SEISMIC EVALUATION OF MASONRY MONUMENTS THROUGH THE UTILIZATION OF IN SITU MEASUREMENTS CASE STUDY ON A BYZANTINE BASILICA

被引:1
|
作者
Salonikios, Thomas N. [1 ]
Morfidis, Kostantinos E. [1 ]
机构
[1] Inst Engn Seismol & Earthquake Engn EPPO ITSAK, POB 53 Finikas, GR-55102 Thessaloniki, Greece
来源
关键词
Masonry Monuments; Seismic Loads; Equivalent damping; Behaviour Factor; Earthquakes; Nonlinear response; In-situ Measurements; Post-Event Method; WALLS; EARTHQUAKE; BUILDINGS; DAMAGE;
D O I
10.5281/zenodo.1069529
中图分类号
K85 [文物考古];
学科分类号
0601 ;
摘要
This study develops an approach to examine parameters that are used for the estimation of seismic loads for historic buildings. A literature review is presented, and data from the literature and laboratory tests are used to assess the provisions that should be satisfied after the restoration of such buildings. In the analysis, frames with nonlinear properties that model stone masonry plain frames are used to estimate the equivalent seismic acceleration that these frames can resist. To investigate the response of masonry monuments to strong earthquakes, the observed response of many temples is considered during seven earthquakes in Greece, and the response spectra are defined for equivalent damping levels of 5%, 10%, and 20%. The aforementioned approaches are used to examine the possibility of further reducing the considered seismic loads for the evaluation of these structures. Alternative methods for the justified reduction of the seismic force by increasing the behavior factor are proposed. Finally a case study is presented on the initial contsruction stage of a byzantine basilica. In this case, the observed failure of the main roof of the temple and the limitation of damages to the rest of the structure thanks to the use of the findings of the present research is justified.
引用
收藏
页码:93 / 112
页数:20
相关论文
共 50 条
  • [1] Seismic response evaluation of monuments based on ambient vibrations: the case studies of a Byzantine basilica and an Ottoman bath in Thessaloniki (Greece)
    Salonikios, Thomas
    Theodoulidis, Nikos
    Zacharopoulou, Georgia
    JOURNAL OF SEISMOLOGY, 2020, 24 (04) : 777 - 802
  • [2] Seismic response evaluation of monuments based on ambient vibrations: the case studies of a Byzantine basilica and an Ottoman bath in Thessaloniki (Greece)
    Thomas Salonikios
    Nikos Theodoulidis
    Georgia Zacharopoulou
    Journal of Seismology, 2020, 24 : 777 - 802
  • [3] Seismic response evaluation of ten tuff masonry churches with basilica plan through advanced numerical simulations
    Valente, Marco
    Brandonisio, Giuseppe
    Milani, Gabriele
    De Luca, Antonello
    INTERNATIONAL JOURNAL OF MASONRY RESEARCH AND INNOVATION, 2020, 5 (01) : 1 - 46
  • [4] Seismic performance evaluation of slender masonry towers: a case study
    Cakir, Ferit
    Uckan, Eren
    Shen, Jay
    Seker, Senol
    Akbas, Bulent
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2016, 25 (04): : 193 - 212
  • [5] Efficiency investigation of structural interventions based on in situ ambient vibration measurements on Acheiropoietos Early Byzantine basilica, Thessaloniki, Greece
    Salonikios, Thomas
    Theodoulidis, Nikolaos
    Morfidis, Konstantinos
    Zacharopoulou, Georgia
    Raptis, Konstantinos
    JOURNAL OF CIVIL STRUCTURAL HEALTH MONITORING, 2018, 8 (01) : 135 - 149
  • [6] Efficiency investigation of structural interventions based on in situ ambient vibration measurements on Acheiropoietos Early Byzantine basilica, Thessaloniki, Greece
    Thomas Salonikios
    Nikolaos Theodoulidis
    Konstantinos Morfidis
    Georgia Zacharopoulou
    Konstantinos Raptis
    Journal of Civil Structural Health Monitoring, 2018, 8 : 135 - 149
  • [7] Evaluation of the Performance of Unreinforced Stone Masonry Greek "Basilica" Churches When Subjected to Seismic Forces and Foundation Settlement
    Manos, George C.
    Kotoulas, Lambros
    Kozikopoulos, Evangelos
    BUILDINGS, 2019, 9 (05)
  • [8] Seismic Vulnerability Reduction of Masonry Churches: A case study
    Milani, Gabriele
    Shehu, Rafael
    Valente, Marco
    X INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS (EURODYN 2017), 2017, 199 : 272 - 277
  • [9] Seismic Retrofitting of Historic Masonry Buildings - Case Study
    Santhakumar, A. R.
    Mathews, M. S.
    Thirumurugan, S.
    Uma, Rao
    7TH INTERNATIONAL CONFERENCE ON STRUCTURAL ANALYSIS OF HISTORIC CONSTRUCTIONS: STRENGTHENING AND RETROFITTING, PTS 1 AND 2, 2010, 133-134 : 991 - 996
  • [10] Seismic damage evaluation of historical masonry towers through numerical model
    Dunfeng Xu
    Qifang Xie
    Wenming Hao
    Bulletin of Earthquake Engineering, 2024, 22 : 2235 - 2266