Radiation dose reduction from low-kilovoltage liver computed tomography using multidetector row computed tomography

被引:0
|
作者
Cho, Pyong-Kon [1 ]
机构
[1] Catholic Univ Daegu, Dept Radiol Sci, Gyongsan, South Korea
关键词
LOW-TUBE VOLTAGE; CT;
D O I
10.1093/rpd/ncs153
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The primary goal of this study was to ascertain the reduction in radiation dose when conducting low-kilovoltage liver computed tomography (CT) examinations using multidetector row CT (MDCT). Fifty patients under follow-up who were diagnosed with liver cancer were examined using a 16-slice MDCT scanner and volume CT dose index (CTDIvol) measured according to the methods of examination, which were based on a three-phase CT scan conducted in the previous year and a four-phase CT scan was done a year later. Scanning parameters were 120 kV(p)140 mA s, 120 kV(p)120 mA s and 80 kV(p)280 mA s. The CTDIvol was decreased to 47 at 80 kV(p) 280 mA s. The results indicate that low-kilovoltage liver CT is a useful means of reducing radiation doses.
引用
收藏
页码:76 / 80
页数:5
相关论文
共 50 条
  • [21] Multidetector computed tomography (MDCT) and dose reduction in pediatric radiology
    Heyer, C. M.
    MONATSSCHRIFT KINDERHEILKUNDE, 2011, 159 (04) : 343 - 349
  • [22] Radiation dose reduction in hepatic multidetector computed tomography with a novel adaptive noise reduction filter
    Funama, Yoshinori
    Awai, Kazuo
    Miyazaki, Osamu
    Goto, Taiga
    Nakayama, Yoshiharu
    Shimamura, Masamitchi
    Hiraishi, Kumiko
    Hori, Shinichi
    Yamashita, Yasuyuki
    RADIATION MEDICINE, 2008, 26 (03): : 171 - 177
  • [23] Radiation dose reduction in hepatic multidetector computed tomography with a novel adaptive noise reduction filter
    Yoshinori Funama
    Kazuo Awai
    Osamu Miyazaki
    Taiga Goto
    Yoshiharu Nakayama
    Masamitchi Shimamura
    Kumiko Hiraishi
    Shinichi Hori
    Yasuyuki Yamashita
    Radiation Medicine, 2008, 26 : 171 - 177
  • [24] Patient dose from kilovoltage cone beam computed tomography imaging in radiation therapy
    Islam, Mohammad K.
    Purdie, Thomas G.
    Norrlinger, Bernhard D.
    Alasti, Hamideh
    Moseley, Douglas J.
    Sharpe, Michael B.
    Siewerdsen, Jeffrey H.
    Jaffray, David A.
    MEDICAL PHYSICS, 2006, 33 (06) : 1573 - 1582
  • [25] Ultra low dose quantification of coronary artery calcifications using multidetector-row computed tomography (MDCT)
    Jakobs, TF
    Becker, CR
    Wintersperger, BJ
    Suess, C
    Knez, A
    Reiser, MF
    RADIOLOGY, 2002, 225 : 630 - 630
  • [26] Noncoronary Applications of Cardiac Multidetector Row Computed Tomography
    Tops, Laurens F.
    Krishnan, Subramaniam C.
    Schuijf, Joanne D.
    Schalij, Martin J.
    Bax, Jeroen J.
    JACC-CARDIOVASCULAR IMAGING, 2008, 1 (01) : 94 - 106
  • [27] Coronary Stent Imaging with Multidetector Row Computed Tomography
    Joanne D. Schuijf
    Jeroen J. Bax
    J. Wouter Jukema
    Hildo J. Lamb
    Martijn S. Dirksen
    Ernst E. van der Wall
    Albert de Roos
    The International Journal of Cardiovascular Imaging, 2004, 20 : 341 - 344
  • [28] Detection of pannus by multidetector-row computed tomography
    Teshima, H
    Hayashida, N
    Enomoto, N
    Aoyagi, S
    Okuda, K
    Uchida, M
    ANNALS OF THORACIC SURGERY, 2003, 75 (05): : 1631 - 1633
  • [29] Coronary stent imaging with multidetector row computed tomography
    Schuijf, JD
    Bax, JJ
    Jukema, JW
    Lamb, HJ
    Dirksen, MS
    van der Wall, EE
    de Roos, A
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2004, 20 (04): : 341 - 344
  • [30] Multidetector Row Computed Tomography of Small Bowel Obstruction
    Desser, Terry S.
    Gross, Megan
    SEMINARS IN ULTRASOUND CT AND MRI, 2008, 29 (05) : 308 - 321