Comparison of dobutamine-stress magnetic resonance imaging and dipyridamole-Tl-201-SPECT as alternative strategies for the detection of coronary artery disease in patients not suitable for stress-echocardiography

被引:0
|
作者
Schmidt, M
Jochims, M
Theissen, P
Baer, FM
Crnac, J
Voth, E
Schneider, CA
Erdmann, E
Schicha, H
机构
[1] Univ Cologne, Nukl Med Klin & Poliklin, D-50924 Cologne, Germany
[2] Univ Cologne, Innere Med Klin 3, Cologne, Germany
来源
NUKLEARMEDIZIN-NUCLEAR MEDICINE | 2001年 / 40卷 / 06期
关键词
coronary artery disease; stress-echocardiography; magnetic resonance imaging; myocardial scintigraphy; Tl-201-SPECT; pharmacological stress testing;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: During the past decade stress-echocardiography has gained increasing popularity for detection of myocardial ischemia in patients with coronary artery disease. However, about 10% to 15% of the patients submitted for stress-echocardiography do not have an adequate acoustic window. The purpose of this study was to compare high-dose dobutamine-stress magnetic resonance imaging (dobutamine-MRI) with dipyridamole-TI-201-SPECT (dipyridamole-SPECT) as alternative strategies for detection of myocardial ischemia in patients with inadequate image quality by stress-echocardiography. Patients and Methods: Of 296 patients which were consecutively submitted to stress-echocardiography 45 patients (15%) had two or more segments that could not be evaluated according to the 16-segment-model of the American Society of Echocardiography. They underwent dobutamine-MRI and dipyridamole-SPELT studies, which were evaluated using a 28-segment modell. Myocardial segments were attributed to perfusion territories of the coronary arteries. The results of ischemia detection were compared to the results of coronary angiography (stenosis greater than or equal to 50%) Results: In comparison to coronary angiography dobutamine-MRI yielded a sensitivity of 87%, a specificity of 86%, a positive predictive value of 93%, a negative predictive value of 75% and a diagnostic accuracy of 86%. For dipyridamole-SPELT results were 90%, 86%, 93%, 80% and 89%, respectively. These values were not significantly different. Conclusions: In patients not suitable for stress-echocardiography, both dobutamine-MRI and dipyridamole-SPELT are reliable strategies for detection of myocardial ischemia. Selection is dependent on the patient criteria, technical considerations, local logistics and experience of the observer.
引用
收藏
页码:198 / 206
页数:13
相关论文
共 50 条
  • [31] Parallel imaging and dobutamine stress magnetic resonance imaging in patients with atypical chest pain or equivocal ECG not suitable for stress echocardiography
    Di Cesare, E.
    Battisti, S.
    Riva, A.
    Corbacelli, C.
    De Bernardinis, G.
    Cicogna, S.
    Masciocchi, C.
    RADIOLOGIA MEDICA, 2009, 114 (02): : 216 - 228
  • [32] Comparison of Dobutamine stress echocardiography with and without real-time perfusion imaging for detection of coronary artery disease
    Xie, F
    Tsutsui, JM
    McGrain, AC
    DeMaria, A
    Cotter, B
    Becher, H
    Lebleu, C
    Labovitz, A
    Picard, MH
    O'Leary, EL
    Porter, TR
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (04): : 506 - 511
  • [33] Dobutamine-atropine stress echocardiography and dipyridamole sestamibi scintigraphy for the detection of coronary artery disease: Limitations and concordance
    Smart, SC
    Bhatia, A
    Hellman, R
    Stoiber, T
    Krasnow, A
    Collier, BD
    Sagar, KB
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (04) : 1265 - 1273
  • [34] Comparison of exercise, dobutamine-atropine and dipyridamole-atropine stress echocardiography in detecting coronary artery disease
    Nedeljkovic I.
    Ostojic M.
    Beleslin B.
    Djordjevic-Dikic A.
    Stepanovic J.
    Nedeljkovic M.
    Stojkovic S.
    Stankovic G.
    Saponjski J.
    Petrasinovic Z.
    Giga V.
    Mitrovic P.
    Cardiovascular Ultrasound, 4 (1)
  • [35] SYNERGISTIC VALUE OF SIMULTANEOUS STRESS DOBUTAMINE SESTAMIBI SPECT AND ECHOCARDIOGRAPHY IN THE DETECTION OF CORONARY-ARTERY DISEASE
    SENIOR, R
    SRIDHARA, BS
    ANAGNOSTOU, E
    RAVAL, U
    HANDLER, CE
    RAFTERY, EB
    LAHIRI, A
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P16 - P16
  • [36] Detection of coronary artery disease in essential hypertensive patients by dobutamine - atropine stress echocardiography
    Miloradovic, VM
    Kojic, MK
    Filipovic, NF
    Jovic, MJ
    Iric-Cupic, VIC
    HYPERTENSION, 2003, 42 (04) : 640 - 640
  • [37] MAGNETIC-RESONANCE-IMAGING DURING DOBUTAMINE STRESS IN CORONARY-ARTERY DISEASE
    PENNELL, DJ
    UNDERWOOD, SR
    MANZARA, CC
    SWANTON, RH
    WALKER, JM
    ELL, PJ
    LONGMORE, DB
    AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (01): : 34 - 40
  • [38] DOBUTAMINE STRESS ECHOCARDIOGRAPHY - DETECTION OF CORONARY-ARTERY DISEASE IN PATIENTS WITH DILATED CARDIOMYOPATHY
    SHARP, SM
    SAWADA, SG
    SEGAR, DS
    RYAN, T
    KOVACS, R
    FINEBERG, NS
    FEIGENBAUM, H
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (04) : 934 - 939
  • [39] COMPARISON OF DIPYRIDAMOLE-DOPPLER ECHOCARDIOGRAPHY TO TL-201 IMAGING AND QUANTITATIVE CORONARY ARTERIOGRAPHY IN THE ASSESSMENT OF CORONARY-ARTERY DISEASE
    GRAYBURN, PA
    POPMA, JJ
    PRYOR, SL
    WALKER, BS
    SIMON, TR
    SMITHERMAN, TC
    AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (18): : 1315 - 1320
  • [40] Detection of coronary artery disease using real-time myocardial contrast echocardiography: Comparison with dipyridamole stress sestamibi SPECT
    Dawson, D
    Wei, K
    Thorpe, J
    Moos, S
    Dent, J
    Kaul, S
    CIRCULATION, 2000, 102 (18) : 540 - 540