Radiation dose reduction from low-kilovoltage liver computed tomography using multidetector row computed tomography

被引:0
|
作者
Cho, Pyong-Kon [1 ]
机构
[1] Catholic Univ Daegu, Dept Radiol Sci, Gyongsan, South Korea
关键词
LOW-TUBE VOLTAGE; CT;
D O I
10.1093/rpd/ncs153
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The primary goal of this study was to ascertain the reduction in radiation dose when conducting low-kilovoltage liver computed tomography (CT) examinations using multidetector row CT (MDCT). Fifty patients under follow-up who were diagnosed with liver cancer were examined using a 16-slice MDCT scanner and volume CT dose index (CTDIvol) measured according to the methods of examination, which were based on a three-phase CT scan conducted in the previous year and a four-phase CT scan was done a year later. Scanning parameters were 120 kV(p)140 mA s, 120 kV(p)120 mA s and 80 kV(p)280 mA s. The CTDIvol was decreased to 47 at 80 kV(p) 280 mA s. The results indicate that low-kilovoltage liver CT is a useful means of reducing radiation doses.
引用
收藏
页码:76 / 80
页数:5
相关论文
共 50 条
  • [1] Multidetector Computed Tomography Chest Examinations With Low-Kilovoltage Protocols in Adults: Effect on Image Quality and Radiation Dose
    Kim, Mi Jung
    Park, Chul Hi
    Choi, Soo Jin
    Hwang, Kyung Hoon
    Kim, Hyung Sik
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (03) : 416 - 421
  • [2] Radiation dose in multidetector row computed tomography cardiac imaging
    Bae, KT
    Hong, C
    Whiting, BR
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (06) : 859 - 863
  • [3] Multidetector row computed tomography
    Cowan, Nigel
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2006, 88 (05) : 517 - 517
  • [4] Multidetector-row computed tomography
    El-Khoury, GY
    Bennett, DL
    Ondr, GJ
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2004, 12 (01) : 1 - 5
  • [5] Errors in multidetector row computed tomography
    M. A. Mazzei
    L. Volterrani
    La radiologia medica, 2015, 120 : 785 - 794
  • [6] Errors in multidetector row computed tomography
    Mazzei, M. A.
    Volterrani, L.
    RADIOLOGIA MEDICA, 2015, 120 (09): : 785 - 794
  • [7] Comparison of the Radiation Dose from Cone Beam Computed Tomography and Multidetector Computed Tomography in Examinations of the Hand
    Neubauer, J.
    Neubauer, C.
    Gerstmair, A.
    Krauss, T.
    Reising, K.
    Zajonc, H.
    Kotter, E.
    Langer, M.
    Fiebich, M.
    Voigt, J.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2016, 188 (05): : 488 - 493
  • [8] Radiation Dose Reduction in Cervical Spine Computed Tomography in Cervical Spine Trauma: Comparison of Low-dose with Standard-dose Multidetector Computed Tomography
    Man, K. Y.
    Mo, K. M.
    Sung, H. T.
    Cho, K. Y.
    Tam, C. W.
    HONG KONG JOURNAL OF RADIOLOGY, 2019, 22 (03): : 180 - 187
  • [9] Multidetector computed tomography of the liver
    Schima, W
    Kulinna, C
    Ba-Ssalamah, A
    Grünberger, T
    RADIOLOGE, 2005, 45 (01): : 15 - 23
  • [10] Automated Low-Kilovoltage Selection in Pediatric Computed Tomography Angiography Phantom Study Evaluating Effects on Radiation Dose and Image Quality
    Siegel, Marilyn Joy
    Ramirez-Giraldo, Juan Carlos
    Hildebolt, Charles
    Bradley, David
    Schmidt, Bernhard
    INVESTIGATIVE RADIOLOGY, 2013, 48 (08) : 584 - 589