Hierarchical and Adaptive Volume-growing Methods for the PET based Biologic Target Volume Delineation for Radiotherapy Treatment Planning

被引:0
|
作者
Liu, Guocai [1 ]
Zhu, Suyu [2 ]
Wang, Yaonan [1 ]
Zhang, Jiutang [2 ]
Hu, Bingqiang [2 ]
ZhihaoYu [1 ]
Wu, Haiyan [1 ]
Yang, Weili [1 ]
机构
[1] Hunan Univ, Coll Elect & Informat Engn, Changsha 410082, Hunan, Peoples R China
[2] Hunan Prov Canc Hosp, Dept Radiat Oncol, Changsha, Hunan, Peoples R China
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To more accurately and precisely delineate a biologic target volume (BTV) for PET-guided radiotherapy treatment planning, we proposed a novel tumor segmentation method by hierarchically utilizing an adaptive volume-growing algorithm (AVGA). First, a rough volume of interest (VOI) is manually cut by a radiation oncologist that encloses a tumor volume. The voxel having the highest standard uptake values (SUV) in the manual VOI is chosen as a seed of the first AVGA. One of all 6-neighboring voxels (N-6) of the current tumor volume (CTV) is successively appended to the CTV. The growing criterion of the AVAG is that the SUV of the appended voxel is higher than the mean SUV of the CTV multiplied by a threshold value, and its SUV subtracted from the mean SUV of the CTV is a minimum in the N-6. We have always observed a sharp volume growth at a certain threshold value T-1 between 0.3 and 0.7, in which case many voxels outside of the delineated tumor volume are appended to the CTV. So, the first AVGA is stopped just before the sharp volume growth and the second AVGA is launched to refine the BTV delineation. The resulting CTV by the first AVGA is chosen as a seed volume of the second AVGA, and the threshold varies from T-1 to 0.30 with an adding growing criterion which the SUV of the current appended voxel is not higher than one of the last appended voxel. The idea behind is high-noise characteristics, partial volume effects due to the low spatial resolution, the tumor extension with lower SUV, and the spillover effects of some PET images. Patient studies were tested and evaluated by an experienced radiation oncologist. The results demonstrated that the proposed method can more accurately and precisely delineate a BTV due to the second AVGA. This method can automatically process PET images with different sizes of tumor volume and different signal to background ratios (SBR). The resulting BTV is reproducible and also independent of the initial VOI
引用
收藏
页码:4293 / 4295
页数:3
相关论文
共 50 条
  • [31] Radiotherapy planning: PET/CT scanner performances in the definition of gross tumour volume and clinical target volume
    Brianzoni, E
    Rossi, G
    Ancidei, S
    Berbellini, A
    Capoccetti, F
    Cidda, C
    D'Avenia, P
    Fattori, S
    Montini, GC
    Valentini, G
    Proietti, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 (12) : 1392 - 1399
  • [32] Impact of the accuracy of automatic tumour functional volume delineation on radiotherapy treatment planning
    Le Maitre, Amandine
    Hatt, Mathieu
    Pradier, Olivier
    Cheze-le Rest, Catherine
    Visvikis, Dimitris
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (17): : 5381 - 5397
  • [33] Geometrical Analysis of Radiotherapy Target Volume Delineation: a Systematic Review of Reported Comparison Methods
    Hanna, G. G.
    Hounsell, A. R.
    O'Sullivan, J. M.
    CLINICAL ONCOLOGY, 2010, 22 (07) : 515 - 525
  • [34] Implementation of PET-CT images for target volume definition in radiotherapy planning
    Khan, S
    Reiner, S
    Dizendorf, E
    Baumert, B
    Davis, JB
    STRAHLENTHERAPIE UND ONKOLOGIE, 2002, 178 : 130 - 130
  • [35] Investigation of statistical methods to analyze target volume definition among experts in radiotherapy treatment planning
    Naqa, I. E. I.
    Michalski, J.
    Lawton, C.
    Apte, A.
    Bosch, W.
    Deasy, J.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S126 - S126
  • [36] Implementation of hybrid PET/MRI for target volume delineation in stereotactic body radiotherapy of liver tumors
    Duma, M. N.
    Specht, H. M.
    Andratschke, N.
    Schiller, K.
    Molls, M.
    Schwaiger, M.
    Essler, M.
    EUROPEAN JOURNAL OF CANCER, 2013, 49 : S254 - S254
  • [37] PET imaging for target volume delineation in rectal cancer radiotherapy: results of a phase II study
    Floreno, B.
    Rinaldi, C.
    Fiore, M.
    Trecca, P.
    Greco, C.
    Iurato, A.
    D'Angelillo, R. M.
    Trodella, L.
    Ramella, S.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S813 - S813
  • [38] Assessment of 18F PET signals for automatic target volume definition in radiotherapy treatment planning
    Davis, J. Bernard
    Reiner, Beatrice
    Huser, Marius
    Burger, Cyrill
    Szekely, Gabor
    Ciernik, I. Frank
    RADIOTHERAPY AND ONCOLOGY, 2006, 80 (01) : 43 - 50
  • [39] Target volume delineation for three-dimensional treatment planning for lung cancer
    Kimura, T
    Hirokawa, Y
    Kenjo, M
    Kaneyasu, Y
    Kashimoto, K
    Ito, K
    RADIOLOGY, 2001, 221 : 175 - 175
  • [40] 18F-FDG PET/CT in staging and delineation of tumoral volume in radiotherapy planning
    Manchon Adsuar, F.
    Lopez Prior, V.
    Diaz Exposito, R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S608 - S608