SEISMIC EVALUATION OF MASONRY MONUMENTS THROUGH THE UTILIZATION OF IN SITU MEASUREMENTS CASE STUDY ON A BYZANTINE BASILICA

被引:1
|
作者
Salonikios, Thomas N. [1 ]
Morfidis, Kostantinos E. [1 ]
机构
[1] Inst Engn Seismol & Earthquake Engn EPPO ITSAK, POB 53 Finikas, GR-55102 Thessaloniki, Greece
来源
关键词
Masonry Monuments; Seismic Loads; Equivalent damping; Behaviour Factor; Earthquakes; Nonlinear response; In-situ Measurements; Post-Event Method; WALLS; EARTHQUAKE; BUILDINGS; DAMAGE;
D O I
10.5281/zenodo.1069529
中图分类号
K85 [文物考古];
学科分类号
0601 ;
摘要
This study develops an approach to examine parameters that are used for the estimation of seismic loads for historic buildings. A literature review is presented, and data from the literature and laboratory tests are used to assess the provisions that should be satisfied after the restoration of such buildings. In the analysis, frames with nonlinear properties that model stone masonry plain frames are used to estimate the equivalent seismic acceleration that these frames can resist. To investigate the response of masonry monuments to strong earthquakes, the observed response of many temples is considered during seven earthquakes in Greece, and the response spectra are defined for equivalent damping levels of 5%, 10%, and 20%. The aforementioned approaches are used to examine the possibility of further reducing the considered seismic loads for the evaluation of these structures. Alternative methods for the justified reduction of the seismic force by increasing the behavior factor are proposed. Finally a case study is presented on the initial contsruction stage of a byzantine basilica. In this case, the observed failure of the main roof of the temple and the limitation of damages to the rest of the structure thanks to the use of the findings of the present research is justified.
引用
收藏
页码:93 / 112
页数:20
相关论文
共 50 条
  • [31] Evaluation of timber floor in-plane retrofitting interventions on the seismic response of masonry structures by DEM analysis: a case study
    Alessandra Gubana
    Massimo Melotto
    Bulletin of Earthquake Engineering, 2021, 19 : 6003 - 6026
  • [32] Evaluation of timber floor in-plane retrofitting interventions on the seismic response of masonry structures by DEM analysis: a case study
    Gubana, Alessandra
    Melotto, Massimo
    BULLETIN OF EARTHQUAKE ENGINEERING, 2021, 19 (14) : 6003 - 6026
  • [33] Evaluations on the Seismic Vulnerability of Masonry Churches: a case study in Amantea (Cosenza - Italy)
    Olivito, Renato S.
    Porzio, Saverio
    Scuro, Carmelo
    Codispoti, Rosamaria
    INTERNATIONAL CONFERENCE OF COMPUTATIONAL METHODS IN SCIENCES AND ENGINEERING 2018 (ICCMSE-2018), 2018, 2040
  • [34] Critical issues in the assesment of seismic vulnerability of historical masonry buildings: A study case
    Calderoni, B.
    Cordasco, E. A.
    Pacella, G.
    Onotri, V
    BRICK AND BLOCK MASONRY: TRENDS, INNOVATIONS AND CHALLENGES, 2016, : 611 - 621
  • [35] Rapid evaluation of in-plane seismic capacity of masonry arch bridges through limit analysis
    Breccolotti, Marco
    Severini, Laura
    Cavalagli, Nicola
    Bonfigli, Federico M.
    Gusella, Vittorio
    EARTHQUAKES AND STRUCTURES, 2018, 15 (05) : 541 - 553
  • [36] Satellite radar interferometry and in-situ measurements for static monitoring of historical monuments: The case of Gubbio, Italy
    Cavalagli, N.
    Kita, A.
    Falco, S.
    Trillo, F.
    Costantini, M.
    Ubertini, F.
    REMOTE SENSING OF ENVIRONMENT, 2019, 235
  • [37] A numerical study on seismic risk assessment of historic masonry towers: a case study in San Gimignano
    Gianni Bartoli
    Michele Betti
    Andrea Vignoli
    Bulletin of Earthquake Engineering, 2016, 14 : 1475 - 1518
  • [38] A numerical study on seismic risk assessment of historic masonry towers: a case study in San Gimignano
    Bartoli, Gianni
    Betti, Michele
    Vignoli, Andrea
    BULLETIN OF EARTHQUAKE ENGINEERING, 2016, 14 (06) : 1475 - 1518
  • [39] Seismic Retrofit of Existing Masonry Buildings through Inter-story Isolation System: A Case Study and General Design Criteria
    Faiella, Diana
    Calderoni, Bruno
    Mele, Elena
    JOURNAL OF EARTHQUAKE ENGINEERING, 2022, 26 (04) : 2051 - 2087
  • [40] Methodologies for the evaluation of seismic vulnerability of complex masonry buildings: case histories in the historic centre of Sulmona
    Binda, L.
    Anzani, A.
    Cardani, G.
    STRUCTURAL STUDIES, REPAIRS AND MAINTENANCE OF HERITAGE ARCHITECTURE XI, 2009, 109 : 395 - 405