Effect of Decentration on the Optical Quality of Monofocal, Extended Depth of Focus, and Bifocal Intraocular Lenses

被引:35
|
作者
Xu, Jie [1 ,2 ,3 ,4 ]
Zheng, Tianyu [1 ,2 ,3 ,4 ]
Lu, Yi [1 ,2 ,3 ,4 ]
机构
[1] Fudan Univ, Eye & Ear Nose & Throat Hosp, Dept Ophthalmol, Shanghai, Peoples R China
[2] Fudan Univ, Eye & Ear Nose & Throat Hosp, Eye Inst, Shanghai, Peoples R China
[3] Minist Hlth, Key Lab Myopia, Shanghai, Peoples R China
[4] Shanghai Key Lab Visual Impairment & Restorat, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
TILT; PERFORMANCE; RANGE;
D O I
10.3928/1081597X-20190708-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the effect of intraocular lens (IOL) decentration on the optical quality in patients with implantation of three IOLs: monofocal, extended depth of focus (EDOF), and bifocal. METHODS: Patients had cataract surgery with implantation of one of the three above-mentioned IOLs. Higher order aberrations (HOAs), modulation transfer function (MTF), point spread function (PSF), retinal straylight, and dysphotopsia phenomena were evaluated 3 months after surgery. IOL decentration was quantified as the distance between the visual axis center and the IOL center using the OPD-Scan III aberrometer (Nidek Co., Ltd., Gamagori, Japan). The patients who received each IOL type were then divided into two subgroups (decentration of <= 0.25 or > 0.25 mm) to analyze the effect of IOL decentration on these optical qualities. RESULTS: The study included 54 eyes (54 patients), with 18 eyes in each IOL group. The distance of IOL decentration did not differ significantly among the three groups. With a decentration of more than 0.25 mm, MTF, PSF, and coma were only significantly deteriorated in the bifocal IOL (ZMB00; Abbott Medical Optics, Santa Ana, CA). HOAs, coma, PSF, and glare perception were better in the monofocal and EDOF IOLs than those in the ZMB00 IOL when decentration was more than 0.25 mm. Furthermore, IOL decentration was significantly correlated with HOAs, coma, MTF, and PSF in the ZMB00 IOL. CONCLUSIONS: The monofocal and EDOF IOLs are more immune to optical quality degradation caused by IOL decentration than the ZMB00 IOL.
引用
收藏
页码:484 / +
页数:10
相关论文
共 50 条
  • [31] Depth of focus in eyes with diffractive bifocal and refractive multifocal intraocular lenses
    Schmidinger, Gerald
    Geitzenauer, Wolfgang
    Hahsle, Bernhard
    Klemen, Ulrich-Michael
    Skorpik, Christian
    Pieh, Stefan
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (10): : 1650 - 1656
  • [32] Laboratory Evaluation of the Influence of Decentration and Pupil Size on the Optical Performance of a Monofocal, Bifocal, and Trifocal Intraocular Lens
    Tandogan, Tamer
    Son, Hyeck Soo
    Choi, Chul Young
    Knorz, Michael C.
    Auffarth, Gerd U.
    Khoramnia, Ramin
    JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (12) : 808 - +
  • [33] EFFECT OF PUPIL SIZE AND ASTIGMATISM ON CONTRAST ACUITY WITH MONOFOCAL AND BIFOCAL INTRAOCULAR LENSES
    KNORZ, MC
    KOCH, DD
    MARTINEZFRANCO, C
    LORGER, CV
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 (01): : 26 - 33
  • [34] Current Review: Multifocal Intraocular Lenses and Extended Depth of Focus Intraocular Lenses
    Breyer, Detlev R. H.
    Beckers, Lena
    Ax, Timon
    Kaymak, Hakan
    Klabe, Karsten
    Kretz, Florian Tobias Alwin
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2020, 237 (08) : 943 - 957
  • [35] The effect of trifocal and extended-depth-of-focus intraocular lenses on optical coherence tomography parameters
    Sezenoz, Almila Sarigul
    Gungor, Sirel Gur
    Dogan, Irem Kirci
    Colak, Meric Yavuz
    Gokgoz, Gulsah
    Altinors, Dilek Dursun
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (SUPPL 3) : S423 - S428
  • [36] Effect of blocking violet light in extended depth of focus intraocular lenses
    Faria-Ribeiro, Miguel
    Jenkins, Mark
    Rosen, Robert
    van der Mooren, Marrie
    Canovas, Carmen
    Piers, Patricia
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [37] Effect of Decentration on the Optical Performance in Multifocal Intraocular Lenses
    Soda, Mitsutaka
    Yaguchi, Shigeo
    OPHTHALMOLOGICA, 2012, 227 (04) : 197 - 204
  • [38] Refraction, anterior chamber depth, decentration, and tilt after implantation of monofocal and multifocal silicone intraocular lenses
    Dick, HB
    Schwenn, O
    Krummenauer, F
    Weidler, S
    Pfeiffer, N
    OPHTHALMOLOGE, 2001, 98 (04): : 380 - 386
  • [39] Comparative analysis of a presbyopia-correcting intraocular lens that combines extended depth-of-focus and bifocal profiles with a standard monofocal intraocular lens
    Shin, Da Eun
    Lee, Hun
    Koh, Kyungmin
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [40] Depth of focus extended intraocular lenses and their optical performances in a pseudophakic eye model
    Wang, Zhao-Qi
    Rao, Feng
    Liu, Yong-Ji
    5TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: ADVANCED OPTICAL MANUFACTURING TECHNOLOGIES, 2010, 7655