Droplet temperature measurement based on 2-color laser-induced exciplex fluorescence

被引:25
|
作者
Zhang, Yuyin [1 ]
Zhang, Gaoming [1 ]
Xu, Min [1 ]
Wang, Jianxin [2 ]
机构
[1] Shanghai Jiao Tong Univ, Natl Engn Lab Automot Elect Control Technol, Sch Mech Engn, Shanghai 200240, Peoples R China
[2] Tsinghua Univ, State Key Lab Automot Safety & Energy, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
GLOBAL RAINBOW THERMOMETRY; LIQUID-PHASE; COMBUSTING DROPLETS; VAPORIZATION MODEL; FUEL SPRAYS; EVAPORATION; VAPOR; ENGINES; SYSTEMS; RATIO;
D O I
10.1007/s00348-013-1583-6
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Measurements of liquid phase temperature distributions in liquid-vapor co-existing conditions (such as in evaporating sprays) are important to understand the physics of droplet evaporation. The techniques based on laser-induced fluorescence are not suitable for evaporating case since both liquid and vapor phases emit fluorescence with the same wavelength. In this study, the fluorescence from liquid and vapor phases was separated by use of laser-induced exciplex fluorescence (LIEF) technique. Two fluorescence bands from the liquid phase fluorescence spectra were detected simultaneously, and their intensity ratio was correlated to the liquid phase temperature. For the LIEF imaging system, FB-DEMA-n-hexane was selected as it was a typical LIEF system for the vapor concentration diagnostic, and thus easily to be extended to a simultaneous diagnostic on the vapor concentration and the droplet temperature. The fluorescence spectra were obtained in the temperature range from 303 to 423 K. The effects of liquid temperature, liquid pressure, dopant concentration and laser energy on the temperature measurement were investigated. The results show a good linear relationship between the fluorescence ratio and the temperature function. Increasing the dopant concentration can raise the signal-to-noise ratio but deteriorate temperature sensitivity. The optimal range of the dopant concentration was found between 0.1 % and 0.5 %. After calibration, the technique was applied to a monosized droplet stream, and the measurement results demonstrated excellent measurement accuracy with error below 1 % in the range of 303-423 K.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Microscale laser-induced fluorescence method for non-intrusive temperature measurement
    Chamarthy, Pramod
    Wereley, Steven T.
    Garimella, Suresh V.
    INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2007, VOL 11 PT A AND PT B: MICRO AND NANO SYSTEMS, 2008, : 827 - 834
  • [32] Temperature measurement and state determination of supercooled droplets using laser-induced fluorescence
    M. Stiti
    A. Labergue
    F. Lemoine
    S. Leclerc
    D. Stemmelen
    Experiments in Fluids, 2019, 60
  • [33] Temperature measurement and state determination of supercooled droplets using laser-induced fluorescence
    Stiti, M.
    Labergue, A.
    Lemoine, F.
    Leclerc, S.
    Stemmelen, D.
    EXPERIMENTS IN FLUIDS, 2019, 60 (04)
  • [34] SIMULTANEOUS MEASUREMENT OF DROPLET VELOCITY AND SIZE AND FLAME MANTLE TEMPERATURE BY PHASE DOPPLER ANEMOMETRY AND 2-COLOR PYROMETRY
    ISRAEL, F
    TAYLOR, AMKP
    WHITELAW, JH
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1995, 6 (06) : 727 - 741
  • [35] A laser-induced fluorescence measurement for aqueous fluid flows with improved temperature sensitivity
    Sutton, Jeffrey A.
    Fisher, Brian T.
    Fleming, James W.
    EXPERIMENTS IN FLUIDS, 2008, 45 (05) : 869 - 881
  • [36] Temperature measurements of binary droplets using three-color laser-induced fluorescence
    C. Maqua
    G. Castanet
    Fabrice Lemoine
    N. Doué
    G. Lavergne
    Experiments in Fluids, 2006, 40
  • [37] Temperature measurements of binary droplets using three-color laser-induced fluorescence
    Maqua, C
    Castanet, G
    Lemoine, F
    Doue, N
    EXPERIMENTS IN FLUIDS, 2006, 40 (05) : 786 - 797
  • [38] 2-COLOR PYROMETER MEASUREMENT OF THE TEMPERATURE OF INDIVIDUAL COMBUSTING PARTICLES
    JORGENSEN, FRA
    ZUIDERWYK, M
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1985, 18 (06): : 486 - 491
  • [39] Planar 2-color time-resolved laser-induced incandescence measurements of soot in a diffusion flame
    Tian, B.
    Zhang, C.
    Gao, Y.
    Hochgreb, S.
    AEROSOL SCIENCE AND TECHNOLOGY, 2017, 51 (12) : 1345 - 1353
  • [40] OBSERVATION OF HYPERFINE QUANTUM BEATS IN 2-COLOR LASER-INDUCED GRATING SPECTROSCOPY OF NITRIC-OXIDE
    MCCORMACK, EF
    PRATT, ST
    DEHMER, PM
    DEHMER, JL
    CHEMICAL PHYSICS LETTERS, 1994, 227 (06) : 656 - 662