Fundamental information content accessible with medical x-ray scatter imaging

被引:9
|
作者
Leclair, RJ [1 ]
Johns, PC [1 ]
机构
[1] Carleton Univ, Dept Phys, Ottawa, ON K1S 5B6, Canada
关键词
x-ray scatter imaging; coherent scatter; Compton scatter; contrast; signal-to-noise ratio (SNR); spectral blur; experimental apparatus;
D O I
10.1117/12.349547
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Although scattered radiation is generally regarded as a nuisance in radiological imaging, many innovative imaging concepts that use the scattered field have been demonstrated. A systematic approach, however, for analyzing the medical applications of x-ray scatter imaging has been lacking. We have therefore formulated a simple semi-analytic model that consists of imaging a target object against a background material of the same dimensions when both are situated within a water phantom. The target and background objects have small cross-sectional areas (1.0 mm(2)) to allow the omission of self-attenuation and multiple scatter within the objects. The incident energy fluence is kept constant so that similar doses are delivered by the various photon beams. For imaging white brain matter versus gray brain matter in a 15 cm thick water phantom, the maximum signal-to-noise ratio, over all photon energies, for images obtained with the forward scatter between 2 degrees - 12 degrees exceeds that of primary images for all object thicknesses less than or equal to 40 mm. The penalty in dose as a result of spectral blur is generally moderate. For example, using an 80 kV beam for the previous imaging task would require approximately a 24% dose increase relative to using a monoenergetic beam. A high-precision experimental apparatus has been assembled to validate our predictions.
引用
收藏
页码:672 / 681
页数:10
相关论文
共 50 条
  • [21] X-RAY IMAGING WITH COMPTON-SCATTER RADIATION.
    Harding, G.
    Strecker, H.
    Tischler, R.
    Philips Technical Review, 1983, 41 (02): : 46 - 59
  • [22] The principles and effectiveness of X-ray scatter correction software for diagnostic X-ray imaging: A scoping review
    Sayed, Mohammad
    Knapp, Karen M.
    Fulford, Jon
    Heales, Christine
    Alqahtani, Saeed J.
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 158
  • [23] On the information content of X-ray diffraction data
    Read, Randy J.
    Oeffner, Robert D.
    Joosten, Robbie P.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2018, 74 : A301 - A301
  • [24] X-ray computed tomography for medical imaging
    Hiriyannaiah, HP
    IEEE SIGNAL PROCESSING MAGAZINE, 1997, 14 (02) : 42 - 59
  • [25] Optimisation strategies in medical X-ray imaging
    Mattsson, S
    RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 1 - 3
  • [26] X-ray medical imaging - A centennial perspective
    Sprawls, P
    PHYSICA MEDICA, 1997, 13 : 193 - 196
  • [27] Comment on "Perspectives of medical X-ray imaging"
    Taibi, A
    Baldelli, P
    Tuffanelli, A
    Gambaccini, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 487 (03): : 685 - 687
  • [28] Emerging Nanoagents for Medical X-ray Imaging
    Wu, Qinxia
    Zheng, Qianyu
    He, Yu
    Chen, Qiushui
    Yang, Huanghao
    ANALYTICAL CHEMISTRY, 2023, 95 (01) : 33 - 48
  • [29] X-Ray Tubes in Medical Imaging Applications
    Fuerst, Jens
    VAKUUM IN FORSCHUNG UND PRAXIS, 2015, 27 (05) : 17 - 21
  • [30] X-RAY COMPTON SCATTER IMAGING USING A HIGH-SPEED FLYING SPOT X-RAY TUBE
    TOWE, BC
    JACOBS, AM
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1981, 28 (10) : 717 - 721