Portable exhaled nitric oxide measurement - Comparison with the "gold standard" technique

被引:140
|
作者
Menzies, Daniel [1 ]
Nair, Arun [1 ]
Lipworth, Brian J. [1 ]
机构
[1] Univ Dundee, Asthma & Allergy Res Grp, Ninewells Hosp & Med Sch, Dundee DD1 9SY, Scotland
关键词
asthma; exhaled nitric oxide;
D O I
10.1378/chest.06-1335
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The measurement of fractional exhaled nitric oxide (FENO) can assist in the diagnosis of asthma and may also act as a useful surrogate inflammatory marker on which to base treatment decisions in asthma management algorithms. Until recently, this technique was confined to research facilities and secondary care institutions. A portable nitric oxide analyzer (MINO; Aerocrine AB; Smidesvagen, Sweden) has been developed, but few data exist comparing this device with established, larger laboratory-based analyzers (NIOX; Aerocrine AB). Methods: A total of 101 asthmatic patients (64 treated with regular inhaled corticosteroids) and 50 healthy volunteers had simultaneous FENO measurements undertaken using NIOX and MINO devices. Results: In both asthmatic patients and healthy volunteers, there was a good correlation between the measurements obtained using each device (r = 0.94 and 0.96, respectively). Altman-Bland plots confirmed this agreement. Receiver operating characteristic curves discriminating asthmatic patients from healthy volunteers obtained using the NIOX and MINO showed a sensitivity of 83.2% and a specificity of 72% using cutoff values of 13 and 12.5 parts per billion, respectively. Conclusion: FENO values obtained using a portable analyzer correlate well with those obtained using an established laboratory analyzer and can be used to discriminate asthmatic from nonasthmatic patients. This may facilitate the measurement of asthmatic airway inflammation in primary care.
引用
收藏
页码:410 / 414
页数:5
相关论文
共 50 条
  • [21] EXHALED NITRIC OXIDE MEASUREMENT: IS IT USEFUL IN CHILDREN?
    Chang, Anne B.
    RESPIROLOGY, 2010, 15 : 25 - 25
  • [22] MEASUREMENT OF EXHALED NITRIC-OXIDE IN MAN
    BORLAND, C
    COX, Y
    HIGENBOTTAM, T
    THORAX, 1993, 48 (11) : 1160 - 1162
  • [23] Measurement of exhaled nitric oxide in humans and animals
    Bernareggi, M
    Cremona, G
    PULMONARY PHARMACOLOGY & THERAPEUTICS, 1999, 12 (06) : 331 - 352
  • [24] Measurement of exhaled nitric oxide in healthy subjects
    Gomez, FP
    Palli, GM
    Barbera, JA
    Roca, J
    Rodriguez-Roisin, R
    MEDICINA CLINICA, 1998, 111 (01): : 1 - 5
  • [25] Measurement of exhaled nitric oxide in children, 2001
    Baraldi, E
    de Jongste, JC
    EUROPEAN RESPIRATORY JOURNAL, 2002, 20 (01) : 223 - 237
  • [26] Influence of atmospheric nitric oxide concentration on the measurement of nitric oxide in exhaled air
    Corradi, M
    Pelizzoni, A
    Majori, M
    Cuomo, A
    de' Munari, E
    Pesci, A
    THORAX, 1998, 53 (08) : 673 - 676
  • [27] Clinical Utility Of The Exhaled Nitric Oxide (NO) Measurement With Portable Devices In The Management Of Allergic Airway Inflammation And Asthma
    Sy Duong-Quy
    JOURNAL OF ASTHMA AND ALLERGY, 2019, 12 : 331 - 341
  • [28] Diagnosing asthma in general practice with portable exhaled nitric oxide measurement – results of a prospective diagnostic study
    Antonius Schneider
    Lisa Tilemann
    Tjard Schermer
    Lena Gindner
    Gunter Laux
    Joachim Szecsenyi
    Franz Joachim Meyer
    Respiratory Research, 10
  • [29] Diagnosing asthma in general practice with portable exhaled nitric oxide measurement - results of a prospective diagnostic study
    Schneider, Antonius
    Tilemann, Lisa
    Schermer, Tjard
    Gindner, Lena
    Laux, Gunter
    Szecsenyi, Joachim
    Meyer, Franz Joachim
    RESPIRATORY RESEARCH, 2009, 10
  • [30] Comparison Of Fractional Exhaled Nitric Oxide Measurements Using A Portable Analyzer (niox Mino) And A Standard Stationary Analyzer (noa280i)
    Arai, R.
    Ishii, Y.
    Shiobara, T.
    Hayashi, Y.
    Chibana, K.
    Fukuda, T.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187