Impact of Coronary Plaque Characteristics on Late Stent Malapposition after Drug-Eluting Stent Implantation

被引:3
|
作者
Hong, Sung-Jin [1 ]
Kim, Byeong-Keuk [2 ,3 ]
Shin, Dong-Ho [2 ,3 ]
Kim, Jung-Sun [2 ,3 ]
Ko, Young-Guk [2 ,3 ]
Choi, Donghoon [2 ,3 ]
Jang, Yangsoo [2 ,3 ,4 ]
Hong, Myeong-Ki [2 ,3 ,4 ]
机构
[1] Inje Univ, Coll Med, Sanggye Paik Hosp, Dept Internal Med,Div Cardiol, Seoul, South Korea
[2] Yonsei Univ, Coll Med, Severance Cardiovasc Hosp, Div Cardiol, Seoul 03722, South Korea
[3] Yonsei Univ, Coll Med, Cardiovasc Inst, Seoul 03722, South Korea
[4] Yonsei Univ, Coll Med, Severance Biomed Sci Inst, Seoul 03722, South Korea
关键词
Drug-eluting stent; intravascular ultrasound; optical coherence tomography; OPTICAL COHERENCE TOMOGRAPHY; INTRAVASCULAR ULTRASOUND ANALYSIS; ADVERSE CLINICAL-OUTCOMES; STRUT COVERAGE; FOLLOW-UP; APPOSITION; THROMBOSIS; PREDICTORS; MECHANISMS;
D O I
10.3349/ymj.2015.56.6.1538
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To evaluate the impact of pre-procedural coronary plaque composition assessed by virtual histology intravascular ultrasound (VH-IVUS) on late stent malapposition assessed by optical coherence tomography (OCT) following drug-eluting stent (DES) implantation. Materials and Methods: The study population consisted of 121 patients (121 lesions) who underwent both pre-procedural VH-IVUS and follow-up OCT after DES implantation. The association between pre-procedural plaque composition [necrotic core (NC), dense calcium (DC), fibrotic (FT), and fibro-fatty (FF) volumes] assessed by VH-IVUS and late stent malapposition (percent malapposed struts) or strut coverage (percent uncovered struts) assessed by follow-up OCT was evaluated. Results: Pre-procedural absolute total NC, DC, FT, and FF plaque volumes were 22.9 +/- 19.0, 7.9 +/- 9.6, 63.8 +/- 33.8, and 16.5 +/- 12.4 mm(3), respectively. At 6.3 +/- 3.1 months post-intervention, percent malapposed and uncovered struts were 0.8 +/- 2.5% and 15.3 +/- 16.7%, respectively. Pre-procedural absolute total NC and DC plaque volumes were positively correlated with percent malapposed struts (r=0.44, p<0.001 and r=0.45, p<0.001, respectively), while pre-procedural absolute total FT plaque volume was weakly associated with percent malapposed struts (r=0.220, p=0.015). Pre-procedural absolute total DC plaque volume was the only independent predictor of late stent malapposition on multivariate analysis (beta=1.12, p=0.002). There were no significant correlations between pre-intervention plaque composition and percent uncovered struts. Conclusion: Pre-procedural plaque composition was associated with late stent malapposition but not strut coverage after DES implantation. Larger pre-procedural absolute total DC plaque volumes were associated with greater late stent malapposition.
引用
收藏
页码:1538 / 1544
页数:7
相关论文
共 50 条
  • [21] Incidences, Predictors, and Clinical Outcomes of Acute and Late Stent Malapposition Detected by Optical Coherence Tomography After Drug-Eluting Stent Implantation
    Im, Eui
    Kim, Byeong-Keuk
    Ko, Young-Guk
    Shin, Dong-Ho
    Kim, Jung-Sun
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (01) : 88 - 96
  • [22] Morphologic characteristics of late stent malapposition after drug-eluting stents implantation by optical coherence tomography follow-up
    HOU Jing-bo
    Key Laboratories of Education Ministry for Myocardial Ischemia Mechanism and Treatment
    中华医学杂志(英文版), 2010, (05) : 581 - 584
  • [23] Morphologic characteristics of late stent malapposition after drug-eluting stents implantation by optical coherence tomography follow-up
    Hou Jing-bo
    Liu Hui-min
    Ma Li-jia
    Yang Shuang
    Meng Ling-bo
    Han Zhi-gang
    Zhang Shuo
    Yu Bo
    CHINESE MEDICAL JOURNAL, 2010, 123 (05) : 581 - 584
  • [24] Development of coronary aneurysm after drug-eluting stent implantation
    Bavry, Anthony A.
    Chin, John H.
    Jeflerson, Brian K.
    Karha, Juhana
    Bhatt, Deepak L.
    Ellis, Stephen G.
    Whitlow, Patrick L.
    ANNALS OF INTERNAL MEDICINE, 2007, 146 (03) : 230 - 232
  • [25] Late stent malapposition after drug-eluting stent implantation - An intravascular ultrasound analysis with long-term follow-up
    Hong, MK
    Mintz, GS
    Lee, CW
    Park, DW
    Park, KM
    Lee, BK
    Kim, YH
    Song, JM
    Han, KH
    Kang, DH
    Cheong, SS
    Song, JK
    Kim, JJ
    Park, SW
    Park, SJ
    CIRCULATION, 2006, 113 (03) : 414 - 419
  • [26] Long-Term Clinical Outcomes of Late Stent Malapposition Detected by Optical Coherence Tomography After Drug-Eluting Stent Implantation
    Im, Eui
    Hong, Sung-Jin
    Ahn, Chul-Min
    Kim, Jung-Sun
    Kim, Byeong-Keuk
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2019, 8 (07):
  • [27] Impact of late drug-eluting stent malapposition on 3-year clinical events
    Hong, Myeong-Ki
    Mintz, Gary S.
    Lee, Cheol Whan
    Park, Duk-Woo
    Lee, Seung-Whan
    Kim, Young-Hak
    Kang, Duk-Hyun
    Cheong, Sang-Sig
    Song, Jae-Kwan
    Kim, Jae-Joong
    Park, Seong-Wook
    Park, Seung-Jung
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (15) : 1515 - 1516
  • [28] Very late stent thrombosis in-late stent malapposition after sirohmus-eluting stent implantation
    Zhang, Feng
    Qian, Juying
    Ge, Junbo
    INTERNATIONAL HEART JOURNAL, 2007, 48 (05) : 591 - 596
  • [29] Clinical implications of in-stent late loss after drug-eluting stent implantation
    Moreno, R.
    Fernandez, C.
    Hernandez, R.
    Alfonso, F.
    Banuelos, C.
    Escaned, J.
    Fernandez-Ortiz, A.
    Macaya, C.
    EUROPEAN HEART JOURNAL, 2006, 27 : 655 - 655
  • [30] ACUTE RECOIL AND LATE RECOIL AFTER ORSIRO CORONARY DRUG-ELUTING STENT IMPLANTATION
    Sato, Takao
    Aizawa, Yoshifusa
    Taya, Yuji
    Ohta, Yusuke
    Yuasa, Sho
    Takahashi, Minoru
    Okabe, Masaaki
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 1142 - 1142