Prosthesis-patient mismatch after aortic valve replacement: Impact of age and body size on late survival

被引:105
|
作者
Moon, MR [1 ]
Pasque, MK [1 ]
Munfakh, NA [1 ]
Melby, SJ [1 ]
Lawton, JS [1 ]
Moazami, N [1 ]
Codd, JE [1 ]
Crabtree, TD [1 ]
Barner, HB [1 ]
Damiano, RJ [1 ]
机构
[1] Washington Univ, Sch Med, Div Cardiothorac Surg, St Louis, MO 63110 USA
来源
ANNALS OF THORACIC SURGERY | 2006年 / 81卷 / 02期
关键词
D O I
10.1016/j.athoracsur.2005.07.084
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The purpose of this study was to identify patient subgroups in which prosthesis-patient mismatch most influenced late survival. Methods. Over a 12-year period, 1,400 consecutive patients underwent bioprosthetic (933 patients) or mechanical (467) aortic valve replacement. Prosthesis-patient mismatch was defined as prosthetic effective orifice area/body surface area less than 0.75 cm(2)/m(2) and was present with 11% mechanical and 51% bioprosthetic valves. Results. With bioprosthetic valves, prosthesis-patient mismatch was associated with impaired survival for patients less than 60 years old (10-year: 68% +/- 7% mismatch versus 75% +/- 7% no mismatch, p < 0.02) but not older patients (p = 0.47). Similarly, with mechanical valves, prosthesis-patient mismatch was associated with impaired survival for patients less than 60 years old (10-year: 62% +/- 11% versus 79% +/- 4%, p < 0.005) but not older patients (p = 0.26). For small patients (body surface area less than 1.7 m(2)), prosthesis-patient mismatch did not impact survival with bioprosthetic (p = 0.32) or mechanical (p = 0.71) valves. For average-size patients (body surface area 1.7 to 2.1 m(2)), prosthesis-patient mismatch was associated with impaired survival with both bioprosthetic (p < 0.05) and mechanical (p < 0.005) valves. For large patients (body surface area greater than 2.1 m(2)), prosthesis-patient mismatch was associated with impaired survival with mechanical (p < 0.04) but not bioprosthetic (p = 0.40) valves. Conclusions. Prosthesis-patient mismatch had a negative impact on survival for young patients, but its impact on older patients was minimal. In addition, although prosthesis-patient mismatch was not important in small patients, prosthesis-patient mismatch negatively impacted survival for average-size patients and for large patients with mechanical valves.
引用
收藏
页码:481 / 489
页数:9
相关论文
共 50 条
  • [31] Relative prosthesis-patient mismatch after transcatheter aortic valve replacement: The impact of morbid obesity
    Airhart, Sophia
    Medvedev, Ivan
    Dean, Larry S.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (02) : 341 - 345
  • [32] Prosthesis-patient mismatch after surgical aortic valve replacement in patients with aortic stenosis
    Kim, Hee Jung
    Kim, Ho Jin
    Kim, Joon Bum
    Jung, Sung-Ho
    Choo, Suk Jung
    Chung, Cheol Hyun
    Lee, Jae Won
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2020, 31 (02) : 152 - 157
  • [33] Racial Differences in the Incidence and Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Park, Hanbit
    Ahn, Jung-Min
    Kang, Do-Yoon
    Kim, Juyong Brian
    Yeung, Alan C.
    Nishi, Takeshi
    Fearon, William F.
    Cantey, Eric Page
    Flaherty, James D.
    Davidson, Charles J.
    Malaisrie, S. Christopher
    Kim, Sehee
    Yun, Sung-Cheol
    Ko, Euihong
    Lee, Seung-Ah
    Kim, Dae-Hee
    Kim, Ho Jin
    Kim, Joon Bum
    Choo, Suk Jung
    Park, Duk-Woo
    Park, Seung-Jung
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (24) : 2670 - 2681
  • [34] Prosthesis-Patient Mismatch After "High-Risk" Aortic Valve Replacement
    Popma, Jeffrey J.
    Khabbaz, Kamal
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (13) : 1335 - 1338
  • [35] Clinical predictors of prosthesis-patient mismatch after aortic valve replacement for aortic stenosis
    Astudillo, Luis M.
    Santana, Orlando
    Urbandt, Pablo A.
    Benjo, Alexandre M.
    Elkayam, Lior U.
    Nascimento, Francisco O.
    Lamas, Gervasio A.
    Lamelas, Joseph
    CLINICS, 2012, 67 (01) : 55 - 60
  • [36] The Incidence and Consequence of Prosthesis-Patient Mismatch After Surgical Aortic Valve Replacement
    Fallon, John M.
    DeSimone, Joseph P.
    Brennan, J. Matthew
    O'Brien, Sean
    Thibault, Dylan P.
    DiScipio, Anthony W.
    Pibarot, Philippe
    Jacobs, Jeffrey P.
    Malenka, David J.
    Clarizia, Nadia A.
    Ruel, Marc
    ANNALS OF THORACIC SURGERY, 2018, 106 (01): : 14 - 23
  • [37] Overcoming prosthesis-patient mismatch with transcatheter aortic valve replacement
    Grubb, Kendra J.
    Tom, Stephanie K.
    Sultan, Ibrahim
    Sa, Michel Pompeu
    ANNALS OF CARDIOTHORACIC SURGERY, 2024, 13 (03) : 236 - 243
  • [38] Prosthesis-Patient Mismatch in the Transcatheter Aortic Valve Replacement Era
    Tuzcu, E. Murat
    Oezkan, Alper
    Kapadia, Samir R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (18) : 1919 - 1922
  • [39] Prosthesis-Patient Mismatch after Aortic Valve Replacement with the Mosaic Ultra Bioprosthesis
    Ntinopoulos, Vasileios
    Biefer, Hector Rodriguez Cetina
    Dushaj, Stak
    Rings, Laura
    Fleckenstein, Philine
    Dzemali, Omer
    Haeussler, Achim
    THORACIC AND CARDIOVASCULAR SURGEON, 2024, 72 (03): : 197 - 204
  • [40] Imaging for Predicting and Assessing Prosthesis-Patient Mismatch After Aortic Valve Replacement
    Pibarot, Philippe
    Magne, Julien
    Leipsic, Jonathon
    Cote, Nancy
    Blanke, Philippe
    Thourani, Vinod H.
    Hahn, Rebecca
    JACC-CARDIOVASCULAR IMAGING, 2019, 12 (01) : 149 - 162