Image-based 3D dosimetric studies with high dose rate intracavitary brachytherapy of cervical cancer

被引:0
|
作者
Chakravarty, N. [1 ]
Semwal, M. K. [1 ]
Trivedi, G. [1 ]
Suhag, V [1 ]
Jain, M. [1 ]
Sharma, N. [1 ]
Vashisth, R. S. [1 ]
机构
[1] Army Hosp R&R, Radiat Oncol Ctr, New Delhi 110010, India
关键词
bladder and rectum dose; cervical cancer; high dose rate; intracavitary brachytherapy; BLADDER; RECTUM; VOLUME; RADIOTHERAPY; RADIOGRAPHY;
D O I
10.1017/S1460396919000712
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: To study 2D and 3D dosimetric values for bladder and rectum, and the influence of bladder volume on bladder dose in high dose rate (HDR) intracavitary brachytherapy (ICBT). The large patient data incorporated in this study would better represent the inherent variations in many parameters affecting dosimetry in HDR-ICBT. Material and Methods: We prospectively collected data for 103 consecutive cervical cancer patients (over 310 HDR fractions) undergoing CT-based HDR-ICBT at our centre. Correlation among bladder and rectum maximum volume doses and corresponding International Commission on Radiation Units and Measurement (ICRU) point doses were estimated and analysed. Impact of bladder volume on bladder maximum dose was assessed. Results: The ICRU point doses to bladder and rectum varied from the volumetric doses to these organs. Further, bladder volume poorly correlated with bladder maximum dose for volume variations encountered in the clinical practice at our centre. Findings: ICRU point doses to bladder and rectum are less likely to correlate with long-term toxicities to these organs. Further, in clinical practice where inter-fraction bladder volume does not vary widely there is no correlation between bladder volume and bladder dose.
引用
收藏
页码:277 / 280
页数:4
相关论文
共 50 条
  • [41] Correlation between (ICRU) point doses and CT based 3D image planning of intracavitary brachytherapy for cervical cancer
    Addeo, D.
    Duckworth, T.
    Blank, S.
    Hitchen, C.
    Donach, M.
    Formenti, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S374 - S374
  • [42] Transabdominal Ultrasonography Based High Dose Rate Conformal Intracavitary Brachytherapy in Cervical Carcinoma
    Nayak, A. S.
    Engineer, R.
    Mahantshetty, U. M.
    Sastri, S.
    Swamidas, J.
    Shrivastava, S.
    Sable, N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E304 - E304
  • [43] CT-based 3D Dose-Volume Parameter of the Rectum and Late Rectal Complication in Patients with Cervical Cancer Treated with High-Dose-Rate Intracavitary Brachytherapy
    Kato, Shingo
    Tran Dang Ngoc Linh
    Ohno, Tatsuya
    Nakano, Takashi
    Kiyohara, Hiroki
    Ohkubo, Yu
    Kamada, Tadashi
    JOURNAL OF RADIATION RESEARCH, 2010, 51 (02) : 215 - 221
  • [44] Incidence of Suboptimal Applicator Placement and the Resulting Dosimetric Impact in Image-Based Intracavitary Brachytherapy
    Rangarajan, Ramya
    JOURNAL OF MEDICAL PHYSICS, 2018, 43 (03) : 168 - 172
  • [45] Image guided radiation therapy boost in combination with high-dose-rate intracavitary brachytherapy for the treatment of cervical cancer
    Wang, Xianliang
    Li, Jie
    Wang, Pei
    Yuan, Ke
    Yin, Gang
    Wan, Bin
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2016, 8 (02) : 122 - 127
  • [46] Severe Gastrointestinal Complications in the Era of Image-guided High-dose-rate Intracavitary Brachytherapy for Cervical Cancer
    Trifiletti, Daniel M.
    Watkins, W. Tyler
    Duska, Linda
    Libby, Bruce B.
    Showalter, Timothy N.
    CLINICAL THERAPEUTICS, 2015, 37 (01) : 49 - 60
  • [47] Deep-learning-assisted automatic digitization of applicators in 3D CT image-based high-dose-rate brachytherapy of gynecological cancer
    Jung, Hyunuk
    Gonzalez, Yesenia
    Shen, Chenyang
    Klages, Peter
    Albuquerque, Kevin
    Jia, Xue
    BRACHYTHERAPY, 2019, 18 (06) : 841 - 851
  • [48] Image Guided Radiation Therapy Boost in Combination With High-Dose-Rate Intracavitary Brachytherapy for the Treatment of Cervical Cancer
    Wang, X.
    Wang, P.
    Li, J.
    Yuan, K.
    Yin, G.
    Wan, B.
    Lang, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E306 - E306
  • [49] Dosimetric Evaluation of Magnetic Resonance Image-guided Intracavitary Brachytherapy for Cervical Cancer
    Kim, Y.
    Lee, Y.
    Park, S.
    Jung, D.
    Kim, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S406 - S407
  • [50] Using MRI-Based Deformable Image Registration to Accumulate 3D Total Dose Distribution from Intracavitary Brachytherapy Fractions of Cervical Cancer
    Yu, Z.
    Richardson, S.
    Zhang, Y.
    Klopp, A.
    Dong, L.
    Mourtada, F.
    MEDICAL PHYSICS, 2010, 37 (06)