Real-time patient radiation dosimeter for use in interventional radiology

被引:31
|
作者
Chida, Koichi [1 ,2 ]
Kato, Mamoru [3 ]
Inaba, Yohei [1 ,2 ]
Kobayashi, Ryota [2 ]
Nakamura, Masaaki [1 ]
Abe, Yoshihisa [4 ]
Zuguchi, Masayuki [1 ]
机构
[1] Tohoku Univ, Grad Sch Med, Dept Radiol Technol, Aoba Ku, 2-1 Seiryo, Sendai, Miyagi 9808575, Japan
[2] Tohoku Univ, Int Res Inst Disaster Sci, Div Disaster Med Sci, 6-6-4 Aoba, Sendai, Miyagi 9808579, Japan
[3] Res Inst Brain & Blood Vessels, Dept Radiol & Nucl Med, 6-17 Senshukubota, Akita 0100874, Japan
[4] Res Inst Brain & Blood Vessels, Div Internal Med, Dept Cardiol, 6-17 Senshukubota, Akita 0100874, Japan
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2016年 / 32卷 / 11期
基金
日本学术振兴会;
关键词
X-ray fluoroscopy; Interventional radiology (IR); Real-time monitoring; Radiation dose; Dosimeter; Fluoroscopically guided interventional procedure; FOLLOW-UP; SKIN;
D O I
10.1016/j.ejmp.2016.10.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
There is currently no effective real-time patient dosimeter available for use in interventional radiology (IR). We conducted a feasibility study in a clinical setting to investigate the use of the new dosimeter using photoluminescence sensors during procedures. Reference dosimeters were set at almost the same position of the prototype dosimeter sensors. We found excellent correlations between the reference measurements and those of the prototype dosimeter (r(2) = 0.950). The sensor of the new dosimeter does not interfere with the IR procedure. The new dosimeter will be an effective tool for the real-time measurement of patient skin doses during IR. (C) 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1475 / 1478
页数:4
相关论文
共 50 条
  • [41] Development of a Real-Time Gamma Dosimeter of High Sensitivity
    Sharma, S. L.
    Maity, T. K.
    Kumar, G. Anil
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 341 - +
  • [42] Occupational dosimetry in real time. Benefits for interventional radiology
    Vano, E.
    Fernandez, J. M.
    Sanchez, R.
    RADIATION MEASUREMENTS, 2011, 46 (11) : 1262 - 1265
  • [43] Characterization of Phosphorescent Strontium Aluminate as a Real-Time Dosimeter
    Drehmel, S.
    Mathew, D.
    Ehler, E.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [44] Radiation risks in interventional radiology
    Dendy, P. P.
    BRITISH JOURNAL OF RADIOLOGY, 2008, 81 (961): : 1 - 7
  • [45] Radiation protection in interventional radiology
    Johnson, DR
    Kyriou, J
    Morton, EJ
    Clifton, A
    Fitzgerald, M
    MacSweeney, E
    CLINICAL RADIOLOGY, 2001, 56 (02) : 99 - 106
  • [46] Radiation protection in interventional radiology
    Faulkner, K
    BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (832): : 325 - 326
  • [47] Interventional radiology and radiation therapy
    Janaki, Hadjiev
    ORVOSI HETILAP, 2015, 156 (17) : 706 - 710
  • [48] Radiation exposure in interventional radiology
    Pinto, N. G. V.
    Braz, D.
    Vallim, M. A.
    Filho, L. G. P.
    Azevedo, F. S.
    Barroso, R. C.
    Lopes, R. T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 586 - 590
  • [49] Radiation Protection in Interventional Radiology
    Garg, Tushar
    Shrigiriwar, Apurva
    INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2021, 31 (04): : 939 - 945
  • [50] Use of “Time-Out” checklist in interventional radiology procedures as a tool to enhance patient safety
    Rocco Corso
    Francesco Vacirca
    Chiara Patelli
    Davide Leni