Comparison of dobutamine-stress magnetic resonance imaging and dipyridamole-Tl-201-SPECT as alternative strategies for the detection of coronary artery disease in patients not suitable for stress-echocardiography

被引:0
|
作者
Schmidt, M
Jochims, M
Theissen, P
Baer, FM
Crnac, J
Voth, E
Schneider, CA
Erdmann, E
Schicha, H
机构
[1] Univ Cologne, Nukl Med Klin & Poliklin, D-50924 Cologne, Germany
[2] Univ Cologne, Innere Med Klin 3, Cologne, Germany
来源
NUKLEARMEDIZIN-NUCLEAR MEDICINE | 2001年 / 40卷 / 06期
关键词
coronary artery disease; stress-echocardiography; magnetic resonance imaging; myocardial scintigraphy; Tl-201-SPECT; pharmacological stress testing;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: During the past decade stress-echocardiography has gained increasing popularity for detection of myocardial ischemia in patients with coronary artery disease. However, about 10% to 15% of the patients submitted for stress-echocardiography do not have an adequate acoustic window. The purpose of this study was to compare high-dose dobutamine-stress magnetic resonance imaging (dobutamine-MRI) with dipyridamole-TI-201-SPECT (dipyridamole-SPECT) as alternative strategies for detection of myocardial ischemia in patients with inadequate image quality by stress-echocardiography. Patients and Methods: Of 296 patients which were consecutively submitted to stress-echocardiography 45 patients (15%) had two or more segments that could not be evaluated according to the 16-segment-model of the American Society of Echocardiography. They underwent dobutamine-MRI and dipyridamole-SPELT studies, which were evaluated using a 28-segment modell. Myocardial segments were attributed to perfusion territories of the coronary arteries. The results of ischemia detection were compared to the results of coronary angiography (stenosis greater than or equal to 50%) Results: In comparison to coronary angiography dobutamine-MRI yielded a sensitivity of 87%, a specificity of 86%, a positive predictive value of 93%, a negative predictive value of 75% and a diagnostic accuracy of 86%. For dipyridamole-SPELT results were 90%, 86%, 93%, 80% and 89%, respectively. These values were not significantly different. Conclusions: In patients not suitable for stress-echocardiography, both dobutamine-MRI and dipyridamole-SPELT are reliable strategies for detection of myocardial ischemia. Selection is dependent on the patient criteria, technical considerations, local logistics and experience of the observer.
引用
收藏
页码:198 / 206
页数:13
相关论文
共 50 条
  • [1] DOBUTAMINE STRESS ECHOCARDIOGRAPHY VERSUS DIPYRIDAMOLE SPECT ISONITRILE PERFUSION IMAGING FOR DETECTION OF CORONARY-ARTERY DISEASE
    WYNSEN, JC
    DUCHAK, JM
    SMART, SC
    POCHIS, WT
    BAMRAH, VS
    SAGAR, KB
    CIRCULATION, 1992, 86 (04) : 128 - 128
  • [2] COMPARISON OF DOBUTAMINE STRESS ECHOCARDIOGRAPHY TO DOBUTAMINE SPECT ISONITRILE PERFUSION IMAGING FOR DETECTION OF CORONARY-ARTERY DISEASE
    STOLBER, TR
    SMART, SC
    HELLMAN, RS
    WYNSEN, JC
    SAGAR, KB
    CLINICAL RESEARCH, 1993, 41 (03): : A641 - A641
  • [3] COMPARISON OF DOBUTAMINE STRESS ECHOCARDIOGRAPHY TO DOBUTAMINE SPECT ISONITRILE PERFUSION IMAGING FOR DETECTION OF CORONARY-ARTERY DISEASE
    STOLBER, TR
    SMART, SC
    HELLMAN, RS
    STAN, R
    WYNSEN, JC
    SAGAR, KB
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, : A55 - A55
  • [4] Dobutamine Stress Magnetic Resonance Imaging for Detection of Coronary Artery Disease
    van Rugge, F. Paul
    van der Wall, Ernst E.
    de Roos, Albert
    Bruschke, Albert V. G.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (02) : 431 - 439
  • [5] DETECTION OF INDIVIDUAL CORONARY STENOSES - COMPARISON OF DOBUTAMINE STRESS ECHOCARDIOGRAPHY WITH DIPYRIDAMOLE SPECT ISONITRILE PERFUSION IMAGING
    WYNSEN, JC
    STOIBER, TR
    SMART, SC
    HELLMAN, RS
    BAMRAH, VS
    SAGAR, KB
    CIRCULATION, 1993, 88 (04) : 558 - 558
  • [6] DETECTION OF INDIVIDUAL CORONARY STENOSES - COMPARISON OF DOBUTAMINE STRESS ECHOCARDIOGRAPHY WITH DIPYRIDAMOLE SPECT ISONITRILE PERFUSION IMAGING
    WYNSEN, JC
    STOIBER, TR
    SMART, SC
    HELLMAN, RS
    BAMRAH, VS
    SAGAR, KB
    CLINICAL RESEARCH, 1993, 41 (03): : A684 - A684
  • [7] Dobutamine stress magnetic resonance imaging for the detection of coronary artery disease in women
    Gebker, R.
    Jahnke, C.
    Hucko, T.
    Manka, R.
    Mirelis, J. G.
    Hamdan, A.
    Schnackenburg, B.
    Fleck, E.
    Paetsch, I.
    HEART, 2010, 96 (08) : 616 - 620
  • [8] DIPYRIDAMOLE TL-201 IMAGING VERSUS DOBUTAMINE ECHOCARDIOGRAPHY FOR THE EVALUATION OF CORONARY-ARTERY DISEASE IN PATIENTS UNABLE TO EXERCISE
    SIMEK, CL
    WATSON, DD
    SMITH, WH
    VINSON, E
    KAUL, S
    AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (17): : 1257 - 1262
  • [9] COMPARISON OF DOBUTAMINE STRESS ECHOCARDIOGRAPHY, DIPYRIDAMOLE STRESS ECHOCARDIOGRAPHY AND EXERCISE STRESS-TESTING FOR DIAGNOSIS OF CORONARY-ARTERY DISEASE
    PREVITALI, M
    LANZARINI, L
    FETIVEAU, R
    POLI, A
    FERRARIO, M
    FALCONE, C
    MUSSINI, A
    AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (12): : 865 - 870
  • [10] Simultaneous dobutamine stress echocardiography and thallium-201 perfusion imaging for the detection of coronary artery disease
    Huang, PJ
    Ho, YL
    Wu, CC
    Chao, CL
    Chen, MF
    Cheng, PU
    Lee, YT
    CARDIOLOGY, 1997, 88 (06) : 556 - 562