Hemodynamic Comparison of Sutureless and Rapid-Deployment Valves with Conventional Bioprostheses

被引:9
|
作者
Gotzmann, Max [1 ]
Wilbring, Manuel [2 ]
Charitos, Efstratios [1 ]
Treede, Hendrik [1 ]
Silaschi, Miriam [1 ]
机构
[1] Midgerman Heart Ctr, Dept Cardiac Surg, Ernst Grube Str 40, D-06120 Halle, Saale, Germany
[2] Univ Heart Ctr Dresden, Dept Cardiac Surg, Dresden, Germany
来源
THORACIC AND CARDIOVASCULAR SURGEON | 2020年 / 68卷 / 07期
关键词
aortic valve/root; heart valve surgery; cardiac; REPLACEMENT; PERFORMANCE; SOCIETY;
D O I
10.1055/s-0039-1683426
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Sutureless and rapid-deployment bioprostheses (RPDs) are advantageous due to shorter aortic cross-clamp times (ACCs); however, few studies have investigated hemodynamic outcomes in comparison to conventional bioprostheses (CBs). Methods All patients receiving the Perceval (LivaNova, London, United Kingdom) and Intuity (Edwards Lifesciences, Irvine, California, United States) valves from February 2016 to December 2017 were included (n = 61). For controls, patients who underwent aortic valve replacement using CB from 2015 to 2018 (n = 743) were propensity-matched (n = 108). Primary end points were mean gradient at discharge, true internal diameter (ID) after implantation, and paravalvular leakage. Secondary end points were ACCs, cardiopulmonary bypass times (CPBTs), mortality, and pacemaker implantation. Results Age was 73.2 years (standard deviation [SD]: 7.6) in the RPD group and 72.9 years (SD: 7.3) in the CB group (p = 0.827). Median logistic EuroSCORE II was 3.4% (Q1: 2; IQ3: 5.3) and 3% (Q1: 1.9; IQ3: 5.6; p = 0.599). While ACCs and CPBT were shorter in RPDs (97 [SD: 31.4] vs. 125.4 minutes [SD: 62.1], p = 0.003; and 76.1 [SD: 25.7] vs. 89.7 minutes [SD: 34.3], p = 0.022), procedural times were similar (p = 0.257). True ID was 21.97 mm (SD: 1.79) in RPDs and 20.15 mm (SD: 1.70) in CB (p < 0.001). RPDs and CB resulted in comparable mean gradients (12.8 mm Hg [SD: 6.4] vs. 13.8 mm Hg [SD: 5.6]; p = 0.387) and rate of paravalvular regurgitation. There were no differences in the rates of pacemaker implantation and mortality. In a subanalysis of RPDs, mean gradient was 15.48 mm Hg (SD: 7.51) in Perceval (n = 21) and 10.79 mm Hg (SD: 4.78) in Intuity (n = 33; p = 0.010). Conclusions RPDs provided comparable hemodynamic performance, although implanted valves were larger in true ID. Whether this provides superior hemodynamic performance during exercise and longer durability needs further investigation. Among RPDs, the Intuity valve provided lower mean gradients at rest than Perceval valve.
引用
收藏
页码:584 / 594
页数:11
相关论文
共 50 条
  • [21] Combined valve surgery with sutureless and rapid-deployment aortic valve replacement: when and why
    Nguyen, Stephanie N.
    Cohn, Benjamin M.
    Nguyen, Tom C.
    ANNALS OF CARDIOTHORACIC SURGERY, 2020, 9 (05) : 408 - 410
  • [22] Current Clinical Evidence on Rapid Deployment Aortic Valve Replacement Sutureless Aortic Bioprostheses
    Barnhart, Glenn R.
    Shrestha, Malakh Lal
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2016, 11 (01) : 7 - 14
  • [23] The Call to Perfection: A High Bar for Sutureless and Rapid Deployment Aortic Valves
    Shi, William Y.
    Kaneko, Tsuyoshi
    ANNALS OF THORACIC SURGERY, 2022, 114 (03): : 765 - 766
  • [24] Pacemaker after Sutureless and Rapid-Deployment Prostheses: A Progress Report from the SURD-IR
    Pollari, Francesco
    Berretta, Paolo
    Albertini, Alberto
    Carrel, Thierry
    Teoh, Kevin
    Meuris, Bart
    Villa, Emmanuel
    Kappert, Utz
    Andreas, Martin
    Solinas, Marco
    Misfeld, Martin
    Savini, Carlo
    Fiore, Antonio
    Shrestha, Malakh
    Santarpino, Giuseppe
    Martinelli, Gian Luca
    Mignosa, Carmelo
    Glauber, Mattia
    Yan, Tristan
    Fischlein, Theodor
    Di Eusanio, Marco
    THORACIC AND CARDIOVASCULAR SURGEON, 2023, 71 (07): : 557 - 565
  • [25] Minimally invasive aortic valve replacement with sutureless and rapid deployment valves: a report from an international registry (Sutureless and Rapid Deployment International Registry)
    Berretta, Paolo
    Andreas, Martin
    Carrel, Thierry P.
    Solinas, Marco
    Teoh, Kevin
    Fischlein, Theodor
    Santarpino, Giuseppe
    Folliguet, Thierry
    Villa, Emmanuel
    Meuris, Bart
    Mignosa, Carmelo
    Martinelli, Gianluca
    Misfeld, Martin
    Glauber, Mattia
    Kappert, Utz
    Savini, Carlo
    Shrestha, Malak
    Phan, Kevin
    Albertini, Alberto
    Yan, Tristan
    Di Eusanio, Marco
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 56 (04) : 793 - 799
  • [26] Minimally invasive access type related to outcomes of sutureless and rapid deployment valves
    Andreas, Martin
    Berretta, Paolo
    Solinas, Marco
    Santarpino, Giuseppe
    Kappert, Utz
    Fiore, Antonio
    Glauber, Mattia
    Misfeld, Martin
    Savini, Carlo
    Mikus, Elisa
    Villa, Emmanuel
    Phan, Kevin
    Fischlein, Theodor
    Meuris, Bart
    Martinelli, Gianluca
    Teoh, Kevin
    Mignosa, Carmelo
    Shrestha, Malakh
    Carrel, Thierry P.
    Yan, Tristan
    Laufer, Guenther
    Di Eusanio, Marco
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2020, 58 (05) : 1063 - 1071
  • [27] The hemodynamic performance of balloon-expandable aortic bioprostheses in the elderly: a comparison between rapid deployment and transcatheter implantation
    Iacovelli, Fortunato
    Desario, Paolo
    Cafaro, Alessandro
    Pignatelli, Antonio
    Alemanni, Rossella
    Montesanti, Rosamaria
    Santo Bortone, Alessandro
    De Cillis, Emanuela
    De Palo, Micaela
    Bardi, Luca
    Martinelli, Gian Luca
    Tesorio, Tullio
    Cassese, Mauro
    Contegiacomo, Gaetano
    HELLENIC JOURNAL OF CARDIOLOGY, 2022, 68 : 9 - 16
  • [28] Rapid-Deployment Versus Conventional Bio-Prosthetic Aortic Valve Replacement
    Smith, Andrew L.
    Shi, William Y.
    Rosalion, Alexander
    Yii, Michael
    O'Keefe, Michael
    Newcomb, Andrew E.
    Davis, Philip
    HEART LUNG AND CIRCULATION, 2017, 26 (02): : 187 - 193
  • [29] Rapid deployment valves versus conventional tissue valves for aortic valve replacement
    White, Abigail
    Bozso, Sabin J.
    Lakey, Olivia
    Hong, Yongzhe
    Wang, Shaohua
    Nagendran, Jeevan
    Moon, Michael C.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2022, 163 (06): : 2036 - 2042
  • [30] The use of sutureless and rapid-deployment aortic valve prosthesis in patients with bicuspid aortic valve: A focused review
    King, Morgan
    Stambulic, Thomas
    Payne, Darrin
    Luis Fernandez, Angel
    El-Diasty, Mohammad
    JOURNAL OF CARDIAC SURGERY, 2022, 37 (10) : 3355 - 3362