Chinese SPECT semi-quantitative analysis of striatum

被引:0
|
作者
Wang Yuankai [1 ]
Liu Xingdang [1 ]
Zuo Chuantao [2 ]
Liu Congjin [1 ]
Liu Miao [1 ]
Zhang Guangming [1 ]
Chen Zhengping
Tang Jie
机构
[1] Fudan Univ, Huashan Hosp, Dept Nucl Med, Shanghai 200040, Peoples R China
[2] Fudan Univ, Huashan Hosp, PET Ctr, Shanghai 200040, Peoples R China
关键词
Tomography Emission-Computed Single-Photon; Image enhancement; Tc-99m-trodat-1; Striatum; DOPAMINE TRANSPORTER LIGAND; PET; RELEASE; F-18-FECNT; DECLINE;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
To study and analyze reconstruction parameters in Tc-99m-Trodat-1 SPECT (Tomography Emission-Computed Single-Photon) brain semi-quantitative analysis, and the outlined methods of ROIs (regions of interests). The Tc-99m-trodat-1 SPECT brain imaging was processed, and the ROIs were outlined four times from December 2009 to July 2011. The results for each method were analyzed and compared to improve our experience. There was no statistically significance between the outlined number of pixel in both sides of the cerebellum and the ratio of the radioactive counts. From LEHR and FAN beam collimator, the average ratio became better with increasing the outlining method, especially the fourth time. It could be estimated that striatum mean volume (+/- SD) was (39.51 +/- 9.54 ml, in the range of 19.97-51.98 mL) and mean weight (+/- SD) was (44.09 +/- 10.64 g in the range of 22.28-58.01 g). The details of image processing and data analysis should not be ignored to outline appropriate methods, and withstand the repetitive inspection. The total striatum was outlined and its volume and weight was analyzed.
引用
收藏
页码:355 / 360
页数:6
相关论文
共 50 条
  • [41] Visual and semi-quantitative assessment of brain tumors using Tl-201-SPECT
    Nose, Ayumi
    Otsuka, Hideki
    Nose, Hayato
    Otomi, Yoichi
    Terazawa, Kaori
    Harada, Masafumi
    JOURNAL OF MEDICAL INVESTIGATION, 2013, 60 (1-2): : 121 - 126
  • [42] Standardless semi-quantitative analysis with WDS-EPMA
    Fournier, C
    Merlet, C
    Dugne, O
    Fialin, M
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (03) : 381 - 386
  • [43] Development of reference values for DaTSCAN semi-quantitative analysis
    Neves, A.
    Ribeiro, B.
    Correia, M.
    Lameiras, V.
    Pereira, E.
    Oliveira, L.
    Carolino, E.
    Vieira, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S891 - S892
  • [44] Proportional scaling for semi-quantitative analysis of DaTSCAN uptake
    Apostolova, Ivayla
    Kupitz, Dennis
    Lange, Catharina
    Brenner, Winfried
    Amthauer, Holger
    Buchert, Ralph
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [45] Interobserver variability in the semi-quantitative assessment of 201Tl SPECT in cerebral gliomas
    Tony, B
    Vos, MJ
    Berkhof, J
    Postma, TJ
    van Lingen, A
    Heimans, JJ
    Hoekstra, OS
    NUCLEAR MEDICINE COMMUNICATIONS, 2005, 26 (01) : 45 - 48
  • [46] Usefulness of semi-quantitative analysis in cardiac amyloidosis.
    Venero Chaparro, J.
    Gallego Marquez, M.
    Sanchez Torrente, M.
    Gari Martinez, F.
    Guirado Llorente, D.
    Martinez-Valle Torres, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S618 - S618
  • [47] Appropriate utilization of semi-quantitative analysis in salivary scintigraphy
    Booker, J
    Howarth, D
    Taylor, L
    Voutnis, D
    Sutherland, D
    NUCLEAR MEDICINE COMMUNICATIONS, 2004, 25 (12) : 1203 - 1210
  • [48] Semi-Quantitative Group Testing
    Emad, Amin
    Milenkovic, Olgica
    2012 IEEE INTERNATIONAL SYMPOSIUM ON INFORMATION THEORY PROCEEDINGS (ISIT), 2012,
  • [49] Survey of semi-quantitative simulation
    Unit 302, Xi'an Institute of Hi-Tech, Xi'an 710025, China
    Xitong Fangzhen Xuebao, 2006, 9 (2375-2380):
  • [50] SEMI-QUANTITATIVE GAS CHROMATOGRAPHY
    EASTMAN, RH
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1957, 79 (15) : 4243 - 4243