Pipe Efficiency Analysis at a Water Utility

被引:5
|
作者
Singh, Amarjit [1 ]
Adachi, Stacy [2 ]
机构
[1] Univ Hawaii Manoa, Dept Civil & Environm Engn, Honolulu, HI 96822 USA
[2] Univ Hawaii Manoa, Water Resources Res Ctr, Honolulu, HI 96822 USA
关键词
Availability; Reliability; Input and output measures; Efficiency; Linear programming; Costs per break per mile; Length in ground; MTBB; MTFF;
D O I
10.1061/(ASCE)PS.1949-1204.0000071
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A water utility company has many actions and decisions to take in order to run operations efficiently and effectively. One of them is to decide which types of pipe(s) to install as they do not all perform the same. Because these pipes may remain installed underground for more than 100 years, the decision to install is substantially binding. The pipe types considered here are ductile iron (DI), cast iron, PVC, and concrete cylinder (CC). The approach was to study cost and quality control measures and then apply data envelopment analysis in linear programming to determine the relative inefficiency of the specific pipe type in comparison to the rest of the pipe system. Data were taken from the main-break database and records and reports published by the Honolulu Board of Water Supply. Quality control measures evaluated included availability and reliability at the system and individual levels. It was determined that CC pipes were more inefficient than the others. Multiple scenarios of output measures were evaluated, such as combinations of system and individual levels, availability, and reliability. In all such evaluations, it was conclusively seen that CC pipes were relatively inefficient. Consequently, it is recommended the utility plan to replace CC pipes with corresponding DI and PVC piping.
引用
收藏
页码:23 / 34
页数:12
相关论文
共 50 条
  • [21] Analysis of Premature Failure of a PVC Water Pipe
    Edgar Espejo
    Journal of Failure Analysis and Prevention, 2023, 23 : 1491 - 1497
  • [22] Analysis of Premature Failure of a PVC Water Pipe
    Espejo, Edgar
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2023, 23 (04) : 1491 - 1497
  • [23] Failure analysis of a PVC potable water pipe
    EspejoMora, Edgar
    ENGINEERING FAILURE ANALYSIS, 2019, 98 : 189 - 189
  • [24] Analysis of water pipe breakage in Krosno, Poland
    Pietrucha-Urbanik, K.
    Studzinski, A.
    ENVIRONMENTAL ENGINEERING IV, 2013, : 59 - 62
  • [25] USING HOMOTHETIC COMPOSED ERROR FRONTIERS TO MEASURE WATER UTILITY EFFICIENCY
    FOX, WF
    HOFLER, RA
    SOUTHERN ECONOMIC JOURNAL, 1986, 53 (02) : 461 - 477
  • [26] Consistency in efficiency benchmarking: urban water utility regulation with performance improvement
    Gidion, Dickson K.
    Hong, Jin
    Hou, Bojun
    Shillamkwese, Samson S.
    Adams, Magdalene Z. A.
    Khoveyni, Mohammad
    WATER SUPPLY, 2019, 19 (07) : 1955 - 1964
  • [27] Cost efficiency of Tunisian water utility districts: Does heterogeneity matter?
    Ben Amor, Tawfik
    Mellah, Thuraya
    UTILITIES POLICY, 2023, 84
  • [28] Increasing Efficiency By Using Four-Pipe Water Source Heat Pumps
    Nassif, Nabil
    ASHRAE JOURNAL, 2021, 63 : 24 - 31
  • [29] Increasing efficiency by using four-pipe water source heat pumps
    Nassif, Nabil
    ASHRAE Journal, 2021, 63 (04) : 24 - 31
  • [30] Finite element analysis of utility pipe tunnel affected by adjacent deep excavation
    College of Civil Engineering and Architecture, China Three Gorges University, Yichang 443000, Hubei, China
    不详
    不详
    Adv. Mater. Res., 1600, (1327-1331):