Experimental Assessment of a Variable Orifice Flowmeter for Respiratory Monitoring

被引:31
|
作者
Tardi, Giuseppe [1 ]
Massaroni, Carlo [1 ]
Saccomandi, Paola [1 ]
Schena, Emiliano [1 ]
机构
[1] Univ Campus Biomed Roma, I-00128 Rome, Italy
关键词
FLOW; IMPROVE; VOLUME; AIRWAY; METER;
D O I
10.1155/2015/752540
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Accurate measurement of gas exchanges is essential in mechanical ventilation and in respiratory monitoring. Among the large number of commercial flowmeters, only few kinds of sensors are used in these fields. Among them, variable orifice meters (VOMs) show some valuable characteristics, such as linearity, good dynamic response, and low cost. This paper presents the characterization of a commercial VOM intended for application in respiratory monitoring. Firstly, two nominally identical VOMs were calibrated within +10 L.min(-1), to assess their metrological properties. Furthermore, experiments were performed by humidifying the air, to evaluate the influence of vapor condensation on sensor's performances. The condensation influence was investigated during two long lasting trials (i.e., 4 hours) by delivering 4 L.min(-1) and 8 L.min(-1). Data show that the two VOMs' responses are linear and their response is comparable (sensitivity difference of 1.4%, RMSE of 1.50 Pa); their discrimination threshold is <0.5 L.min(-1), and the settling time is about 66 ms. The condensation within the VOM causes a negligible change in sensor sensitivity and a very slight deterioration of precision. The good static and dynamic properties and the low influence of condensation on sensor's response make this VOM suitable for applications in respiratory function monitoring.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Assessment of respiratory rate monitoring in the emergency department
    Lee, John H.
    Nathanson, Larry A.
    Burke, Ryan C.
    Anthony, Brian W.
    Shapiro, Nathan I.
    Dagan, Alon S.
    JOURNAL OF THE AMERICAN COLLEGE OF EMERGENCY PHYSICIANS OPEN, 2024, 5 (03)
  • [42] MEASUREMENT ACCURACY IN VARIABLE-AREA FLOWMETER
    LUTZ, K
    ARCHIV FUR TECHNISCHES MESSEN UND INDUSTRIELLE MESSTECHNIK, 1971, (421): : 13 - &
  • [43] Numerical Analysis of Orifice Chamfer Effects on Performance of Balanced Flowmeter for Cryogenic Fluids
    Chen H.
    Gao X.
    Wang J.
    Liu Y.-L.
    Jin T.
    Tuijin Jishu/Journal of Propulsion Technology, 2020, 41 (02): : 423 - 430
  • [44] Investigation of the Contamination Influence on the Parameters of Gas Flow Through Multihole Orifice Flowmeter
    Hasecic, Amra
    Imamovic, Jasmina
    Bikic, Sinisa
    Dzaferovic, Ejub
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [45] Accurate conductance measurements of a pinhole orifice using a constant-pressure flowmeter
    Fedchak, James A.
    Defibaugh, Dana R.
    MEASUREMENT, 2012, 45 (10) : 2449 - 2451
  • [46] NONINVASIVE MONITORING OF RESPIRATORY VOLUME - EXPERIMENTAL EVALUATION OF A BREATH MONITORING DEVICE
    AMIN, HM
    CIGADA, M
    FORDYCE, WE
    CAMPORESI, EM
    ANAESTHESIA, 1993, 48 (07) : 608 - 610
  • [47] A STRAIN GAUGE-VARIABLE AREA FLOWMETER
    GUILLAUME, DW
    DEVRIES, D
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (05): : 1522 - 1524
  • [48] PLANAR FLUIDIC FLOWMETER APPLICABLE TO RESPIRATORY FLOWS
    PARKER, GA
    HAY, AE
    JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 1977, 99 (04): : 293 - 299
  • [49] Investigation of the Contamination Influence on the Parameters of Gas Flow Through Multihole Orifice Flowmeter
    Hasecic, Amra
    Imamovic, Jasmina
    Bikic, Sinisa
    Dzaferovic, Ejub
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [50] HEMODYNAMIC ASSESSMENT OF EXPERIMENTAL RESPIRATORY DISTRESS SYNDROME
    GERSONY, WM
    DANIEL, SS
    MORISHIM.HO
    JAMES, LS
    KOHL, S
    PEDIATRIC RESEARCH, 1972, 6 (04) : 404 - &