Cancellation of Superficial Blood Flow in Brain Function Measurements Using Near-Infrared Spectroscopy

被引:0
|
作者
Fukuda, Keiko [1 ]
Motoyoshi, Daisuke
Sato, Daisuke [1 ]
机构
[1] Tokyo Metropolitan Coll Ind Technol, Arakawa Ku, 8-17-1 Minamisenjyu, Tokyo 1168523, Japan
关键词
SYSTEM;
D O I
10.1109/embc.2019.8857057
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In brain function measurement by near-infrared spectroscopy, reduction of signal fluctuation caused by the superficial blood flow is necessary. We proposed an equilateral-triangle-type sensor arrangement for cancelling superficial blood flow using short-distance detectors placed at the center of the triangle. We applied the independent components analysis (ICA) for this equilateral triangle configuration to improve the correction effect. We measured the change in blood volume caused by the motion artifacts according to the posture change and analyzed the correction effect of the ICA. It is shown that the ICA is more effective than simple subtraction and has small dependence on the measurement conditions and is applicable to this equilateral triangle configuration.
引用
收藏
页码:486 / 489
页数:4
相关论文
共 50 条
  • [21] Combining near-infrared spectroscopy and electroencephalography to monitor brain function
    Salvatori, Giorgia
    Bulf, Luca
    Fonda, Sergio
    Rovati, Luigi
    2006 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE PROCEEDINGS, VOLS 1-5, 2006, : 32 - +
  • [22] Near-Infrared spectroscopy to monitor peripheral blood flow perfusion
    Harel F.
    Denault A.
    Ngo Q.
    Dupuis J.
    Khairy P.
    Journal of Clinical Monitoring and Computing, 2008, 22 (1) : 37 - 43
  • [23] Skin blood flow affects in vivo near-infrared spectroscopy measurements in human skeletal muscle
    Buono, MJ
    Miller, PW
    Hom, C
    Pozos, RS
    Kolkhorst, FW
    JAPANESE JOURNAL OF PHYSIOLOGY, 2005, 55 (04): : 241 - 244
  • [24] The correlation between brain near-infrared spectroscopy and cerebral blood flow in piglets with intracranial hypertension
    Alosh, Humam
    Ramirez, Alma
    Mink, Richard
    JOURNAL OF APPLIED PHYSIOLOGY, 2016, 121 (01) : 255 - 260
  • [25] Respiratory and locomotor muscle blood flow measurements using near-infrared spectroscopy and indocyanine green dye in health and disease
    Megaritis, Dimitrios
    Echevarria, Carlos
    Vogiatzis, Ioannis
    CHRONIC RESPIRATORY DISEASE, 2024, 21
  • [26] Estimation of graft blood flow in rat lung transplantation using near-infrared spectroscopy
    Shibata, S
    Miyata, Y
    Ohdan, H
    Noriyuki, T
    Yoshioka, S
    Okimasa, S
    Asahara, T
    Ito, H
    Dohi, K
    TRANSPLANTATION PROCEEDINGS, 2000, 32 (07) : 2437 - 2438
  • [27] Cortical blood flow change in the primary headache: a study using near-infrared spectroscopy
    Hashimoto, K.
    Hirata, K.
    Kimoto, K.
    Niijima, Y.
    Tanaka, H.
    Watanabe, Yuka
    CEPHALALGIA, 2007, 27 (06) : 606 - 606
  • [28] Imaging Brain Function with Functional Near-Infrared Spectroscopy in Unconstrained Environments
    Balardin, Joana B.
    Zimeo Morais, Guilherme A.
    Furucho, Rogerio A.
    Trambaiolli, Lucas
    Vanzella, Patricia
    Biazoli, Claudinei, Jr.
    Sato, Joao R.
    FRONTIERS IN HUMAN NEUROSCIENCE, 2017, 11
  • [29] Prediction of brain tissue temperature using near-infrared spectroscopy
    Holper, Lisa
    Mitra, Subhabrata
    Bale, Gemma
    Robertson, Nicola
    Tachtsidis, Ilias
    NEUROPHOTONICS, 2017, 4 (02)
  • [30] Near-infrared spectroscopy of the thenar eminence to estimate forearm blood flow
    Woinarski, Nicholas C. Z.
    Suzuki, Satoshi
    Lipcsey, Miklos
    Lumsden, Natalie
    Chin-Dusting, Jaye
    Schneider, Antoine G.
    Bailey, Michael
    Bellomo, Rinaldo
    CRITICAL CARE AND RESUSCITATION, 2013, 15 (04) : 323 - 326