAL PROCESSING, 2009, : 252 - 254
  • [45] SHALLOW QUANTUM-WELL EXCITONS - 2D OR 3D
    BRENER, I
    KNOX, WH
    GOOSSEN, KW
    CUNNINGHAM, JE
    PHYSICAL REVIEW LETTERS, 1993, 70 (03) : 319 - 322
  • [46] Investigating differential expression of Palladin isoform 3 in 2D and 3D pancreatic cancer cell cultures
    Biswas, Sonali
    Bush, Jason A.
    CANCER RESEARCH, 2024, 84 (06)
  • [47] 2D and 3D on demand
    Philippi, Anne
    F & M; Feinwerktechnik, Mikrotechnik, Messtechnik, 1998, 106 (06): : 412 - 414
  • [48] 21/2D or 3D?
    Roth, S
    Küster, B
    Sura, H
    KUNSTSTOFFE-PLAST EUROPE, 2004, 94 (07): : 65 - 67
  • [49] Comparison of the impact of static and dynamic cultivation conditions on 2D and 3D cell cultures
    Pobis, P.
    Kubalcova, J.
    Milasova, T.
    Kand'arova, H.
    TOXICOLOGY LETTERS, 2023, 384 : S202 - S202
  • [50] Comparative Analysis of Dasatinib Effect between 2D and 3D Tumor Cell Cultures
    Sabetta, Samantha
    Vecchiotti, Davide
    Clementi, Letizia
    Nolfi, Mauro Di Vito
    Zazzeroni, Francesca
    Angelucci, Adriano
    PHARMACEUTICS, 2023, 15 (02)