Indium phosphide all air-gap Fabry-Perot filters for near-infrared spectroscopic applications

被引:2
|
作者
Ullah, A. [1 ]
Butt, M. A. [2 ]
Fomchenkov, S. A. [2 ,3 ]
Khonina, S. N. [2 ,3 ]
机构
[1] BUITEMS, Dept Elect Engn, Takatu Campus,Airport Rd, Quetta 87300, Pakistan
[2] Samara State Aerosp Univ, Moskovskoye Shosse 34, Samara 443086, Russia
[3] Russian Acad Sci, Image Proc Syst Inst, Molodogvardeyshaya 151, Samara 443001, Russia
关键词
WATER-HOLDING CAPACITY;
D O I
10.1088/1742-6596/741/1/012135
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Food quality can be characterized by noninvasive techniques such as spectroscopy in the Near Infrared wavelength range. For example, 930-1450 nm wavelength range can be used to detect diseases and differentiate between meat samples. Miniaturization of such NIR spectrometers is useful for quick and mobile characterization of food samples. Spectrometers can be miniaturized, without compromising the spectral resolution, using Fabry-Perot (FP) filters consisting of two highly reflecting mirrors with a central cavity in between. The most commonly used mirrors in the design of FP filters are Distributed Bragg Reflections (DBRs) consisting of alternating high and low refractive index material pairs, due to their high reflectivity compared to metal mirrors. However, DBRs have high reflectivity for a selected range of wavelengths known as the stopband of the DBR. This range is usually much smaller than the sensitivity range of the spectrometer detector. Therefore, a bandpass filter is usually required to restrict wavelengths outside the stopband of the FP DBRs. Such bandpass filters are difficult to design and implement. Alternatively, high index contrast materials must be can be used to broaden the stopband width of the FP DBRs. In this work, Indium phosphide all air-gap filters are proposed in conjunction with InGaAs based detectors. The designed filter has a wide stopband covering the entire InGaAs detector sensitivity range. The filter can be tuned in the 950-1450 nm with single mode operation. The designed filter can hence be used for noninvasive meat quality control.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] HIGH-SPATIAL-RESOLUTION FABRY-PEROT IMAGING OF M82 - NEAR-INFRARED RECOMBINATION LINE OBSERVATIONS
    SATYAPAL, S
    WATSON, DM
    PIPHER, JL
    FORREST, WJ
    COPPENBARGER, D
    RAINES, SN
    LIBONATE, S
    PICHE, F
    ASTROPHYSICAL JOURNAL, 1995, 448 (02): : 611 - 622
  • [42] TUNABLE BROADBAND MEMS FABRY-PEROT NEAR INFRARED FILTER BASED ON DOUBLE-MEMBRANE SILICON/AIR MIRRORS
    Kraemmer, Christoph
    Roedel, Reinhold
    Huber, Christian
    Schmid, Marc
    Buck, Thomas
    2019 20TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS & EUROSENSORS XXXIII (TRANSDUCERS & EUROSENSORS XXXIII), 2019, : 1522 - 1525
  • [43] Theoretical Investigation of Near-Infrared Fabry-Perot Microcavity Graphene/Silicon Schottky Photodetectors Based on Double Silicon on Insulator Substrates
    Casalino, Maurizio
    MICROMACHINES, 2020, 11 (08)
  • [44] Development of Near-Infrared Scanning Fabry-Perot Spectrometer for 3D spectroscopy : Design concept and basic performance evaluation
    Takahashi, Hidenori
    Maezawa, Hiroaki
    Hashiba, Hiroyuki
    Hoshino, Hidemi
    GROUND-BASED AND AIRBORNE INSTRUMENTATION FOR ASTRONOMY X, 2024, 13096
  • [45] NEAR-INFRARED OBSERVATIONS OF DUST COMA OF COMET KOHOUTEK (1973F) WITH A TILTING-FILTER FABRY-PEROT PHOTOMETER
    BARBIERI, C
    COSMOVICI, CB
    MICHEL, KW
    NISHIMURA, T
    ROCHE, AE
    ICARUS, 1974, 23 (04) : 568 - 576
  • [46] A Near-Infrared Multi-Band Perfect Absorber Based on 1D Gold Grating Fabry-Perot Structure
    Wu, Pinghui
    Wang, Yingying
    Yi, Zao
    Huang, Zhen
    Xu, Zhousu
    Jiang, Peipei
    IEEE ACCESS, 2020, 8 (08): : 72742 - 72748
  • [47] Air-gap Fabry-Perot cavity filtered 30 nm broadband electro-optic frequency combs for high-order coherent communications
    Zhang, Chenbo
    Zhu, Yixiao
    He, Bibo
    Liu, Rongwei
    Chen, Zhangyuan
    Hu, Weiwei
    Xie, Xiaopeng
    OPTICS LETTERS, 2022, 47 (15) : 3724 - 3727
  • [48] Design and simulation of the optical amplitude-shift keying modulator using Fabry-Perot resonator coupled with graphene at near-infrared frequencies
    Ghods, Mohammad Mahdi
    Afsahi, Majid
    JOURNAL OF NANOPHOTONICS, 2021, 15 (02)
  • [49] Dual-band tunable narrowband near-infrared light trapping control based on a hybrid grating-based Fabry-Perot structure
    Zhou, Kun
    Cheng, Qiang
    Lu, Lu
    Li, Bowen
    Song, Jinlin
    Luo, Zixue
    OPTICS EXPRESS, 2020, 28 (02) : 1647 - 1656
  • [50] A FABRY-PEROT IMAGER FOR NEAR-INFRARED ASTROPHYSICS AT THE COMMUNICATIONS-RESEARCH LABORATORY 1.5 METER TELESCOPE, AND IMAGING OF HYDROGEN RECOMBINATION LINES IN THE ORION NEBULA
    SUGAI, H
    USUDA, T
    KATAZA, H
    TANAKA, M
    KAWABATA, H
    INOUE, MY
    TAKAMI, H
    AOKI, T
    HIROMOTO, N
    ASTROPHYSICAL JOURNAL, 1994, 427 (01): : 511 - 518