Acoustic radiation force impulse (ARFI) elastography for the noninvasive diagnosis of liver fibrosis in children

被引:80
|
作者
Hanquinet, Sylviane [1 ,6 ]
Rougemont, Anne-Laure [2 ]
Courvoisier, Delphine [3 ,4 ]
Rubbia-Brandt, Laura [2 ]
Mclin, Valerie [5 ]
Tempia, Michela [5 ]
Anooshiravani, Mehrak [1 ]
机构
[1] Univ Hosp Geneva, Dept Pediat Radiol, Geneva, Switzerland
[2] Univ Hosp Geneva, Div Clin Pathol, Geneva, Switzerland
[3] Univ Geneva, Div Clin Epidemiol, Geneva, Switzerland
[4] Harvard Univ, Dept Psychol, Cambridge, MA 02138 USA
[5] Univ Hosp Geneva, Dept Pediat Gastroenterol, Geneva, Switzerland
[6] Hop Univ Enfants, Unite Radiopediat, CH-1211 Geneva 14, Switzerland
关键词
Liver fibrosis; ARFI elastography; Liver disease; Child; TRANSIENT ELASTOGRAPHY; MEDICAL-MANAGEMENT; CHRONIC HEPATITIS; PERFORMANCE; BIOPSY; FEASIBILITY; TECHNOLOGY; DISEASES; MARKERS; FOCUS;
D O I
10.1007/s00247-012-2595-8
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Acoustic radiation force impulse (ARFI) imaging) is correlated with histopathological findings using METAVIR and semiquantitative scoring system (SSS) criteria for liver fibrosis. To compare acoustic radiation force impulse imaging with biopsy results in the evaluation of liver fibrosis in children. Children with chronic liver disease and healthy children underwent acoustic radiation force impulse imaging liver measurements. ARFI gives a shear-wave velocity corresponding to tissue elasticity. In 39 children with liver disease, the values obtained were correlated with biopsy results. Receiver-operating characteristic (ROC) curves were used to determine the reliability of ARFI in estimating liver fibrosis in children. ARFI mean value was 1.12 in the healthy group and 1.99 in children with chronic liver disease. ROC curves show that an ARFI cutoff of 1.34 m/s is predictive of both METAVIR and SSS scores with a sensitivity of SSS > 2:0.85; METAVIR > F0:0.82. A cutoff of 2 m/s yielded a sensitivity of 100% to detect SSS > 4 or METAVIR > F2. Acoustic radiation force impulse imaging is a reliable, noninvasive and rapid method to estimate moderate to severe liver fibrosis in children. It might prove useful to clinicians for fibrosis monitoring in children with liver disease and postpone the time of liver biopsy.
引用
收藏
页码:545 / 551
页数:7
相关论文
共 50 条
  • [21] Acoustic Radiation Force Impulse (ARFI) - a new modality for the evaluation of liver fibrosis
    Sporea, Ioan
    Sirli, Roxana
    Popescu, Alina
    Danila, Mirela
    MEDICAL ULTRASONOGRAPHY, 2010, 12 (01) : 26 - 31
  • [22] Noninvasive acoustic radiation force impulse (ARFI) elastography for assessing the severity of fibrosis in the post-operative patients with biliary atresia
    Hideki Shima
    Gaku Igarashi
    Munechika Wakisaka
    Shiho Hamano
    Hideki Nagae
    Mariko Koyama
    Hiroaki Kitagawa
    Pediatric Surgery International, 2012, 28 : 869 - 872
  • [23] FACTORS INFLUENCING THE ACCURACY OF LIVER STIFFNESS MEASUREMENTS BY TRANSIENT ELASTOGRAPHY (TE) AND BY ACOUSTIC RADIATION FORCE IMPULSE (ARFI) ELASTOGRAPHY FOR LIVER FIBROSIS EVALUATION
    Bota, S.
    Sporea, I.
    Peck-Radosavljevic, M.
    Sirli, R.
    Saito, H.
    Ebinuma, H.
    Lupsor, M.
    Badea, R.
    Friedrich-Rust, M.
    Sarrazin, C.
    Piscaglia, F.
    Marinelli, S.
    Salzl, P.
    Popescu, A.
    Danila, M.
    JOURNAL OF HEPATOLOGY, 2013, 58 : S288 - S288
  • [24] Noninvasive acoustic radiation force impulse (ARFI) elastography for assessing the severity of fibrosis in the post-operative patients with biliary atresia
    Shima, Hideki
    Igarashi, Gaku
    Wakisaka, Munechika
    Hamano, Shiho
    Nagae, Hideki
    Koyama, Mariko
    Kitagawa, Hiroaki
    PEDIATRIC SURGERY INTERNATIONAL, 2012, 28 (09) : 869 - 872
  • [25] Intra and Interoperator Reproducibility of Acoustic Radiation Force Impulse Elastography (ARFI)
    Bota, Simona
    Sporea, Ioan
    Sirli, Roxana
    Popescu, Alina
    Danila, Mirela
    Sendroiu, Madalina
    Jurchis, Ana
    Martie, Alina F.
    Suseanu, Dragos
    GASTROENTEROLOGY, 2012, 142 (05) : S1002 - S1002
  • [26] Evaluation of Acoustic Radiation Force Elastography (ARFI) in the Diagnosis of Hepatic Fibrosis and Portal Hypertension
    Amarapurkar, Deepak
    Kashikar, Rupesh K.
    Lala, Somesh
    Gautam, Sonali
    Amarapurkar, Anjali D.
    GASTROENTEROLOGY, 2015, 148 (04) : S1031 - S1032
  • [27] Thyroid Stiffness Assessment by Acoustic Radiation Force Impulse Elastography (ARFI)
    Sporea, I.
    Vlad, M.
    Bota, S.
    Sirli, R. L.
    Popescu, A.
    Danila, M.
    Sendroiu, M.
    Zosin, I.
    ULTRASCHALL IN DER MEDIZIN, 2011, 32 (03): : 281 - 285
  • [28] Acoustic Radiation Force Impulse (ARFI) Elastography in Evaluation of Supraspinatus Tendinopathy
    Serifoglu, Ismail
    Guneyli, Serkan
    Oz, Ibrahim Ilker
    Tosun, Alptekin
    CURRENT MEDICAL IMAGING, 2023, 19 (06) : 631 - 635
  • [29] Liver Stiffness Measurement Using Acoustic Radiation Force Impulse (ARFI) Elastography and Effect of Necroinflammation
    Yoon, Ki Tae
    Lim, Sun Min
    Park, Jun Yong
    Kim, Do Young
    Ahn, Sang Hoon
    Han, Kwang-Hyub
    Chon, Chae Yoon
    Cho, Mong
    Lee, Jun Woo
    Kim, Seung Up
    DIGESTIVE DISEASES AND SCIENCES, 2012, 57 (06) : 1682 - 1691
  • [30] The importance of acoustic radiation force impulse (ARFI) elastography in the diagnosis and clinical course of acute pancreatitis
    Kaya, Muhsin
    Degirmenci, Serdar
    Goya, Cemil
    Tuncel, Elif Tuba
    Ucmakl, Feyzullah
    Kaplan, Mehmet Ali
    TURKISH JOURNAL OF GASTROENTEROLOGY, 2018, 29 (03): : 342 - 347