Indium phosphide all air-gap Fabry-Perot filters for near-infrared spectroscopic applications

被引:2
|
作者
Ullah, A. [1 ]
Butt, M. A. [2 ]
Fomchenkov, S. A. [2 ,3 ]
Khonina, S. N. [2 ,3 ]
机构
[1] BUITEMS, Dept Elect Engn, Takatu Campus,Airport Rd, Quetta 87300, Pakistan
[2] Samara State Aerosp Univ, Moskovskoye Shosse 34, Samara 443086, Russia
[3] Russian Acad Sci, Image Proc Syst Inst, Molodogvardeyshaya 151, Samara 443001, Russia
关键词
WATER-HOLDING CAPACITY;
D O I
10.1088/1742-6596/741/1/012135
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Food quality can be characterized by noninvasive techniques such as spectroscopy in the Near Infrared wavelength range. For example, 930-1450 nm wavelength range can be used to detect diseases and differentiate between meat samples. Miniaturization of such NIR spectrometers is useful for quick and mobile characterization of food samples. Spectrometers can be miniaturized, without compromising the spectral resolution, using Fabry-Perot (FP) filters consisting of two highly reflecting mirrors with a central cavity in between. The most commonly used mirrors in the design of FP filters are Distributed Bragg Reflections (DBRs) consisting of alternating high and low refractive index material pairs, due to their high reflectivity compared to metal mirrors. However, DBRs have high reflectivity for a selected range of wavelengths known as the stopband of the DBR. This range is usually much smaller than the sensitivity range of the spectrometer detector. Therefore, a bandpass filter is usually required to restrict wavelengths outside the stopband of the FP DBRs. Such bandpass filters are difficult to design and implement. Alternatively, high index contrast materials must be can be used to broaden the stopband width of the FP DBRs. In this work, Indium phosphide all air-gap filters are proposed in conjunction with InGaAs based detectors. The designed filter has a wide stopband covering the entire InGaAs detector sensitivity range. The filter can be tuned in the 950-1450 nm with single mode operation. The designed filter can hence be used for noninvasive meat quality control.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Monolithic Integration of a Tunable Photodetector Based on InP/air-gap Fabry-Perot Filters
    Kusserow, Thomas
    Zamora, Ricardo
    Sonksen, Julian
    Dharmarasu, Nethaji
    Hillmer, Hartmut
    Nakamura, Tetsuji
    Hayakawa, Tetsuo
    Vengatesan, Balasubramanian
    2008 IEEE/LEOS INTERNATIONAL CONFERENCE ON OPTICAL MEMS AND NANOPHOTONICS, 2008, : 134 - +
  • [2] A FABRY-PEROT SPECTROMETER FOR NEAR-INFRARED ASTRONOMICAL OBSERVATIONS
    TANAKA, M
    YAMASHITA, T
    SATO, S
    OKUDA, H
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 1985, 97 (596) : 1020 - 1025
  • [3] FAST - A NEAR-INFRARED IMAGING FABRY-PEROT SPECTROMETER
    KRABBE, A
    ROTACIUC, V
    STOREY, JWV
    CAMERON, M
    BLIETZ, M
    DRAPATZ, S
    HOFMANN, R
    SAMANN, G
    GENZEL, R
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 1993, 105 (694) : 1472 - 1481
  • [4] Ultrasensitive Microtaper with an Air-gap Microcavity Fiber Fabry-Perot Interferometer
    Tai, Ching-Yi
    Chen, Chien-Lin
    Han, Pin
    Lee, Cheng-Ling
    2013 CONFERENCE ON LASERS AND ELECTRO-OPTICS PACIFIC RIM (CLEO-PR), 2013,
  • [5] Adiabatic fiber microtaper with incorporated an air-gap microcavity fiber Fabry-Perot interferometer
    Lee, Cheng-Ling
    Tai, Ching-Yi
    Chen, Chien-Lin
    Han, Pin
    APPLIED PHYSICS LETTERS, 2013, 103 (03)
  • [6] Near-Infrared Camera and Fabry-Perot Spectrometer - NIC-FPS
    Vincent, MB
    Morse, JA
    Beland, S
    Hearty, F
    Bally, J
    Ellingson, E
    Wilkinson, E
    Hartigan, P
    Holtzman, J
    Barentine, J
    INSTRUMENT DESIGN AND PERFORMANCE FOR OPTICAL/INFRARED GROUND-BASED TELESCOPES, PTS 1-3, 2003, 4841 : 367 - 375
  • [7] Tunable double membrane MEMS Fabry-Perot interferometers for the near-infrared
    Huber, Christian
    Kraemmer, Christoph
    Stein, Benedikt
    Kalt, Heinz
    2018 INTERNATIONAL CONFERENCE ON OPTICAL MEMS AND NANOPHOTONICS (OMN), 2018, : 193 - 194
  • [8] Near-Infrared Camera and Fabry-Perot Spectrometer (NIC-FPS)
    Hearty, F
    Morse, J
    Beland, S
    Green, J
    Cunningham, N
    Valentine, R
    Drosback, M
    Froning, C
    Hartigan, P
    Barentine, J
    GROUND-BASED INSTRUMENTATION FOR ASTRONOMY, PTS 1-3, 2004, 5492 : 1623 - 1632
  • [9] A near-infrared Fabry-Perot for Fourier-Transform spectrograph calibration
    Debus, M.
    Schafer, S.
    Huke, P.
    Reiners, A.
    GROUND-BASED AND AIRBORNE INSTRUMENTATION FOR ASTRONOMY IX, 2022, 12184
  • [10] INTERFERENCE METHODS FOR MEASUREMENTS OF RADIAL VELOCITIES .2. AIR-GAP AND ALL-GLASS FABRY-PEROT ETALONS
    GEORGELIN, YP
    ASTRONOMY & ASTROPHYSICS, 1970, 9 (03): : 436 - +