Bioactive glass as bone-graft substitute for posterior spinal fusion in rabbit

被引:13
|
作者
Lindfors, NC
Tallroth, K
Aho, AJ
机构
[1] Turku Univ, Biomat Project Turku, Turku 20520, Finland
[2] Orton Res Inst, Invalid Fdn, Helsinki 00280, Finland
[3] Univ Turku, Cent Hosp, Dept Surg, FIN-20520 Turku, Finland
来源
关键词
bioactive glass; spinal fusion; biomaterial; autograft bone; bone substitute;
D O I
10.1002/jbm.10177
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Bioactive glass S53P4 and autogenous bone were studied as bone graft materials for spinal fusion in a rabbit model. Sixteen rabbits underwent surgery by a dorsal approach. A bioactive glass, a combination of bioactive glass and autogenous bone (70/30 vol%), and autogenous bone were implanted at two thoracolumbar vertebraes for 4 and 12 weeks. The volume, consolidation to vertebrae, and fusion of the graft material were evaluated with plain-film radiology, computed tomography (CT) and bone-mineral density measurements, and compared with histomorphometrical measurements. Radiological consolidation by CT of bone graft to underlying vertebrae at 12 weeks was observable in all groups. This was histologically confirmed as bone was growing from the vertebrae into the graft material. Radiologic fusion of vertebraes was, at 12 weeks, observable in all groups in 50-75% of the cases. The radiologic fusion seen at the CT scans could, however, not be confirmed by histology in any of the three groups. Significant differences for graft material and observation period with the use of bone-mineral density measurements (Hounsfield units) were also observable, with the highest measured values for the bioactive glass group and the lowest for the autogenous bone group. The results indicate that bioactive glass have potential as bone-graft material in spinal fusion. The reliability of radiologic evaluation methods in spinal surgery using bone substitutes is also questioned and discussed. (C) 2002 John Wiley Sons, Inc.
引用
收藏
页码:237 / 244
页数:8
相关论文
共 50 条
  • [1] Collagen/β-TCP composite as a bone-graft substitute for posterior spinal fusion in rabbit model: a comparison study
    Lu, Yajie
    Li, Minghui
    Long, Zuoyao
    Yang, Di
    Guo, Shuo
    Li, Jing
    Liu, Dong
    Gao, Peng
    Chen, Guojing
    Lu, Xiao
    Lu, Jianxi
    Wang, Zhen
    BIOMEDICAL MATERIALS, 2019, 14 (04)
  • [2] IN-VIVO EVALUATION OF DEMINERALIZED BONE-MATRIX AS A BONE-GRAFT SUBSTITUTE FOR POSTERIOR SPINAL-FUSION
    COOK, SD
    DALTON, JE
    PREWETT, AB
    WHITECLOUD, TS
    SPINE, 1995, 20 (08) : 877 - 886
  • [3] CONTROLLED RELEASE GLASS AS A POTENTIAL BONE-GRAFT SUBSTITUTE
    BURNIE, J
    DOHERTY, RJ
    GILCHRIST, T
    DUFF, SRI
    MALCOLM, AJ
    DRAKE, CF
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1983, 65 (03): : 364 - 365
  • [4] TRICALCIUM PHOSPHATE AND OSTEOGENIN - A BIOACTIVE ONLAY BONE-GRAFT SUBSTITUTE
    BREITBART, AS
    STAFFENBERG, DA
    THORNE, CHM
    GLAT, PM
    CUNNINGHAM, NS
    REDDI, AH
    RICCI, J
    STEINER, G
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1995, 96 (03) : 699 - 708
  • [5] Posterior migration of bone-graft particles to the spinal canal after lumbar fusion: A case report
    He, Haichao
    Xu, Jie
    ASIAN JOURNAL OF SURGERY, 2023, 46 (04) : 1842 - 1843
  • [6] Negative Effect of Rapidly Resorbing Properties of Bioactive Glass-Ceramics as Bone Graft Substitute in a Rabbit Lumbar Fusion Model
    Lee, Jae Hyup
    Ryu, Hyun-Seung
    Seo, Jun-Hyuk
    Lee, Do-Yoon
    Chang, Bong-Soon
    Lee, Choon-Ki
    CLINICS IN ORTHOPEDIC SURGERY, 2014, 6 (01) : 87 - 95
  • [7] THE USE OF CORAL AS A BONE-GRAFT SUBSTITUTE
    GUILLEMIN, G
    PATAT, JL
    FOURNIE, J
    CHETAIL, M
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1987, 21 (05): : 557 - 567
  • [8] Surgical treatment for spinal brucellosis with posterior intervertebral bone-graft fusion and pedicle screw internal fixation
    Li, Yan
    Li, Yadong
    Shen, Linming
    Liu, Yongming
    ASIAN JOURNAL OF SURGERY, 2025, 48 (02) : 1265 - 1266
  • [9] FIBRILLAR COLLAGEN-BIPHASIC CALCIUM-PHOSPHATE COMPOSITE AS A BONE-GRAFT SUBSTITUTE FOR SPINAL-FUSION
    ZERWEKH, JE
    KOUROSH, S
    SCHEINBERG, R
    KITANO, T
    EDWARDS, ML
    SHIN, D
    SELBY, DK
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1992, 10 (04) : 562 - 572
  • [10] ANTERIOR CERVICAL DISKECTOMY AND FUSION USING A POROUS HYDROXYAPATITE BONE-GRAFT SUBSTITUTE
    ZDEBLICK, TA
    COOKE, ME
    KUNZ, DN
    WILSON, D
    MCCABE, RP
    SPINE, 1994, 19 (20) : 2348 - 2357