Biological fixation of comminuted subtrochanteric fractures with proximal femur locking compression plate

被引:37
|
作者
Saini, Pramod [1 ]
Kumar, Rakesh [1 ]
Shekhawat, Vishal [2 ]
Joshi, Narendra [2 ]
Bansal, Mahesh [2 ]
Kumar, Senthil [1 ]
机构
[1] All India Inst Med Sci, Dept Orthopaed, New Delhi 110029, India
[2] Sawai Man Singh Med Coll & Hosp, Dept Orthopaed, Jaipur 302004, Rajasthan, India
关键词
Proximal femur-locking compression plate; Subtrochanteric fractures; Biological fixation; ANGLED BLADE PLATE; DYNAMIC CONDYLAR SCREW; FEMORAL NAIL PFN; LONG-GAMMA-NAIL; INTRAMEDULLARY FIXATION; INDIRECT REDUCTION; INTERNAL-FIXATION; HIP SCREW; OSTEOSYNTHESIS; EXTRAMEDULLARY;
D O I
10.1016/j.injury.2012.10.037
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Subtrochanteric fractures are difficult fractures associated with high incidence of complications and various implants, both intramedullary and extramedullary, are available for their fixation. Traditional extramedullary implants are associated with higher rate of implant failure and varus collapse while the biomechanically better intramedullary nails are technically demanding and are associated with higher re-operation rates. This study was done to evaluate the outcome following biological (indirect) fixation of unstable comminuted subtrochanteric fractures with proximal femur-locking compression plate (PF-LCP). Methods: Thirty-five consecutive patients with comminuted subtrochanteric fractures were operated upon with PF-LCP by using an indirect reduction technique. Seinsheimer types 3-5 fractures were included in the study. Operating time, blood loss and any technical difficulty with the implant were recorded. Patients were followed clinically and radiologically for union at fracture site and implant-related complications. The Harris Hip Score was used to document hip function at final follow-up. Results: Thirty-two patients with average age of 44.7 years were available for final evaluation. The mean operating time was 79.5 min and total blood loss averaged 233.13 ml. Union was achieved in all cases with an average time of 15.62 weeks. Complications included two cases of delayed union and two cases of infection. Two cases had a shortening of 1 cm and one case had malunion with external rotation. No instances of implant failure or nonunion were recorded. Conclusion: Biological fixation of comminuted subtrochanteric fractures with PF-LCP provides stable fixation with high union rate and fewer complications. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:226 / 231
页数:6
相关论文
共 50 条
  • [41] Minimally invasive plate osteosynthesis of subtrochanteric femur fractures with a locking plate: a prospective series of 20 fractures
    Chang-Wug Oh
    Jung-Jae Kim
    Young-Soo Byun
    Jong-Keon Oh
    Joon-Woo Kim
    Shin-Yoon Kim
    Byung-Chul Park
    Hyun-Joo Lee
    Archives of Orthopaedic and Trauma Surgery, 2009, 129 : 1659 - 1665
  • [42] The locking attachment plate for proximal fixation of periprosthetic femur fractures—a biomechanical comparison of two techniques
    Mark Lenz
    Markus Windolf
    Thomas Mückley
    Gunther O. Hofmann
    Michael Wagner
    Robert G. Richards
    Karsten Schwieger
    Boyko Gueorguiev
    International Orthopaedics, 2012, 36 : 1915 - 1921
  • [43] Clinical outcome of conventional versus biological fixation of subtrochanteric fractures by proximal femoral locked plate
    El-Desouky, Ihab I.
    Mohamed, Molham M.
    Kandil, Ahmed E.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (06): : 1309 - 1317
  • [44] Proximal femoral locking compression plate for proximal femoral fractures
    Lee, Wei Ting
    Murphy, Diarmuid
    Kagda, Fareed H. Y.
    Thambiah, Joseph
    JOURNAL OF ORTHOPAEDIC SURGERY, 2014, 22 (03) : 287 - 293
  • [45] Proximal femoral locking compression plate for proximal femoral fractures
    Pandey, Krishna Kumar
    Maravi, Lakhan Singh
    Turkar, Rajesh
    JOURNAL OF ORTHOPAEDIC SURGERY, 2015, 23 (01) : 133 - 134
  • [46] Principles of Locking Plate Fixation of Proximal Humerus Fractures
    Omid, Reza
    Trasolini, Nicholas A.
    Stone, Michael A.
    Namdari, Surena
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2021, 29 (11) : E523 - E535
  • [47] COMPRESSION FIXATION OF SUBTROCHANTERIC FRACTURES
    ASHER, MA
    TIPPETT, JW
    ROCKWOOD, CA
    ZILBER, S
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1976, (117) : 202 - 208
  • [48] Biomechanical Comparison of Proximal Locking Plates and Blade Plates for the Treatment of Comminuted Subtrochanteric Femoral Fractures
    Floyd, John C. P.
    O'Toole, Robert V.
    Stall, Alec
    Forward, Daren P.
    Nabili, Marjan
    Shillingburg, Daniel
    Hsieh, Adam
    Nascone, Jason W.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (09) : 628 - 633
  • [49] Fixation of Subtrochanteric Fractures in Two Patients with Osteopetrosis Using a Distal Femoral Locking Compression Plate of the Contralateral Side
    Srivastav Amit
    Agarwal Shehkar
    Mittal Vivek
    Srivastav Shekhar
    Nadkarni Biren
    European Journal of Trauma and Emergency Surgery, 2010, 36 : 263 - 269
  • [50] Fixation of Subtrochanteric Fractures in Two Patients with Osteopetrosis Using a Distal Femoral Locking Compression Plate of the Contralateral Side
    Amit, Srivastav
    Shehkar, Agarwal
    Vivek, Mittal
    Shekhar, Srivastav
    Biren, Nadkarni
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2010, 36 (03) : 263 - 269