Optimization of ejector-expansion transcritical CO2 heat pump cycle

被引:144
|
作者
Sarkar, Jahar [1 ]
机构
[1] Banaras Hindu Univ, Dept Mech Engn, Inst Technol, Varanasi 221005, Uttar Pradesh, India
关键词
ejector-expansion CO2 cycle; modelling; entrainment ratio; pressure lift ratio; optimization; performance comparison;
D O I
10.1016/j.energy.2008.04.007
中图分类号
O414.1 [热力学];
学科分类号
摘要
Optimization studies along with optimum parameter correlations, using constant area mixing model are presented in this article for ejector-expansion transcritical CO2 heat pump cycle with both conventional and modified layouts. Both the energetic and exergetic comparisons between valve, turbine and ejector-expansions-based transcritical CO2 heat pump cycles are also studied for simultaneous cooling and heating applications. Performances for conventional layouts are presented by maximum COP, optimum discharge pressure and corresponding entrainment ratio and pressure lift ratio of ejector, whereas for modified layout by maximum COP, optimum discharge pressure and corresponding pressure lift ratio. The optimization for modified layout can be realized for certain entrainment ratio, evaporator and gas cooler exit temperature combinations. Considering the trade-off between the system energetic and exergetic performances, and cost associated with expansion devices, the ejector may be the promising alternative expansion device for transcritical CO2 heat pump cycle. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1399 / 1406
页数:8
相关论文
共 50 条
  • [31] Particular characteristics of transcritical CO2 refrigeration cycle with an ejector
    Deng, Jian-qiang
    Jiang, Pei-xue
    Lu, Tao
    Lu, Wei
    APPLIED THERMAL ENGINEERING, 2007, 27 (2-3) : 381 - 388
  • [32] Performance investigation of a two-phase transcritical CO2 ejector heat pump system
    Taleghani, S. Taslimi
    Sorin, M.
    Poncet, S.
    Nesreddine, H.
    ENERGY CONVERSION AND MANAGEMENT, 2019, 185 : 442 - 454
  • [33] On the coupled system performance of transcritical CO2 heat pump and rankine cycle
    Hongli Wang
    Jingrui Tian
    Xiujuan Hou
    Heat and Mass Transfer, 2013, 49 : 1733 - 1740
  • [34] On the coupled system performance of transcritical CO2 heat pump and rankine cycle
    Wang, Hongli
    Tian, Jingrui
    Hou, Xiujuan
    HEAT AND MASS TRANSFER, 2013, 49 (12) : 1733 - 1740
  • [35] Dynamic model of a transcritical CO2 ejector expansion refrigeration system
    Zheng, Lixing
    Deng, Jianqiang
    He, Yang
    Jiang, Peixue
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 60 : 247 - 260
  • [36] Optimization analysis of Organic Rankine Cycle powered by waste heat of a supermarket transcritical CO2 multi-ejector refrigeration cycle
    Tsimpoukis, Dimitrios
    Syngounas, Evangelos
    Bellos, Evangelos
    Koukou, Maria
    Tzivanidis, Christos
    Anagnostatos, Stavros
    Vrachopoulos, Michail Gr
    JOURNAL OF CLEANER PRODUCTION, 2023, 418
  • [37] Theoretical analysis and optimization of a hybrid CO2 transcritical mechanical compression - ejector cooling cycle
    Chen, Guangming
    Volovyk, Oleksii
    Zhu, Daibin
    Ierin, Volodymyr
    Shestopalov, Kostyantyn
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 74 : 86 - 94
  • [38] Cycle parameter optimization of vortex tube expansion transcritical CO2 system
    Sarkar, Jahar
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2009, 48 (09) : 1823 - 1828
  • [39] Thermodynamic investigation and optimization of novel ejector-expansion CO2/NH3 cascade refrigeration cycles (novel CO2/NH3 cycle)
    Dokandari, Damoon Aghazadeh
    Hagh, Alireza Setayesh
    Mahmoudi, S. M. S.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 46 : 26 - 36
  • [40] Bi-objective optimization of transcritical CO2 heat pump systems
    Okasha, Ahmed
    Mueller, Norbert
    Deb, Kalyanmoy
    ENERGY, 2022, 247