Comparison of two Meglumine-Diatrizoate based bowel preparations for computed tomography colonography: Comparison of patient symptoms and bowel preparation quality

被引:2
|
作者
Wilson, S. [1 ]
Thompson, J. D. [2 ]
机构
[1] North West Anglia NHS Fdn Trust, Peterborough PE3 9GZ, England
[2] Univ Salford, Manchester M6 6PU, Lancs, England
关键词
Computed tomography colonography; Meglumine-Diatrizoate; Bowel preparation; Visual grading; CT-COLONOGRAPHY; DIAGNOSTIC PERFORMANCE; RADIOLOGISTS; ACCEPTANCE; SOFTWARE; IOHEXOL; POLYPS; CANCER;
D O I
10.1016/j.radi.2020.04.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: To investigate the impact of two Meglumine-Diatrizoate based bowel preparation regimes for computed tomography colonography (CTC) on the patient experience and image quality. Methods: 100 patients consumed Meglumine-Diatrizoate at 24 h and 12 h prior to the CTC examination. 50 patients followed regime 1 (50:50), 50 ml of Meglumine-Diatrizoate at both 24 and 12 h prior to the examination. 50 patients followed regime 2 (75:25), 75 ml of Meglumine-Diatrizoate at 24 h prior to the examination and 25 ml of Meglumine-Diatrizoate at 12 h prior to the examination. All patients completed a questionnaire to indicate the time of onset of adverse effects and when they were most severe. Five advanced practitioners assessed the image quality in a visual grading study. Visual grading characteristic (VGC) analysis was applied with regime 1 as the reference condition and regime 2 and test condition; test alpha was set at 0.05. Results: Image quality was assessed with successful bowel cleansing as the scoring criteria for the visual grading study. The bowel cleansing as provided by the two Meglumine-Diatrizoate regimes was revealed not to be statistically different, with the area under the VGC curve and 95% confidence intervals 0.487 (0.287, 0.701), p = 0.887. Patients taking the 75:25 bowel preparation experienced a shorter median time to the onset of adverse effects. Conclusion: There was no observed difference in Image quality criteria score for the two Meglumine-Diatrizoate based bowel preparation with more predictable adverse effects of Meglumine-Diatrizoate with the 75:25 preparation. Implications for practice: Providing patients with a higher contrast burden 24 h prior to CTC may have a positive impact on the patient experience without compromising image quality. (C) 2020 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:E290 / E296
页数:7
相关论文
共 50 条
  • [1] COMPUTED BODY TOMOGRAPHY WITH A NEW NONIONIC CONTRAST AGENT COMPARISON OF IOVERSOL WITH SODIUM MEGLUMINE-DIATRIZOATE
    MCCLENNAN, BL
    HEIKEN, JP
    LEE, JKT
    JAMES, MA
    INVESTIGATIVE RADIOLOGY, 1989, 24 : S35 - S38
  • [2] Objective and Subjective Intrapatient Comparison of Iohexol Versus Diatrizoate for Bowel Preparation Quality at CT Colonography
    Johnson, Brandon
    Hinshaw, J. Louis
    Robbins, Jessica B.
    Pickhardt, Perry J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (06) : 1202 - 1207
  • [3] Preoperative bowel preparation with meglumine and sodium diatrizoate (Gastrografin): A prospective randomised comparison
    Koussidis, GA
    Koussidis, A
    EUROPEAN JOURNAL OF SURGERY, 2001, 167 (12) : 899 - 902
  • [4] IOPAMIDOL AND MEGLUMINE-DIATRIZOATE - COMPARISON OF EFFECTS ON PATIENT DISCOMFORT DURING AORTOFEMORAL ARTERIOGRAPHY
    WIDRICH, WC
    BECKMAN, CF
    ROBBINS, AH
    SCHOLZ, FJ
    SRINIVASAN, MK
    HAYES, EJ
    KELLUM, CD
    NEWMAN, T
    RADIOLOGY, 1983, 148 (01) : 61 - 64
  • [5] Bowel Preparation Regimen for Computed Tomography Colonography
    Behrens, Carola
    Eddy, Richard
    Stevenson, Giles
    Audet, Louise
    Mathieson, John
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2010, 61 (05): : 280 - 285
  • [6] COMPARISON OF BARIUM AND DIATRIZOATE BOWEL LABELING AGENTS IN COMPUTED-TOMOGRAPHY
    CARR, DH
    BANKS, LM
    BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (689): : 393 - 394
  • [7] Bowel preparation for CT colonography: Comparison of two different cleansing protocols
    Juchems, Markus S.
    Hoffmann, Martin H. K.
    Schmidt, Stefan A.
    Apostel, Anna
    Brambs, Hans-Juergen
    Aschoff, Andrik J.
    EUROPEAN JOURNAL OF RADIOLOGY, 2006, 60 (03) : 460 - 464
  • [8] ADJUSTED COMPARISON OF COMMERCIAL BOWEL PREPARATIONS BASED ON INADEQUACY OF BOWEL PREPARATION IN OUTPATIENT SETTINGS
    Sarvepalli, Shashank
    Garber, Ari
    Rizk, Maged
    Morris-Stiff, Gareth
    McMichael, John
    Rothberg, Michael
    Gupta, Niyati M.
    Burke, Carol A.
    GASTROINTESTINAL ENDOSCOPY, 2018, 87 (06) : AB127 - AB127
  • [9] EVALUATION OF GASTROMIRO FOR BOWEL OPACIFICATION DURING COMPUTED-TOMOGRAPHY - COMPARISON WITH DIATRIZOATE AND BARIUM-SULFATE
    DOYLE, GJ
    ODONNELL, SC
    MCDONALD, JR
    MURTHY, LNS
    KEIR, MJ
    WRIGHT, AR
    BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (788): : 681 - 684
  • [10] CT colonography with limited bowel preparation: prospective assessment of patient experience and preference in comparison to optical colonoscopy with cathartic bowel preparation
    Sebastiaan Jensch
    Shandra Bipat
    Jan Peringa
    Ayso H. de Vries
    Anneke Heutinck
    Evelien Dekker
    Lubbertus C. Baak
    Alexander D. Montauban van Swijndregt
    Jaap Stoker