Solubility of R22, R23, R32, R134a, R152a, R125 and R744 refrigerants in water by using equations of state

被引:24
|
作者
Karamoddin, Maryam [1 ]
Varaminian, Farshad [1 ]
机构
[1] Semnan Univ, Sch Chem Gas & Petr Engn, Semnan, Iran
关键词
Parameters Binary interaction; Valderrama-Patel-Teja (VPT) equation of state; Cubic Plus Association (CPA) equation of state; Refrigerants Solubility in water; LIQUID-EQUILIBRIA; OF-STATE; DISSOCIATION; PREDICTION; METHANOL; HYDRATE; SYSTEMS; FLUIDS;
D O I
10.1016/j.ijrefrig.2013.04.013
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper tries to demonstrate the ability of VPT and CPA equations of state and modified mixing rules for predicting of solubility CHC1F(2) (R22), CHF3 (R23), CH2F2 (R32), C(2)H(2)F4 (R134a), C2H4F2 (R152a), C2HF5 (R125) and CO2 (R744) refrigerants in water at different temperatures and pressures. For this purpose, the fugacity of each component in gas and liquid phases is calculated by using VPT and CPA equations of state. Also in this work, the interaction parameters for mixing rules in each mixture are optimized by using two-phase equilibrium data (VLw). Results of the two-phase flash calculation show good agreement between obtained solubility and the experimental data. The predicted solubility of the selected refrigerants in water agrees with the experimental data with accuracy of about 1.5% and 3.5% by VPT equation of state modified mixing rule and CPA equation of state Van der Waals classic mixing rule respectively. Published by Elsevier Ltd.
引用
收藏
页码:1681 / 1688
页数:8
相关论文
共 50 条
  • [31] 混合工质R134a/R23替代R22的可行性研究
    王大鹏
    田琦
    李风雷
    能源与节能, 2011, (08) : 67 - 70
  • [32] Comparative investigation and multi objective design optimization of R744/R717, R744/R134a and R744/R1234yf cascade rerfigeration systems
    Mert Sinan Turgut
    Oguz Emrah Turgut
    Heat and Mass Transfer, 2019, 55 : 445 - 465
  • [33] EXPERIMENTAL PERFORMANCE OF R134a AND R152a USING MICROCHANNEL CONDENSER
    Bhatkar, V. W.
    Kriplani, V. M.
    Awari, G. K.
    JOURNAL OF THERMAL ENGINEERING, 2015, 1 (07): : 575 - 582
  • [34] Vapour-liquid equilibrium of ternary mixtures of the refrigerants R125, R143a and R134a
    Nagel, M
    Bier, K
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1996, 19 (04): : 264 - 271
  • [35] THERMAL-CONDUCTIVITY OF REFRIGERANTS R123, R134A, AND R125 AT LOW-TEMPERATURES
    TSVETKOV, OB
    LAPTEV, YA
    ASAMBAEV, AG
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 1994, 15 (02) : 203 - 214
  • [36] Single stage absorption system based on refrigerants R125 and R134a with DMETEG
    Levy, A
    Jelinek, M
    Borde, I
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2001, 47 (08): : 497 - 500
  • [37] Equations of state for mixtures of R-32, R-125, R-134a, R-143a, and R-152a
    Lemmon, EW
    Jacobsen, RT
    JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 2004, 33 (02) : 593 - 620
  • [38] Simulation research of a hybrid heat source heat pump using R134a, R744 instead of R22 for domestic water heating in residential buildings
    Li, Shanshan
    Li, Shuhong
    Zhang, Xiaosong
    ENERGY AND BUILDINGS, 2015, 91 : 57 - 64
  • [39] Experimental Investigation of an Automotive Air Conditioning System Using R444A and R152a Refrigerants as Alternatives of R134a
    Direk, Mehmet
    Mert, Mehmet Selcuk
    Soylu, Eren
    Yuksel, Fikret
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2019, 65 (04): : 212 - 218
  • [40] On insulation performance and flammability of R32/R134a
    Xi'an Jianzhu Keji Daxue Xuebao, 3 (277-280):