Ultrasound-Guided Hip Injections: A Comparative Study With Fluoroscopy-Guided Injections

被引:54
|
作者
Byrd, J. W. Thomas [1 ]
Potts, Elizabeth A. [1 ]
Allison, Rachel K. [1 ]
Jones, Kay S. [1 ]
机构
[1] Nashville Sports Med Fdn, Nashville, TN 37203 USA
关键词
ADULT HIP; ACCURACY;
D O I
10.1016/j.arthro.2013.09.083
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose was to assess ultrasound-guided injections through patient satisfaction in a comparative internally controlled study of fluoroscopic versus ultrasound technique and to quantitate the reliability of the ultrasound method. In addition, the reliability of the ultrasound method was quantitated. Methods: This study consisted of the first 50 consecutive patients to undergo ultrasound-guided intra-articular injection of the hip (by a nurse practitioner) and who had previously undergone fluoroscopy-guided intra-articular injections by our center's fellowship-trained musculoskeletal radiologists. The patients rated the ultrasound and fluoroscopic experiences on a scale from 1 to 10 for convenience and pain; in addition, they indicated their preference between the 2 techniques. Success of the injection was documented among a total of 206 consecutive patients who underwent ultrasound-guided injections during the period of the controlled study. Results: For convenience, ultrasound injection had a mean rating of 9.8 whereas fluoroscopic injection had a mean rating of 3.1. For pain, ultrasound had a mean rating of 3 and fluoroscopy had a mean rating of 5.6. These differences were statistically significant (P < .01) in favor of ultrasound. For preference, 49 of 50 patients in the control study (98%) stated that they would prefer the ultrasound injection, whereas 1 was uncertain. The injection was successful in 202 of the first 206 patients (98%) to undergo ultrasound injection, whereas 4 patients required a second pass for successful injection. Conclusions: In this study in-office ultrasound-guided injections of the hip were more convenient and less painful than fluoroscopy-guided hospital-based injections and were preferred by patients who have undergone both. Furthermore, the ultrasound-guided injections were performed by a recently trained physician extender in contrast to the fluoroscopic method, which was performed by experienced fellowship-trained musculoskeletal radiologists. The procedure is highly successful in the hands of a properly trained clinician. Level of Evidence: Level II, prospective comparative study.
引用
收藏
页码:42 / 46
页数:5
相关论文
共 50 条
  • [21] How to perform ultrasound-guided injections
    Bruyn, George A. W.
    Schmidt, Wolfgang A.
    BEST PRACTICE & RESEARCH IN CLINICAL RHEUMATOLOGY, 2009, 23 (02): : 269 - 279
  • [22] The Use of Ultrasound-Guided Injections for Tendinopathies
    Orchard J.W.
    Saw R.
    Masci L.
    Current Radiology Reports, 6 (10)
  • [23] Ultrasound-guided injections for plantar fasciitis
    Analay, Pelin
    Abdulsalam, Ahmad
    Kara, Murat
    Levent, Ozcakar
    TURKISH JOURNAL OF PHYSICAL MEDICINE AND REHABILITATION, 2024,
  • [24] Ultrasound-guided carpal tunnel injections
    Tumpaj, Tilen
    Tumpaj, Vesna Potocnik
    Albano, Domenico
    Snoj, Ziga
    RADIOLOGY AND ONCOLOGY, 2022, 56 (01) : 14 - 22
  • [25] Ultrasound-guided injections and aspirations of the extremities
    De Smet, AA
    SEMINARS IN ROENTGENOLOGY, 2004, 39 (01) : 145 - 154
  • [26] Ultrasound-Guided Sacroiliac Joint Injections
    De Luigi, Arthur Jason
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2020, 99 (06) : E79 - E80
  • [27] Ultrasound-guided injections in the lumbar spine
    Loizides, Alexander
    Peer, Siegfried
    Plaikner, Michaela
    Spiss, Verena
    Galiano, Klaus
    Obernauer, Jochen
    Gruber, Hannes
    MEDICAL ULTRASONOGRAPHY, 2011, 13 (01) : 54 - 58
  • [28] Efficacy of Ultrasound-Guided Corticosteroid Injections
    Jelsing E.J.
    Finnoff J.T.
    Current Physical Medicine and Rehabilitation Reports, 2016, 4 (2) : 132 - 137
  • [29] Effective Dose of CT- and Fluoroscopy-Guided Perineural/Epidural Injections of the Lumbar Spine: A Comparative Study
    Gebhard Schmid
    Alexander Schmitz
    Dieter Borchardt
    Klaus Ewen
    Thomas von Rothenburg
    Odo Koester
    Michael Jergas
    CardioVascular and Interventional Radiology, 2006, 29 : 84 - 91
  • [30] Effective dose of CT- and fluoroscopy-guided perineural/epidural injections of the lumbar spine: A comparative study
    Schmid, G
    Schmitz, A
    Borchardt, D
    Ewen, K
    von Rothenburg, T
    Koester, O
    Jergas, M
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 29 (01) : 84 - 91