Laser profilometer using a Fabry-Perot etalon and an objective

被引:2
|
作者
Lin, Shyh-Tsong [1 ]
Yeh, Sheng-Lih [2 ]
Wang, Yi-Chun [3 ]
Chen, Meng-Zhu [1 ]
机构
[1] Natl Taipei Univ Technol, Dept Electroopt Engn, Taipei 10608, Taiwan
[2] Lunghwa Univ Sci & Technol, Dept Mech Engn, Lunghwa, Taiwan
[3] Wu Feng Agr & Ind Vocat High Sch, Dept Elect Tech, Taipei, Taiwan
关键词
Laser profilometer; Fabry-Perot etalon; Objective; OPTICAL COHERENCE TOMOGRAPHY; INTERFERENCE MICROSCOPES; NUMERICAL APERTURE; CALIBRATION; MIRAU;
D O I
10.1016/j.sna.2013.08.001
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper introduces an innovative laser profilometer using a Fabry-Perot etalon and an objective. Following the derivation of the measurement theory, an experimental setup constructed to realize the profilometer is demonstrated, and the experimental results from the uses of this setup are then presented. The experimental setup has a sensitivity, vertical resolution, and stability of 1.62/mu m, 2.2 nm, and 6.6 nm, respectively, and the experimental results agree not only the validity but also the feasibility of the proposed profilometer. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:47 / 51
页数:5
相关论文
共 50 条
  • [31] Volume hologram - Coupled Fabry-Perot etalon
    He, XD
    Liu, DH
    Zhou, J
    OPTIK, 2003, 114 (08): : 379 - 383
  • [32] Temperature insensitive design of Fabry-Perot etalon
    Shirasaki, M
    IEEE PHOTONICS TECHNOLOGY LETTERS, 1999, 11 (11) : 1431 - 1433
  • [33] ANALYTICAL DESCRIPTION OF AN IMPERFECT FABRY-PEROT ETALON
    PRIKRYL, I
    APPLIED OPTICS, 1984, 23 (04): : 621 - 627
  • [34] LOW-COST FABRY-PEROT ETALON
    HILTON, JW
    AMERICAN JOURNAL OF PHYSICS, 1968, 36 (01) : R9 - &
  • [35] Generation of CW terahertz radiation using two-colour laser with Fabry-Perot etalon
    Naftaly, M
    Stone, MR
    Malcoci, A
    Miles, RE
    Mayorga, IC
    ELECTRONICS LETTERS, 2005, 41 (03) : 128 - 129
  • [36] INTENSITY TRANSMITTED BY A FABRY-PEROT ETALON WITH ANOTHER INTERNAL FABRY-PEROT-INTERFEROMETER
    BERNABEU, E
    AMARE, JC
    ALVAREZ, JM
    MORENO, F
    APPLIED OPTICS, 1981, 20 (12): : 2117 - 2120
  • [37] High frequency ultrasound imaging using Fabry-Perot optical etalon
    Ashkenazi, S
    Witte, R
    O'Donnell, M
    Medical Imaging 2005: Ultrasonic Imaging and Signal Processing, 2005, 5750 : 289 - 297
  • [38] Fast calibration parameters of Fabry-Perot etalon by laser linear frequency sweep
    An, Panlong
    Zhao, Ruijuan
    Liu, Zhengguang
    Zhang, Xufeng
    Li, Yijun
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2015, 44 (11): : 3418 - 3422
  • [39] SELECTION OF ION-LASER FREQUENCY BY MEANS OF INCLINED FABRY-PEROT ETALON
    KOROLYOV, FA
    AFONNIKOV, NA
    GRIN, LE
    LEBEDEVA, VV
    ODINTSOV, AI
    OPTIKA I SPEKTROSKOPIYA, 1978, 44 (06): : 1143 - 1146
  • [40] High frequency ultrasound imaging using Fabry-Perot optical etalon
    Ashkenazi, S
    Witte, R
    O'Donnell, M
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2005, 2005, 5697 : 243 - 250