The relationship between bispectral index and electroencephalographic parameters during isoflurane anesthesia

被引:88
|
作者
Morimoto, Y [1 ]
Hagihira, S
Koizumi, Y
Ishida, K
Matsumoto, M
Sakabe, T
机构
[1] Yamaguchi Univ, Sch Med, Dept Anesthesiol Resuscitol, Yamaguchi 7558505, Japan
[2] Osaka Prefectural Habikino Hosp, Dept Anesthesiol, Osaka, Japan
来源
ANESTHESIA AND ANALGESIA | 2004年 / 98卷 / 05期
关键词
D O I
10.1213/01.ANE.0000105867.17108.B6
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Bispectral index (BIS) integrates various electroencephalographic (EEG) parameters into a single variable. However, the exact algorithm used to synthesize the parameters to BIS values is not known. The relationship between BIS and EEG parameters was evaluated during nitrous oxide/isoflurane anesthesia. Twenty patients scheduled for elective ophthalmic surgery were enrolled in the study. After EEG recording with a BIS monitor (A-1050) was begun, general anesthesia was induced and maintained with 0.5%-2% isoflurane and 66% nitrous oxide. Using software we developed, we continuously recorded BIS, spectral edge frequency 95% (SEF95), and EEG parameters such as relative beta ratio (BetaRatio), relative synchrony of fast and slow wave (SynchFastSlow), and burst suppression ratio. BetaRatio was linearly correlated with BIS (r = 0.90; P < 0.01; n = 253) at BIS more than 60. At a BIS range of 30 to 80, SynchFastSlow (r = 0.60; P < 0.01; n = 3314) and SEF95 (r = 0.75; P < 0.01; n = 3339) were linearly correlated with BIS. The correlation between BIS and SEF95 was significantly better than the correlation between BIS and SynchFastSlow (P < 0.01). At BIS less than 30, the burst suppression ratio was inversely linearly correlated with BIS (r = 0.76; P < 0.01; n = 65). At BIS less than 80, burst-compensated SEF95 was linearly correlated with BIS (r = 0.78; P < 0.01; n = 3404). In the range of BIS from 60 to 100, BIS can be calculated from BetaRatio. At surgical levels of anesthesia, BIS and SynchFastSlow (a parameter derived from bispectral analysis) or burst-compensated SEF95 (derived from power spectral analysis) are well correlated. However, our results show that SynchFastSlow has no advantage over SEF95 in calculation of BIS.
引用
收藏
页码:1336 / 1340
页数:5
相关论文
共 50 条
  • [41] Determination of Propofol and Isoflurane Anesthesia Depth with Bispectral Index Monitorization in Dogs Undergoing Ovariohysterectomy Procedure
    Saritas, Zulfikar Kadir
    Saritas, Tuba Berra
    Yilmaz, Oktay
    Korkmaz, Musa
    KAFKAS UNIVERSITESI VETERINER FAKULTESI DERGISI, 2014, 20 (02) : 195 - 199
  • [42] Relationship between Bispectral Index Values and Volatile Anesthetic Concentrations during the Maintenance Phase of Anesthesia in the B-Unaware Trial
    Whitlock, Elizabeth L.
    Villafranca, Alexander J.
    Lin, Nan
    Palanca, Ben J.
    Jacobsohn, Eric
    Finkel, Kevin J.
    Zhang, Lini
    Burnside, Beth A.
    Kaiser, Heiko A.
    Evers, Alex S.
    Avidan, Michael S.
    ANESTHESIOLOGY, 2011, 115 (06) : 1209 - 1218
  • [43] The Bispectral Index in children: comparing isoflurane and halothane
    Davidson, AJ
    Czarnecki, C
    BRITISH JOURNAL OF ANAESTHESIA, 2004, 92 (01) : 14 - 17
  • [44] Reduced isoflurane consumption with bispectral index monitoring
    Guignard, B
    Coste, C
    Menigaux, C
    Chauvin, M
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2001, 45 (03) : 308 - 314
  • [45] The Bispectral Index: A guide to the depth of anesthesia during spine surgery
    Urban, MK
    Urquhart, B
    ANESTHESIOLOGY, 2000, 93 (3A) : U147 - U147
  • [46] Bispectral EEG index during general anesthesia for caesarean section
    Bryssine, B
    Allaouchiche, B
    Chassard, D
    ANESTHESIOLOGY, 2000, 93 (3A) : U214 - U214
  • [47] Monitoring oxygenator expiratory isoflurane concentrations and the bispectral index to guide isoflurane requirements during cardiopulmonary bypass
    Liu, EHC
    Dhara, SS
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2005, 19 (04) : 485 - 487
  • [48] Does bispectral EEG analysis change isoflurane administration during anesthesia in surgical patients?
    Guignard, B
    Menigaux, C
    Coste, C
    Chauvin, M
    ANESTHESIOLOGY, 1997, 87 (03) : A447 - A447
  • [49] Relationship between clinical endpoints for induction of anesthesia and bispectral index and effect-site concentration values
    Kim, DW
    Kil, HY
    White, PF
    JOURNAL OF CLINICAL ANESTHESIA, 2002, 14 (04) : 241 - 245
  • [50] The dynamic relationship between end-tidal sevoflurane and isoflurane concentrations and bispectral index and spectral edge frequency of the electroencephalogram
    Olofsen, E
    Dahan, A
    ANESTHESIOLOGY, 1999, 90 (05) : 1345 - 1353