Radiographic feasibility study of cortical bone trajectory and traditional pedicle screw dual trajectories

被引:27
|
作者
Mullin, Jeffrey P. [1 ]
Perlmutter, Breanna [1 ]
Schmidt, Eric [1 ]
Benzel, Edward [1 ]
Steinmetz, Michael P. [1 ]
机构
[1] Cleveland Clin Fdn, Dept Neurol Surg, 9500 Euclid Ave,Mail Code S100, Cleveland, OH 44195 USA
关键词
pedicle instrumentation; cortical bone trajectory; lumbar fusion; INSERTIONAL TORQUE; FIXATION STRENGTH; PLACEMENT;
D O I
10.3171/2016.4.SPINE151483
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE In 2009, Santoni and colleagues described a novel technique of posterior instrumentation; the cortical bone trajectory (CBT) was described as a caudocephalad and medial-to-lateral trajectory. Reported indications for CBT fixation include patients with osteoporosis, single-level degenerative disease, or adjacent-segment disease (ASD). In cases of revision surgery, it is technically possible and beneficial to place a traditional pedicle screw and a CBT screw at the same spinal level and side. It remains unclear as to the feasibility of placing both a traditional and a CBT screw at all levels of the lumbar spine and with varying trajectories of the preexisting traditional pedicle screws. Therefore, the authors conducted a study to radiographically assess the feasibility of using CBT and traditional pedicle screws at the same level in a large patient population. METHODS Using a 3D Spine Navigation WorkStation, the authors assessed 47 lumbar spine CT scans. These images were obtained from 2 disparate groups of patients: those who had previously undergone traditional pedicle instrumentation (prior surgery group) and those who had not (no prior surgery group). The authors virtually placed traditional pedicle and CBT screws at each lumbar level bilaterally. It was then determined if the dual trajectories were feasible, as defined by the presence or absence of a collision of the screw trajectories based on 3D imaging. RESULTS Overall, the authors evaluated 47 patients and were able to successfully plan dual trajectories in 50% of the pedicles. The no prior surgery group, compared with the prior surgery group, had a significantly greater success rate for dual trajectories. This difference was most significant in the lower lumbar levels (L3-5) where the prior instrumented group had success rates lower than 40% compared with the no prior surgery group's success rate, which was greater than 70%. There was a significant difference between each lumbar level in the lower spine. CONCLUSIONS There is a significant difference in the feasibility of planning CBT screws in patients who have undergone prior pedicle instrumentation compared with placing CBT and traditional pedicle screws simultaneously, but dual trajectory pedicle screws are a feasible option for posterior lumbar spinal instrumentation, especially as a de novo option in osteoporotic patients or in patients with ASD who underwent previous pedicle instrumentation. Ultimately, the practical clinical utility and biomechanical effects on the spine and instrumentation construct would require additional study.
引用
收藏
页码:727 / 732
页数:6
相关论文
共 50 条
  • [31] Feasibility of anterior pedicle screw fixation in lumbosacral spine: a radiographic and cadaveric study
    Xu, Wei-Xing
    Xu, Bin
    Ding, Wei-Guo
    Sheng, Hong-Feng
    Lu, Di
    Hu, Tian-Hong
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (12)
  • [32] Predictors of accurate intrapedicular screw placement in single-level lumbar (L4-5) fusion: robot-assisted pedicle screw, traditional pedicle screw, and cortical bone trajectory screw insertion
    Zhang, Hua-Qing
    Wang, Can-Can
    Zhang, Ren-Jie
    Zhou, Lu-Ping
    Jia, Chong-Yu
    Ge, Peng
    Shen, Cai-Liang
    BMC SURGERY, 2022, 22 (01)
  • [33] Predictors of accurate intrapedicular screw placement in single-level lumbar (L4-5) fusion: robot-assisted pedicle screw, traditional pedicle screw, and cortical bone trajectory screw insertion
    Hua-Qing Zhang
    Can-Can Wang
    Ren-Jie Zhang
    Lu-Ping Zhou
    Chong-Yu Jia
    Peng Ge
    Cai-Liang Shen
    BMC Surgery, 22
  • [34] Cortical bone trajectory screw technique
    Goel, Atul
    JOURNAL OF NEUROSURGERY-SPINE, 2018, 29 (01) : 121 - 122
  • [35] Differences in bone mineral density of trajectory between lumbar cortical and traditional pedicle screws
    Zhang, Renjie
    Gao, Hai
    Li, Huimin
    Xing, Tao
    Jia, Chongyu
    Zhang, Jianxiang
    Dong, Fulong
    Shen, Cailiang
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14 (1)
  • [36] Differences in bone mineral density of trajectory between lumbar cortical and traditional pedicle screws
    Renjie Zhang
    Hai Gao
    Huimin Li
    Tao Xing
    Chongyu Jia
    Jianxiang Zhang
    Fulong Dong
    Cailiang Shen
    Journal of Orthopaedic Surgery and Research, 14
  • [37] Morphometric Measurement of Cortical Bone Trajectory for Lumbar Pedicle Screw Insertion Using Computed Tomography
    Matsukawa, Keitaro
    Yato, Yoshiyuki
    Nemoto, Osamu
    Imabayashi, Hideaki
    Asazuma, Takashi
    Nemoto, Koichi
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2013, 26 (06): : E248 - E253
  • [38] Minimally Invasive Lumbar Pedicle Screw Fixation Using Cortical Bone Trajectory: Functional Outcomes
    Chen, Yiren
    Deb, Sayantan
    Jabarkheel, Rashad
    Pham, Lan
    Patel, Mahesh
    Singh, Harminder
    CUREUS, 2018, 10 (10):
  • [39] Cortical Bone Trajectory Pedicle Screw Fixation in Surgical Treatment of Monosegmental Pyogenic Lumbar Spondylodiskitis
    Shin, Jae-Hyuk
    Kim, Sang-Il
    Jung, Jiyoung
    Rhyu, Kee-Won
    JOURNAL OF NEUROLOGICAL SURGERY PART A-CENTRAL EUROPEAN NEUROSURGERY, 2023, 84 (01) : 37 - 43
  • [40] Cortical bone trajectory for lumbar pedicle screws
    Santoni, B. G.
    Hynes, R. A.
    McGilvray, K. C.
    Rodriguez-Canessa, G.
    Lyons, A. S.
    Henson, M. A. W.
    Womack, W. J.
    Puttlitz, C. M.
    SPINE JOURNAL, 2009, 9 (05): : 366 - 373