Prediction and Measurement of Temperature Rise Induced by High Intensity Focused Ultrasound in a Tissue-Mimicking Phantom

被引:1
|
作者
Lee, Kang Il [1 ]
机构
[1] Kangwon Natl Univ, Dept Phys, Chunchon 24341, South Korea
基金
新加坡国家研究基金会;
关键词
High intensity focused ultrasound; Tissue-mimicking phantom; Temperature rise; Khokhlov-Zabolotskaya-Kuznetsov equation; Pennes' bioheat transfer equation; THERMAL ABLATION; SIMULATION; CAVITATION;
D O I
10.3938/jkps.72.1313
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The present study aims to predict the temperature rise induced by high intensity focused ultrasound (HIFU) in soft tissues to assess tissue damage during HIFU thermal therapies. With the help of a MATLAB-based software package developed for HIFU simulation, the HIFU field was simulated by solving the axisymmetric Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation from the frequency-domain perspective, and the HIFU-induced temperature rise in a tissue-mimicking phantom was simulated by solving Pennes' bioheat transfer (BHT) equation. In order to verify the simulation results, we performed in-vitro heating experiments on a tissue-mimicking phantom by using a 1.1-MHz, single-element, spherically focused HIFU transducer. The temperature rise near the focal spot obtained from the HIFU simulator was in good agreement with that from the in-vitro experiments. This confirms that the HIFU simulator based on the KZK and the BHT equations captures the HIFU-induced temperature rise in soft tissues well enough to make it suitable for HIFU treatment planning.
引用
收藏
页码:1313 / 1319
页数:7
相关论文
共 50 条
  • [41] Acoustic waves in hydrogels: A bi-phasic model for ultrasound tissue-mimicking phantom
    Chiarelli, Piero
    Lanata, Antonio
    Carbone, Marina
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2009, 29 (03): : 899 - 907
  • [42] Ultrasound tissue-mimicking materials using oil gel and measurement of their characteristics
    Kondo, Toshio
    Fujimoto, Hiroyuki
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 2002, 41 (5 B): : 3598 - 3599
  • [43] Quality Assurance for Ultrasound Scanners using a durable tissue-mimicking Phantom and radial MTF
    Kaar, Marcus
    Semturs, Friedrich
    Figl, Michael
    Hoffmann, Rainer
    Hummel, Johann
    MEDICAL IMAGING 2014: ULTRASONIC IMAGING AND TOMOGRAPHY, 2014, 9040
  • [44] Ultrasound tissue-mimicking materials using oil gel and measurement of their characteristics
    Kondo, T
    Fujimoto, H
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2002, 41 (5B): : 3598 - 3599
  • [45] Non-contact measurement of propagation speed in tissue-mimicking phantom using pass-through airborne ultrasound
    Hirata, Shinnosuke
    Haritaipan, Lalita
    Hoshiba, Kotaro
    Hachiya, Hiroyuki
    Niimi, Nobuo
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2014, 53 (07)
  • [46] Temperature Measurement Using Passive Harmonics during High Intensity Focused Ultrasound Exposures in Porcine Tissue
    Dong, Hu
    Qian, Shengyou
    Tan, Qiaolai
    Zou, Xiao
    Liu, Bei
    ACTA PHYSICA POLONICA A, 2018, 134 (02) : 524 - 528
  • [47] ULTRASOUND-INDUCED BUBBLE CLUSTERS IN TISSUE-MIMICKING AGAR PHANTOMS
    Movahed, Pooya
    Kreider, Wayne
    Maxwell, Adam D.
    Dunmire, Barbrina
    Freund, Jonathan B.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (10): : 2318 - 2328
  • [48] A Cost-Effective Reusable Tissue Mimicking Phantom for High Intensity Focused Ultrasonic Liver Surgery
    Guntur, Sitaramanjaneya Reddy
    Kim, Seong-Chan
    Choi, Min-Joo
    BIOENGINEERING-BASEL, 2022, 9 (12):
  • [49] PARAFFIN-GEL TISSUE-MIMICKING MATERIAL FOR ULTRASOUND-GUIDED NEEDLE BIOPSY PHANTOM
    Vieira, Silvio L.
    Pavan, Theo Z.
    Junior, Jorge E.
    Carneiro, Antonio A. O.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (12): : 2477 - 2484
  • [50] Tissue Mimicking Phantom for Visualization of Temperature Elevation Caused by Ultrasound
    Jung, Ji-hee
    Kim, Jung-soon
    Ha, Kang-lyeol
    Kim, Moo-joon
    Cao, Yonggang
    JOURNAL OF THE ACOUSTICAL SOCIETY OF KOREA, 2014, 33 (05): : 291 - 299