EFFECTS OF DIFFERENT LATERAL FEMORAL WALL THICKNESSES IN INTERTROCHANTERIC HIP FRACTURE TREATED WITH DYNAMIC HIP SCREW

被引:2
|
作者
Wang, Cheng-Chi [1 ,2 ]
Lee, Cheng-Hung [1 ,3 ]
Chen, Kun-Hui [1 ,4 ]
Pan, Chien-Chou [1 ]
Su, Kuo-Chih [4 ,5 ]
机构
[1] Taichung Vet Gen Hosp, Dept Orthoped, Taichung, Taiwan
[2] Nantou Hosp, Minist Hlth & Welf, Dept Orthoped, Nantou, Taiwan
[3] Hung Kuang Univ, Dept Food Sci & Technol, Taichung, Taiwan
[4] Hung Kuang Univ, Dept Biomed Engn, Taichung, Taiwan
[5] Taichung Vet Gen Hosp, Dept Med Res, Taichung, Taiwan
关键词
Biomechanics; finite element analysis; dynamic hip screw; intertrochanteric hip fracture; lateral femoral wall thickness; FINITE-ELEMENT; PREDICTOR;
D O I
10.1142/S0219519419400220
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Dynamic hip screw (DHS) is commonly used for stable-type intertrochanteric hip fractures. The importance of lateral femoral wall has been mentioned while treating intertrochanteric hip fractures with DHS. The aim of this study was mainly to investigate the biomechanical effect of different thickness of lateral femoral wall using finite element analysis (FEA). This study constructed FEA simulation models for five different lateral femoral wall thicknesses, and demonstrated the stress distribution on the femoral bone, the cortical screws, the cancellous bone around the lag screw, and the lag screw. The main results showed that when the DHS is implanted, less stress will be distributed at the implantation site on the femur due to the stress-shielding effect. The stress on the cortical screws will be greater at the junction of the cortical screws and the cortical bone. Intertrochanteric hip fractures with a thinner lateral wall thickness may cause higher stress on the femur after DHS is implanted.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Integrity of the lateral femoral wall in intertrochanteric hip fractures: An important predictor of a reoperation
    Gotfried, Yechiel
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (11): : 2552 - 2553
  • [22] Intramedullary hip screw versus sliding hip screw for unstable intertrochanteric femoral fractures in the elderly
    Harrington, P
    Nihal, A
    Singhania, AK
    Howell, FR
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2002, 33 (01): : 23 - 28
  • [23] Unstable Intertrochanteric Fracture Fixation - Is Proximal Femoral Locked Compression Plate Better Than Dynamic Hip Screw
    Asif, Naiyer
    Ahmad, Sohail
    Qureshi, Owais Ahmad
    Jilani, Latif Zafar
    Hamesh, Tajdar
    Jameel, Tariq
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2016, 10 (01) : RC9 - RC13
  • [24] INTERTROCHANTERIC FRACTURES OF THE HIP TREATED WITH THE HIP COMPRESSION SCREW - ANALYSIS OF PROBLEMS
    DOHERTY, JH
    LYDEN, JP
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1979, (141) : 184 - 187
  • [25] Proximal femoral locking plate versus dynamic hip screw for unstable intertrochanteric femoral fractures
    Upadhyay, Sachin
    Raza, H. K. T.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2014, 22 (01) : 130 - 131
  • [26] TREATMENT OF UNSTABLE INTERTROCHANTERIC FRACTURE OF FEMUR WITH DYNAMIC HIP SCREW VERSUS PROXIMAL FEMORAL NAIL: A COMPARATIVE STUDY
    Chander, S. G.
    Kanagasarathy, K.
    Chander, Vijaysharathy
    Reddy, Narayana M.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (59): : 10284 - 10293
  • [27] Proximal femoral locking plate versus dynamic hip screw for unstable intertrochanteric femoral fractures
    Dhamangaonkar, Anoop C.
    Joshi, Deepak
    Goregaonkar, Arvind B.
    Tawari, Akhil A.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2013, 21 (03) : 317 - 322
  • [28] Dynamic Hip Screw Augmented by Trochanteric Stabilizing Plate versus Proximal Femoral Nail in Fixing Unstable intertrochanteric Femoral Fracture
    Kelany, Ahmed Ayman
    Saied, Mahmoud Mabrouk
    Wahd, Yaser El Sayed Hassan
    Elfeshawy, Mohamed Ramadan
    JOURNAL OF POPULATION THERAPEUTICS AND CLINICAL PHARMACOLOGY, 2023, 30 (04): : E34 - E44
  • [29] Dynamic hip screw blade fixation for intertrochanteric hip fractures Reply
    Fang, Christian
    Leung, Frankie
    JOURNAL OF ORTHOPAEDIC SURGERY, 2013, 21 (01) : 133 - 133
  • [30] Comparison of Intertrochanteric Fracture Fixation with Dynamic Hip Screw and Bipolar Hemiarthroplasty Techniques
    Emami, Mohamad
    Manafi, Alireza
    Hashemi, Behrooz
    Nemati, Ali
    Safari, Saeed
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2013, 1 (01): : 14 - 17