Development of a new multi-modal Monte-Carlo radiotherapy planning system

被引:6
|
作者
Kumada, H. [1 ,2 ]
Nakamura, T. [1 ,3 ]
Komeda, M. [1 ]
Matsumura, A. [2 ]
机构
[1] Japan Atom Energy Agcy, Dept Res Reactor & Tandem Accelerator, Tokai, Ibaraki, Japan
[2] Univ Tsukuba, Grad Sch Comprehens Human Sci, Tsukuba, Ibaraki, Japan
[3] Ibaraki Univ, Grad Sch Sci & Engn, Mito, Ibaraki, Japan
关键词
BNCT; Treatment planning; Monte-Carlo; Computational dosimetry; JRR-4; BNCT;
D O I
10.1016/j.apradiso.2009.03.028
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A new multi-modal Monte-Carlo radiotherapy planning system (developing code: JCDS-FX) is under development at Japan Atomic Energy Agency. This system builds on fundamental technologies of JCDS applied to actual boron neutron capture therapy (BNCT) trials in JRR-4. One of features of the JCDS-FX is that PHITS has been applied to particle transport calculation. PHITS is a multi-purpose particle Monte-Carlo transport code. Hence application of PHITS enables to evaluate total doses given to a patient by a combined modality therapy. Moreover, JCDS-FX with PHITS can be used for the study of accelerator based BNCT. To verify calculation accuracy of the JCDS-FX, dose evaluations for neutron irradiation of a cylindrical water phantom and for an actual clinical trial were performed, then the results were compared with calculations by JCDS with MCNP The verification results demonstrated that JCDS-FX is applicable to BNCT treatment planning in practical use. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S118 / S121
页数:4
相关论文
共 50 条
  • [31] Tools for integrating Monte Carlo dose engines with a radiotherapy planning system
    Schreiber, E.
    Tracton, G.
    Chaney, E.
    MEDICAL PHYSICS, 2006, 33 (06) : 2146 - 2146
  • [32] An integrated Monte Carlo dosimetric verification system for radiotherapy treatment planning
    Yamamoto, T.
    Mizowaki, T.
    Miyabe, Y.
    Takegawa, H.
    Narita, Y.
    Yano, S.
    Nagata, Y.
    Teshima, T.
    Hiraoka, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (07): : 1991 - 2008
  • [33] The parallelization of Monte-Carlo planning - Parallelization of MC-planning
    Gelly, S.
    Hoock, J. B.
    Rimmel, A.
    Teytaud, O.
    Kalemkarian, Y.
    ICINCO 2008: PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON INFORMATICS IN CONTROL, AUTOMATION AND ROBOTICS, VOL ICSO: INTELLIGENT CONTROL SYSTEMS AND OPTIMIZATION, 2008, : 244 - +
  • [34] SIMULATION OF MULTI-LEVEL-GRAIN DEVELOPMENT BY THE MONTE-CARLO METHOD
    INUI, M
    KIDA, A
    MIYAKE, Y
    KUBO, S
    JOURNAL OF IMAGING SCIENCE, 1985, 29 (06): : 226 - 228
  • [35] An overview of Monte Carlo treatment planning for radiotherapy
    Spezi, Emiliano
    Lewis, Geraint
    RADIATION PROTECTION DOSIMETRY, 2008, 131 (01) : 123 - 129
  • [36] Monte-Carlo simulation of proton radiotherapy for human eye
    Liu, Yun-Peng
    Tang, Xiao-Bin
    Xie, Qin
    Chen, Fei-Da
    Geng, Chang-Ran
    Chen, Da
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2010, 44 (SUPPL. 1): : 602 - 607
  • [37] Core structure-guided multi-modal classification via Monte Carlo Tree Search
    Liu, Guoqing
    Qian, Yuhua
    Liang, Xinyan
    Fu, Pinhan
    INTERNATIONAL JOURNAL OF MACHINE LEARNING AND CYBERNETICS, 2025,
  • [38] Monte-Carlo simulation of multi-agent system in soap froth
    Kong, CW
    Szeto, KY
    MODELLING AND SIMULATION 2002, 2002, : 343 - 345
  • [39] MONTE-CARLO ANALYSIS OF SYSTEM TOLERANCE
    DISTLER, RJ
    IEEE TRANSACTIONS ON EDUCATION, 1977, 20 (02) : 98 - 101
  • [40] Multi-modal medical image integration to optimize radiotherapy planning in lung cancer treatment
    Rizzo, G
    Cattaneo, GM
    Castellone, P
    Castiglioni, I
    Ceresoli, GL
    Messa, C
    Landoni, C
    Gilardi, MC
    Arienti, R
    Cerutti, S
    Fazio, F
    ANNALS OF BIOMEDICAL ENGINEERING, 2004, 32 (10) : 1399 - 1408