A COMPARISON OF TWO ALGORITHMS FOR AUTOMATED STONE DETECTION IN CLINICAL B-MODE ULTRASOUND IMAGES OF THE ABDOMEN

被引:7
|
作者
Gupta, Abhinav [1 ]
Gosain, Bhuvan [1 ]
Kaushal, Sunanda [1 ]
机构
[1] Jaypee Inst Informat Technol, Dept Elect & Commun, Noida, India
关键词
ultrasound; abdominal ultrasound images; stone detection; speckle noise; speckle reducing anisotropic diffusion; log decompression; watershed transform; SEGMENTATION; SPECKLE;
D O I
10.1007/s10877-010-9254-0
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Ultrasound (US) imaging is an indispensible technique for detection of abdominal stones which are a serious health hazard. Segmentation of stones from abdominal ultrasound images presents a unique challenge because these images contain strong speckle noise and attenuated artifacts. In clinical situations where a large number of stones must be identified, traditional methods such as manual identification become tedious and lack reproducibility too. The necessity of obtaining high reproducibility and the need to increase efficiency motivates the development of automated and fast procedures that segment out stones of all sizes and shapes in medical images by applying image segmentation techniques. In this paper we present and compare two fully automatic and unsupervised methods for robust stone detection in B-mode ultrasound images of the abdomen. Our approaches are based on the marker controlled watershed segmentation, along with some pre-processing and post-processing procedures that eliminate the inherent problems associated with medical ultrasound images. The first algorithm (Algorithm I) utilizes the advantage of the Speckle reducing anisotropic diffusion (SRAD) technique, along with unsharp filtering and histogram equalization for removal of speckle noise, and the second algorithm (Algorithm II) is based on the log decompression model which too serves as a tool for minimization of speckle. Experimental results obtained from processing a set of 50 ultrasound images ensure the robustness of both the proposed algorithms. Comparative results of both the algorithms based on efficiency and relative error in stone area have been provided.
引用
收藏
页码:341 / 362
页数:22
相关论文
共 50 条
  • [31] STATISTICAL MODELING OF B-MODE CLINICAL KIDNEY IMAGES
    Datta, Privanka
    Gupta, Abhinav
    Agrawal, Rajeev
    2014 INTERNATIONAL CONFERENCE ON MEDICAL IMAGING, M-HEALTH & EMERGING COMMUNICATION SYSTEMS (MEDCOM), 2015, : 222 - 229
  • [32] Comparison Of A-mode And B-mode Ultrasound For Measurement Of Subcutaneous Fat
    Wagner, Dale R.
    Judd, Trenton
    Gordon, Joshua
    McPherson, Casey
    Robison, Adrianna
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2018, 50 (05): : 158 - 158
  • [33] ARTIFICIAL INTELLIGENCE-ASSISTED PROSTATE CANCER DETECTION ON B-MODE TRANSRECTAL ULTRASOUND IMAGES
    Bhattacharya, Indrani
    Vesal, Sulaiman
    Jahanandish, Hassan
    Choi, Moonhyung
    Zhou, Steve
    Kornberg, Zachary
    Sommer, Elijah Richard
    Fan, Richard E.
    Brooks, James D.
    Rusu, Mirabela
    Sonn, Geoffrey A.
    JOURNAL OF UROLOGY, 2024, 211 (05): : E511 - E511
  • [34] COMPARISON OF A-MODE AND B-MODE ULTRASOUND FOR MEASUREMENT OF SUBCUTANEOUS FAT
    Wagner, Dale R.
    Teramoto, Masaru
    Judd, Trenton
    Gordon, Joshua
    Mcpherson, Casey
    Robison, Adrianna
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (04): : 944 - 951
  • [35] Automatic Lumen Detection on Longitudinal Ultrasound B-Mode Images of the Carotid Using Phase Symmetry
    Rouco, Jose
    Azevedo, Elsa
    Campilho, Aurelio
    SENSORS, 2016, 16 (03):
  • [36] Automated bone contour detection in ultrasound B-mode images for minimally invasive registration in computer-assisted surgery -: an in vitro evaluation
    Kowal, Jens
    Amstutz, Christoph
    Langlotz, Frank
    Talib, Haydar
    Ballester, Miguel Gonzalez
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2007, 3 (04): : 341 - 348
  • [37] MULTISCALE EDGE DETECTION AND GRADIENT VECTOR FLOW SNAKES FOR AUTOMATED IDENTIFICATION OF THE CAROTID ARTERY WALL IN LONGITUDINAL B-MODE ULTRASOUND IMAGES
    Matsakou, A. I.
    Tsiaparas, N.
    Golemati, S.
    Nikita, K. S.
    2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 1599 - 1602
  • [38] AUTOMATED POSTERIOR WALL THICKNESS MEASUREMENT FROM B-MODE ULTRASOUND
    Annangi, Pavan
    Subramanian, Navneeth
    Govind, Satish
    Swamy, Gokul
    Young, Brian
    2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 77 - 80
  • [39] Blood flow generation in B-MODE ultrasound images of the carotid artery
    Hamou, AK
    El-Sakka, MR
    ICIP: 2004 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOLS 1- 5, 2004, : 2945 - 2948
  • [40] Fully Automated Analysis of Muscle Architecture from B-Mode Ultrasound Images with DL_Track_US
    Ritsche, Paul
    V. Franchi, Martino
    Faude, Oliver
    Finni, Taija
    Seynnes, Olivier
    Cronin, Neil J.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (02): : 258 - 267