Would Nitric Oxide be an Effective Marker for Earlier Stages of Peri-Implant Disease? An Analysis in Human Peri-Implant Sulcular Fluid

被引:3
|
作者
Vieira, Andreia Espindola [1 ]
Gomes Moura, Camilla Christian [1 ]
de Souza, Maria Aparecida [1 ]
Zanetta-Barbosa, Darceny [1 ]
Dechichi, Paula [1 ]
机构
[1] Univ Fed Uberlandia, BR-38400 Uberlandia, MG, Brazil
关键词
dental implant; diagnosis; peri-implant sulcular fluid; peri-implant mucositis; nitrite; ENDOSSEOUS DENTAL IMPLANTS; IMAGE-BASED MEASURES; PERIODONTAL-DISEASE; CREVICULAR FLUID; BONE LOSS; METABOLISM; STABILITY; SALIVA; TEETH; MYELOPEROXIDASE;
D O I
10.1563/AAID-JOI-D-11-00158
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Nitric oxide has an important effect on host immune response. However, little has been studied in relation to its potential as a possible diagnostic tool in peri-implant disease. The present study analyzed nitrite levels in the peri-implant sulcular fluid (PISF) of implants with mucositis and the correlation of these nitrite levels with clinical parameters using a simplified fluid collection methodology. Twenty-five partially edentulous patients showing peri-implant mucositis were evaluated, and the peri-implant status was determined based on current clinical parameters: probing depth (PD) and bleeding on probing (BOP). The sulcular fluid (SF) around teeth (control) and implants were collected, and the nitrite levels were evaluated using the Griess method. The mean probing depth (mm) was significantly higher (P < .0001) in implants (2.852 +/- 0.6484) than in control teeth (1.585 +/- 0.3636). The mean total nitrite level (mu M) was statistically higher (P = .0069) in implants with mucositis (14.34 +/- 11.83) than in control teeth (9.316 +/- 5.534). No correlation was observed between the total nitrite levels and the PD mean in the control group (P = .2558, r = -0.2361) or in the implant group (P = .1160, r = -0.3224), as well as the number of faces showing bleeding on probing (P = .8747, r = 0.0332). These results demonstrated that the nitrite levels were higher in inflamed areas. According to the methodology applied and results obtained, the higher nitrite levels in inflamed areas suggest that, in the future, nitrite could be used as a marker of peri-implant mucositis associated with clinical data to monitor the cure or evolution of the disease.
引用
收藏
页码:37 / 43
页数:7
相关论文
共 50 条
  • [41] Changes in Inflammatory Mediators in Peri-Implant Fluid After Implant Insertion
    Venza, Mario
    Visalli, Maria
    Lo Giudice, Giuseppe
    Cicciu, Marco
    Passi, Pietro
    Teti, Diana
    JOURNAL OF PERIODONTOLOGY, 2009, 80 (02) : 297 - 306
  • [42] Microcomputed tomographic analysis of the peri-implant bone
    Rebaudi, A
    Koller, B
    Laib, A
    Trisi, P
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2004, 24 (04) : 317 - +
  • [43] Peri-implant crevicular fluid SIRT1 levels decrease in patients with peri-implant inflammatory: A prospective observational study
    Wang, Zhuo
    TRANSPLANT IMMUNOLOGY, 2022, 74
  • [44] Does peri-implant bone loss affect the LL-37 and proteinase 3 levels in peri-implant sulcus fluid?
    Oya Turkoglu
    Candan Efeoglu
    Harika Atmaca
    International Journal of Implant Dentistry, 6
  • [45] CrossLaps and β-glucuronidase in peri-implant and gingival crevicular fluid
    Schubert, U
    Kleber, BM
    Strietzel, FP
    Dörfling, P
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2001, 16 (02) : 252 - 258
  • [46] Effect of Amniotic Fluid on Peri-implant Capsular Formation
    Naci Karaçal M.D.
    Ümit Çobanoğlu
    Ömer Ambarcioğlu
    Umut Topal
    Necmettin Kutlu
    Aesthetic Plastic Surgery, 2005, 29 : 174 - 180
  • [47] Stability analysis for a peri-implant osseointegration model
    Pavel Prokharau
    Fred Vermolen
    Journal of Mathematical Biology, 2013, 66 : 351 - 382
  • [48] Effect of amniotic fluid on peri-implant capsular formation
    Karaçal, N
    Çobanoglu, Ü
    Ambarcioglu, Ö
    Topal, U
    Kutlu, N
    AESTHETIC PLASTIC SURGERY, 2005, 29 (03) : 174 - 180
  • [49] Stability analysis for a peri-implant osseointegration model
    Prokharau, Pavel
    Vermolen, Fred
    JOURNAL OF MATHEMATICAL BIOLOGY, 2013, 66 (1-2) : 351 - 382
  • [50] Does peri-implant bone loss affect the LL-37 and proteinase 3 levels in peri-implant sulcus fluid?
    Turkoglu, Oya
    Efeoglu, Candan
    Atmaca, Harika
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)