In vivo second harmonic generation and ex vivo coherent anti-Stokes Raman scattering imaging of dermal collagen morphology and size of adipocytes in diet-induced obesity

被引:0
|
作者
Haluszka, D. [1 ]
Lorincz, K. [1 ]
Szipocs, R. [2 ]
Marton, D. [1 ]
Karpati, S. [1 ]
Wikonkal, N. M. [1 ]
机构
[1] Semmelweis Univ, Dermatol Venerol & Dermatooncol, H-1085 Budapest, Hungary
[2] Inst Solid State Phys & Opt Wigner RCP, Budapest, Hungary
关键词
D O I
暂无
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
487
引用
收藏
页码:S84 / S84
页数:1
相关论文
共 39 条
  • [21] Longitudinal, 3D In Vivo Imaging of Sebaceous Glands by Coherent Anti-Stokes Raman Scattering Microscopy: Normal Function and Response to Cryotherapy
    Jung, Yookyung
    Tam, Joshua
    Jalian, H. Ray
    Anderson, R. Rox
    Evans, Conor L.
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2015, 135 (01) : 39 - 44
  • [22] Investigation of the effect of hydration on dermal collagen in ex vivo human skin tissue using Second Harmonic Generation Microscopy
    Samatham, Ravikant
    Wang, Nicholas K.
    Jacques, Steven L.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS XII, 2016, 9689
  • [23] Ex vivo and in vivo second-harmonic-generation imaging of dermal collagen fiber in skin: comparison of imaging characteristics between mode-locked Cr:forsterite and Ti:sapphire lasers
    Yasui, Takeshi
    Takahashi, Yu
    Ito, Masahiro
    Fukushima, Shuichiro
    Araki, Tsutomu
    APPLIED OPTICS, 2009, 48 (10) : D88 - D95
  • [24] Generation of dark hollow beams used in sub-diffraction-limit imaging in coherent anti-Stokes Raman scattering microscopy
    Liu Shuang-Long
    Liu Wei
    Chen Dan-Ni
    Niu Han-Ben
    ACTA PHYSICA SINICA, 2014, 63 (21)
  • [25] Intracellular vacuoles induced by hypo-osmotic stress visualized by coherent anti-Stokes Raman scattering (CARS) spectroscopic imaging
    Hu, Zuliang
    Shirane, Kyota
    Aramaki, Kota
    Leproux, Philippe
    Inoko, Akihito
    Kano, Hideaki
    Matsushima, Ayami
    APPLIED PHYSICS EXPRESS, 2024, 17 (09)
  • [26] In vivo lipid saturation study of C. elegans using quantitative broadband coherent anti-Stokes Raman imaging (Conference Presentation)
    Littleton, Bradley
    Kavanagh, Thomas
    Nie, Yu
    Abbate, Vincenzo
    Hylands, Peter
    Sturzenbaum, Stephen
    Richards, David R.
    MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES XVI, 2016, 9712
  • [27] Label-free tetra-modal molecular imaging of living cells with CARS, SHG, THG and TSFG (coherent anti-Stokes Raman scattering, second harmonic generation, third harmonic generation and third-order sum frequency generation)
    Segawa, Hiroki
    Okuno, Masanari
    Kano, Hideaki
    Leproux, Philippe
    Couderc, Vincent
    Hamaguchi, Hiro-o
    OPTICS EXPRESS, 2012, 20 (09):
  • [28] Multimodal Multiphoton Imaging of the Lipid Bilayer by Dye-Based Sum-Frequency Generation and Coherent Anti-Stokes Raman Scattering
    Mizuguchi, Takaha
    Momotake, Atsuya
    Hishida, Mafumi
    Yasui, Masato
    Yamamoto, Yasuhiko
    Saiki, Toshiharu
    Nuriya, Mutsuo
    ANALYTICAL CHEMISTRY, 2020, 92 (08) : 5656 - 5660
  • [29] Hybrid femtosecond/picosecond rotational coherent anti-Stokes Raman scattering at flame temperatures using a second-harmonic bandwidth-compressed probe
    Kearney, Sean P.
    Scoglietti, Daniel J.
    OPTICS LETTERS, 2013, 38 (06) : 833 - 835
  • [30] Molecular identification of second harmonic generation (SHG) sources in mouse brain by multimodal imaging with ultra-broadband multiplex coherent anti Stokes Raman scattering (CARS)
    Murakami, Yusuke
    Oketani, Ryosuke
    Leproux, Philippe
    Nuriya, Mutsuo
    Honjoh, Sakiko
    Kano, Hideaki
    ADVANCED CHEMICAL MICROSCOPY FOR LIFE SCIENCE AND TRANSLATIONAL MEDICINE 2024, 2024, 12855