Mechanical Properties of Post-fire Inorganic Polymer Concrete Columns under Eccentric Compression

被引:0
|
作者
Chen, Huiguo [1 ]
Lei, Yixin [1 ]
Zhao, Yue [1 ]
机构
[1] Army Logist Univ PLA, Dept Mil Installat, Chongqing 401331, Peoples R China
关键词
inorganic polymer concrete (IPC); high temperature; eccentric compression; mechanical properties; GEOPOLYMER;
D O I
10.18280/rcma.290304
中图分类号
TB33 [复合材料];
学科分类号
摘要
This paper aims to disclose the variation law in the performance of inorganic polymer concrete (IPC) columns under varied temperatures. Therefore, the IPC columns were tested under eccentric compression at several high-temperature conditions, and multiple mechanical indices of each column were measured, including the compressive strength, axial deformation and lateral displacement. On this basis, the author analyzed the impacts of the high-temperature conditions on the mechanical properties of the IPC columns. The analysis shows that the compressive strength of the IPC columns was enhanced with the increase of fire temperature, and started to decline after the temperature surpassed 400 degrees C; the loss ratio, i.e. the loss of compressive strength, of each IPC column under eccentric load, was smaller than that of the corresponding ordinary concrete column, under any high-temperature condition. The research results confirm the excellent fire-resistance of the IPC, shedding new light on fire prevention and post-fire evaluation.
引用
收藏
页码:151 / 157
页数:7
相关论文
共 50 条
  • [21] Post-fire seismic behaviors of concrete stub columns in different fire exposure cases
    Xu Y.
    Chen Y.
    Yan B.
    Zheng Y.
    Luo Y.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2020, 39 (18): : 11 - 19
  • [22] Fire and post-fire performance of circular steel tube confined reinforced concrete columns
    Liu, F.
    Yang, H.
    Zhang, S.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018), 2018, : 787 - 793
  • [23] Axial Compression Performance of Post-Fire Concrete Columns Strengthened Using Thin-Walled Steel Tubes
    Luo, Yi
    Su, Jiapeng
    Xu, Yuye
    Ou, Tingru
    Peng, Xingqian
    SUSTAINABILITY, 2019, 11 (18)
  • [24] Post-fire behavior of unconfined and steel tube confined rubberized concrete under axial compression
    Bengar, Habib Akbarzadeh
    Shahmansouri, Amir Ali
    STRUCTURES, 2021, 32 : 731 - 745
  • [25] Post-fire Study on Mechanical Properties of Damaged Ultra-high Strength Concrete
    Xiao Lyu
    Guang-Hao Jia
    Gan-Ping Shu
    Xin Zhang
    Er-Feng Du
    Wen-Ming Wang
    International Journal of Steel Structures, 2022, 22 : 1918 - 1929
  • [26] Post-fire assessment of mechanical properties of concrete with the use of the impact-echo method
    Krzemien, Katarzyna
    Hager, Izabela
    CONSTRUCTION AND BUILDING MATERIALS, 2015, 96 : 155 - 163
  • [27] Post-fire Study on Mechanical Properties of Damaged Ultra-high Strength Concrete
    Lyu, Xiao
    Jia, Guang-Hao
    Shu, Gan-Ping
    Zhang, Xin
    Du, Er-Feng
    Wang, Wen-Ming
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2022, 22 (06) : 1918 - 1929
  • [28] Post-Fire Mechanical Properties of Concrete Incorporating Waste EPS (Styrofoam) as Aggregate Replacement
    Mohammed, Ilham I.
    Nariman, Nazim Abdul
    Shakor, Pshtiwan
    Ismail, Osama
    Rizgar, Kozhin
    CIVILENG, 2023, 4 (02): : 359 - 372
  • [29] Evaluation of mechanical properties and post-fire cured strength recovery of recycled aggregate concrete
    Suresh, N.
    Rao, Vadiraj
    Akshay, B. S.
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2022, 13 (04) : 491 - 505
  • [30] Fire performance and post-fire mechanical properties of polymer composites coated with hybrid carbon nanofiber paper
    Zhuge, Jinfeng
    Gou, Jihua
    Chen, Ruey-Hung
    Zhou, Aixi
    Yu, Ziqing
    JOURNAL OF APPLIED POLYMER SCIENCE, 2012, 124 (01) : 37 - 48