A Measurement and Verification Method for Energy Savings of Power Line Transformation Project

被引:0
|
作者
Meng Junxia [1 ]
Jiang Limin [1 ]
Liu Fuchao [2 ]
Zheng Jingjing [2 ]
Li Qi [3 ]
机构
[1] China Elect Power Res Inst, Beijing, Peoples R China
[2] State Grid Gansu Elect Power Res Inst, Nanjing, Jiangsu, Peoples R China
[3] North China Elect Power Univ, Beijing, Peoples R China
关键词
power line transformation; energy saving; measurement and verification;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Power line transformation projects, such as increasing diameter of lines, decreasing length of lines and boosting voltage level, are very common in power grid corporations. Besides meeting transmission capacity needs, these projects generate loss energy savings. Based on International Performance Measurement and Verification Protocol of efficiency valuation organization, this paper discusses a measurement and verification method for energy savings that generates from power line transformation projects, and gives details on how to measure parameters and calculate energy savings. The proposed method considers changes of operation situation after transformation, then a method by means of modifying baseline to solve transmission capacity varying are given in order to verify energy savings more objectively. Finally, uncertainty of the method is simply analyzed, as well as some points which might improve performance of the method further are described.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Low-cost energy meter calibration method for measurement and verification
    Carstens, Herman
    Xia, Xiaohua
    Yadavalli, Sarma
    APPLIED ENERGY, 2017, 188 : 563 - 575
  • [32] Comparative study of measurement and verification (M&V) baseline models for quantifying energy savings in building renovations
    Cabrera, Adalberto Guerra
    Ntimos, Dimitris
    SUSTAINABILITY IN THE BUILT ENVIRONMENT FOR CLIMATE CHANGE MITIGATION (SBE19), 2020, 410
  • [33] FLUID FLOW MEASUREMENT AND ENERGY SAVINGS.
    Alston, Norman A.
    Combustion, 1980,
  • [34] Impedance Measurement Method of Low-voltage Power Supply Line Based on Karrenbauer Phase-mode Transformation
    Huang R.
    Yu M.
    Liu Y.
    Xia X.
    Zhou G.
    Liu M.
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2021, 48 (08): : 90 - 95
  • [35] Measurement and Verification of Distribution Voltage Optimization Results for the IEEE Power & Energy Society
    Wilson, Thomas L.
    IEEE PES GENERAL MEETING, 2010,
  • [36] Theoretical and Experimental Verification of CVR Energy Savings for Refrigeration Loads
    Behzadirafi, Shayan
    Malallah, Yaaqoub
    Qaseer, Layth
    de Leon, Francisco
    IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (04) : 2489 - 2499
  • [37] The verification based on RTDS of fault line selection method for distribute power system
    Jiang, Tiewei
    Yu, Haibo
    Xia, Lei
    2012 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2012,
  • [38] The remote measurement of power and energy release by neutrino method
    Klimov, Yu.V.
    Kopejkin, V.I.
    Mikaelyan, L.A.
    Ozerov, K.V.
    Sinev, V.V.
    Atomnaya Energiya, 1994, 76 (02): : 130 - 135
  • [39] Green power, energy conservation, and cost savings
    Kennedy, Robert A.
    Simpson, Walter
    Strategic Planning for Energy and the Environment, 1999, 19 (01): : 6 - 22
  • [40] ENERGY SAVINGS BY COMBINED HEAT AND POWER PRODUCTION
    SCHOLZ, F
    ATOMKERNENERGIE-KERNTECHNIK, 1982, 40 (03): : 171 - 177