Thermodynamic analysis of the performance of a solar absorption heat transformer at maximum coefficient of performance

被引:0
|
作者
Chen, JC
机构
[1] Department of Physics, Xiamen University
关键词
absorption heat transformer; solar collector; heat transfer; coefficient of performance; optimal analysis;
D O I
10.1002/(SICI)1099-114X(199709)21:11<975::AID-ER298>3.0.CO;2-W
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
It is proven that a solar absorption heat transformer affected by the irreversibility of finite-rate heat transfer may be modelled as an equivalent combined system consisting of a solar collector and an endoreversible absorption heat transformer, the latter being further treated as a combined cycle having an endoreversible heat pump driven by an endoreversible heat engine. The maximum coefficient of performance of the system is determined, based on the linear heat loss model for solar collectors and the general optimum relation for endoreversible absorption heat transformers. The optimality problems concerning the primary performance parameters of the system are discussed. The results obtained here may serve as a good guide for the evaluation of existing real solar absorption heat transformers or provide some theoretical bases for the optimal design of future solar absorption heat transformers. (C) 1997 by John Wiley & Sons, Ltd.
引用
收藏
页码:975 / 984
页数:10
相关论文
共 50 条
  • [21] OPTIMAL CHOICE OF THE PERFORMANCE PARAMETERS OF AN ABSORPTION HEAT TRANSFORMER
    CHEN, JC
    HEAT RECOVERY SYSTEMS & CHP, 1995, 15 (03): : 249 - 256
  • [22] Experimental performance of ternary solutions in an absorption heat transformer
    Barragan, RM
    Arellano, VM
    Heard, CL
    Best, R
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1998, 22 (01) : 73 - 83
  • [23] PERFORMANCE ANALYSIS OF A VAPOR ABSORPTION HEAT TRANSFORMER WITH DIFFERENT WORKING FLUID COMBINATIONS
    KRIPALANI, VM
    MURTHY, SS
    MURTHY, MVK
    JOURNAL OF HEAT RECOVERY SYSTEMS, 1984, 4 (03): : 129 - 140
  • [24] Performance analysis of a dual component evaporator-absorber of an absorption heat transformer
    Delgado-Gonzaga, J.
    Huicochea, A.
    Torres-Merino, J.
    Canela-Sanchez, I.
    Juarez-Romero, D.
    DESALINATION AND WATER TREATMENT, 2017, 73 : 175 - 184
  • [25] Effect of irreversibilities on performance of an absorption heat transformer used to increase solar pond's temperature
    Sözen, A
    RENEWABLE ENERGY, 2004, 29 (04) : 501 - 515
  • [26] Studies on thermodynamic performance of three stage sorption heat transformer
    Mohan, Man
    Sharma, Vinod Kumar
    APPLIED THERMAL ENGINEERING, 2019, 154 : 228 - 237
  • [27] Adiabatic Absorption by Absorbent Atomization for Improving Absorption Heat Transformer Performance
    Evron, Yigal
    Gommed, Khaled
    Grossman, Gershon
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2020, 142 (05):
  • [28] Performance analysis on modified cycle of double absorption heat transformer with solution and coolant heat regeneration
    Ji, Guangju
    Chen, Yaping
    Wu, Jiafeng
    Ji, Ge
    APPLIED THERMAL ENGINEERING, 2016, 108 : 115 - 121
  • [29] Performance of an absorption heat-transformer with different heat transfer law
    Department of Power Engineering, Naval University of Engineering, Wuhan 430033, China
    Jixie Gongcheng Xuebao, 2006, 2 (12-17):
  • [30] Maximum coefficient of performance of internally irreversible refrigerators and heat pumps
    Ecole Nationale Polytechnique, Algeria
    J Phys D, 4 (975-980):