Experimental analysis on calibration of instrument broadening in a lidar system with Fabry-Perot etalon

被引:6
|
作者
Ma, Yong [1 ]
Li, Hao [1 ]
Yu, Yin [1 ]
Yao, Yuan [2 ]
Fang, Yu [1 ]
Zhou, Bo [1 ]
Huang, Jun [1 ]
Min, Jun [1 ]
Liang, Kun [1 ]
机构
[1] Huazhong Univ Sci & Technol, Elect & Informat Engn Dept, Wuhan 430074, Peoples R China
[2] Huazhong Univ Sci & Technol, Coll Publ Adm, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金; 高等学校博士学科点专项科研基金;
关键词
Rayleigh Brillouin scattering; lidar; Fabry-Perot etalon; high resolution spectrum; F-P ETALON; BRILLOUIN-SCATTERING; BULK VISCOSITY; EDGE TECHNIQUE; SOUND SPEED; TEMPERATURE; ATTENUATION; DEPENDENCE; FREQUENCY; LIQUID;
D O I
10.1080/09500340.2013.868552
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A Brillouin lidar system based on a Fabry-Perot (F-P) etalon and intensified charge coupled device (ICCD) is widely used in measuring ocean physical properties. In previous signal detecting methods, the resolution of the obtained Brillouin spectrum is the major limitation on measurement accuracy of the Brillouin spectrum. The effect due to the instrument of the F-P etalon is relatively minor and typically neglected. However, because methods for obtaining a high resolution spectrum have greatly improved the spectral resolution, the instrument broadening has become the major error source and should be taken into consideration in the measurement. Instrument broadening is a common topic and has been widely researched. Unfortunately, for applications involving a high resolution spectrum, no detailed study has analyzed the performance of the methods for calibrating the broadening with high resolution experimental data. In this paper, the capability and the time costs of methods for reducing the broadening effect are evaluated for a high resolution spectrum obtained from underwater experiments. We also discuss in detail the implementation of the methods. Experimental results show that the three methods considered can effectively calibrate the broadening effect and improve the measurement accuracy from tens of MHz to MHz magnitude. Considering the similar performance of the methods, one method that is sufficient for online measurement is recommended as the optimal method.
引用
收藏
页码:1968 / 1976
页数:9
相关论文
共 50 条
  • [21] A Technique for Wavelength Calibration of a Multichannel Polychromator Spectrometer Using the Fabry-Perot Etalon
    Shabashov, A. Yu.
    Serov, S. V.
    Tugarinov, S. N.
    Yartsev, V. P.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2019, 62 (05) : 675 - 678
  • [22] Fast calibration parameters of Fabry-Perot etalon by laser linear frequency sweep
    An, Panlong
    Zhao, Ruijuan
    Liu, Zhengguang
    Zhang, Xufeng
    Li, Yijun
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2015, 44 (11): : 3418 - 3422
  • [23] TUNING PROPERTIES OF A BIREFRINGENT FABRY-PEROT ETALON
    FROLICH, D
    WELLING, H
    APPLIED PHYSICS, 1976, 9 (03): : 205 - 207
  • [24] Tuneable Fabry-Perot etalon for terahertz radiation
    Jewell, S. A.
    Hendry, E.
    Isaac, T. H.
    Sambles, J. R.
    NEW JOURNAL OF PHYSICS, 2008, 10
  • [25] Thermal model of a switching Fabry-Perot etalon
    Bovard, Bertrand
    Macleod, H.Angus
    Proceedings of SPIE - The International Society for Optical Engineering, 1988, 821 : 187 - 197
  • [26] THE FABRY-PEROT ETALON AS AN RF FREQUENCY CHANNELIZER
    ALEXANDER, EM
    GAMMON, RW
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1984, 464 : 45 - 52
  • [27] A DEVICE FOR ALIGNING A LARGE FABRY-PEROT ETALON
    ROGERS, GL
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1969, 2 (11): : 1006 - &
  • [28] Chromatic drift of the Espresso Fabry-Perot etalon
    Schmidt, Tobias M.
    Chazelas, Bruno
    Lovis, Christophe
    Dumusque, Xavier
    Bouchy, Francois
    Pepe, Francesco
    Figueira, Pedro
    Sosnowska, Danuta
    ASTRONOMY & ASTROPHYSICS, 2022, 664
  • [29] GRAVITY-ADJUSTED FABRY-PEROT ETALON
    BURNETT, CR
    LAMMER, WE
    APPLIED OPTICS, 1969, 8 (11): : 2345 - &
  • [30] OPTICALLY-ACTIVE FABRY-PEROT ETALON
    LALOV, IJ
    MITEVA, AI
    JOURNAL OF MODERN OPTICS, 1991, 38 (02) : 395 - 411