摘要
Hollow structural steel (HSS) columns filled with concrete offer a number of benefits and are often used in tall buildings and other industrial structures. A mathematical model was developed and used to investigate the influence of important parameters that determine the fire resistance of concrete-filled hollow steel columns. The behavior of concrete-filled HSS columns with or without fire protection subjected to axial or eccentric loads was experimentally investigated and the results presented in this paper. The parametric and experimental studies provide information for the development of formulas for the calculation of the fire resistance and fire protection thickness of the composite columns. The main objectives of this work were threefold: First, to report a series of fire tests on composite columns; second, to analyze the influence of several parameters, such as the sectional dimension, load eccentricity ratio, and fire protection thickness on the fire resistance of the composite columns. It was found, in general, that the sectional dimension and the fire protection thickness have significant influence on the fire resistance of concrete-filled HSS columns; however, the load eccentricity ratio has moderate influence on the fire resistance. The final objective was to develop formulas for the calculation of the fire resistance and the fire protection thickness of the concrete-filled HSS columns.
引用
收藏
页码:346 / 356
页数:11
相关论文
共 50 条
  • [41] Experimental data analysis of concrete-filled steel columns
    Goode, C. Douglas
    Kuranovas, Artiomas
    Kvedaras, Audronis Kazimieras
    9TH INTERNATIONAL CONFERENCE: MODERN BUILDING MATERIALS, STRUCTURES AND TECHNIQUES, VOLS 1-3, 2008, : 546 - +
  • [42] An experimental behaviour of concrete-filled steel tubular columns
    Zeghiche, J
    Chaoui, K
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2005, 61 (01) : 53 - 66
  • [43] Behavior and calculation on concrete-filled steel CHS (circular hollow section) beam-columns
    Han, LH
    Yao, GH
    Zhao, XL
    STEEL AND COMPOSITE STRUCTURES, 2004, 4 (03): : 169 - 188
  • [44] Experimental study on ductility of square concrete-filled steel tube columns
    Du Xikai
    Wang Tiecheng
    Shen Dongjian
    Zhang Zhenkun
    8th International Conference on Steel-Concrete Composite and Hybrid Structures, Proceedings, 2006, : 73 - 78
  • [45] Strength Calculation of Short Concrete-filled Steel Tube Columns
    Anatoly Leonidovich Krishan
    Mariia Anatolyevna Astafeva
    Elvira Petrovna Chernyshova
    International Journal of Concrete Structures and Materials, 2018, 12
  • [46] Strength Calculation of Short Concrete-filled Steel Tube Columns
    Krishan, Anatoly Leonidovich
    Astafeva, Mariia Anatolyevna
    Chernyshova, Elvira Petrovna
    INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, 2018, 12 (01)
  • [47] Buckling of concrete filled steel hollow columns in case of fire
    University of Coimbra, Portugal
    不详
    Proc. SDSS' Rio: Int. Colloquium Stability and Ductility of Steel Structures, (481-488):
  • [48] RESEARCH ON FIRE RESISTANCE AND ON CALCULATION METHOD FOR FIRE PROTECTION THICKNESS OF SPECIAL-SHAPED CONCRETE-FILLED STEEL TUBULAR (CFST) COLUMNS
    Wei X.
    Yang Y.-L.
    Liu J.-P.
    Wang W.-Y.
    Yang W.-Q.
    Gongcheng Lixue/Engineering Mechanics, 2023, 40 (05): : 204 - 216and256
  • [49] Fire behaviour of fire-protected concrete-filled steel tubular columns
    Lou, Guo-Biao
    Tan, Rui-Xin
    Qi, Hong-Hui
    Rao, Wen-Ting
    Huang, Dai-Fa
    Zhao, Xin
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2025, 226
  • [50] FIRE RESISTANCE OF CONCRETE-FILLED STRUCTURAL HOLLOW SECTIONS.
    Anon
    Fire prevention science and technology, 1980, (23): : 15 - 17