Practical correlations for the thermal resistance of vertical enclosed airspaces for building applications

被引:15
|
作者
Saber, Hamed H. [1 ]
机构
[1] Natl Res Council Canada, Construct Portfolio, Ottawa, ON K1A 0R6, Canada
关键词
Reflective insulation; Low emissivity material; Thermal modeling; R-value correlation; Airflow in enclosed airspace; Heat transfer by convection; conduction and radiation; PERFORMANCE;
D O I
10.1016/j.buildenv.2012.09.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Many parts of the building envelope contain enclosed airspaces. The thermal resistance (R-value) of an enclosed airspace depends on the emissivity of all surfaces that bound the airspace, the size and orientation of the airspace, the direction of heat transfer through the airspace, and the respective temperatures of all surfaces that define the airspace. The 2009 ASHRAE Handbook of Fundamentals (Chapter 26) provides a table that contains the R-values for an enclosed airspace. The ASHRAE table is extensively used by modelers, architects and building designers in the design of building enclosures. This table provides R-values for enclosed airspaces for different values of the thickness of the airspace, effective emittance, mean airspace temperature, and temperature differences across the airspace. The effect of the airspace aspect ratio (height/thickness of airspace) on the R-value is not included in the ASHRAE table. However, in a recent study on the R-value of reflective insulations using a numerical simulation model, it was shown that the aspect ratio of the airspace can affect the R-value of the enclosed airspace. The numerical simulation model used in this study had been benchmarked against experimental data obtained using two standard test methods: ASTM C-518 and ASTM C-1363. In this paper, a numerical simulation study was conducted, that was based on previous work focused on enclosed airspaces, to investigate the effect of the aspect ratio on the R-value of vertical enclosed airspaces of different thicknesses and having a wide range of values for effective emittance, mean temperature, and temperature differences across the airspace. The R-values predicted from numerical simulation are compared with those provided in the ASHRAE table. Considerations were also given to investigating the potential increase in R-values of enclosed airspaces when a thin sheet is placed vertically in the middle of the airspace and whose surfaces have different values of emissivity. Finally, practical correlations are developed for determining the R-values of an enclosed airspace for future use by modelers, architects and building designers. The simplicity of these correlations suggests that these could be included in the ASHRAE Handbook of Fundamentals. Crown Copyright (c) 2012 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:379 / 396
页数:18
相关论文
共 50 条
  • [21] Obtaining the thermal resistance of air enclosed at the interface of multilayer fabrics by simulation
    Shen, Hua
    Tu, Lexi
    Yan, Xiaofei
    Sukigara, Sachiko
    TEXTILE RESEARCH JOURNAL, 2019, 89 (15) : 3178 - 3188
  • [22] Thermal Environment Monitoring and Model Development of an Enclosed Vertical-Type Composting Facility
    Seo, Hyo-Jae
    Lee, Dong-Hyun
    Seo, Il-Hwan
    APPLIED SCIENCES-BASEL, 2024, 14 (10):
  • [23] LINEAR THERMAL BRIDGES AT VERTICAL ELEMENTS OF BUILDING STRUCTURE
    Lupan, Lidia-Maria
    Moga, Ioan
    JOURNAL OF APPLIED ENGINEERING SCIENCES, 2012, 2 (01) : 59 - 70
  • [24] Thermal evaluation of vertical greenery systems for building walls
    Wong, Nyuk Hien
    Tan, Alex Yong Kwang
    Chen, Yu
    Sekar, Kannagi
    Tan, Puay Yok
    Chan, Derek
    Chiang, Kelly
    Wong, Ngian Chung
    BUILDING AND ENVIRONMENT, 2010, 45 (03) : 663 - 672
  • [25] Investigation of practical issues in building thermal parameter estimation
    Chen, TY
    Athienitis, AK
    BUILDING AND ENVIRONMENT, 2003, 38 (08) : 1027 - 1038
  • [26] PRACTICAL APPLICATIONS OF FIRE RESEARCH TO INNOVATION IN BUILDING DESIGN
    HAM, SJ
    FIRE AND MATERIALS, 1988, 13 : 213 - 220
  • [27] Convective heat transfer correlations for an enclosed horizontal compound parabolic cavity solar thermal collector
    Kothdiwala, A.F.
    Eames, P.C.
    Norton, B.
    International Journal of Solar Energy, 2000, 20 (03) : 161 - 175
  • [28] Experimental study on indoor thermal environment of industrial building spaces enclosed by fabric membranes
    Tian, Guoji
    Fan, Yuesheng
    Wang, Huan
    Zheng, Huifan
    Gao, Mingchen
    Liu, Jie
    Liu, Changzhou
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2020, 27 (04) : 451 - 461
  • [29] Thermal resistance of a window with an enclosed venetian blind: Guarded heater plate measurements
    Huang, Ned Y. T.
    Wright, John L.
    Collins, Michael R.
    ASHRAE TRANSACTIONS 2006, VOL 112, PT 2, 2006, 112 : 13 - +
  • [30] Thermal spreading resistance in multilayered contacts: Applications in thermal contact resistance
    Muzychka, YS
    Sridhar, MR
    Yovanovich, MM
    Antonetti, VW
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 1999, 13 (04) : 489 - 494