Comparison of the effects of endovenous laser ablation at 1470 nm versus 1940 nm and different energy densities

被引:16
|
作者
Boim de Araujo, Walter Junior [1 ]
Ribas Timi, Jorge Rufino [1 ]
Kotze, Luiz Roberto [2 ]
Vieira da Costa, Cleber Rafael [3 ]
机构
[1] Univ Fed Parana UFPR, Dept Surg, Curitiba, PR, Brazil
[2] Lab Biopsia, Curitiba, PR, Brazil
[3] UFPR, Polytech Ctr, Dept Cell Biol, Curitiba, PR, Brazil
关键词
Varicose veins; endovenous thermal ablation; GREATER SAPHENOUS-VEIN; DIODE-LASERS; MODEL;
D O I
10.1177/0268355518778488
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives To evaluate histological and immunohistochemical changes in the great saphenous vein after endovenous laser ablation at two different wavelengths (1470 vs. 1940 nm) and linear endovenous energy density values (50 vs. 100 J/cm). Method Segments were obtained from the conventional eversion removal of great saphenous vein and divided into a control group and four groups for ex vivo irradiation (control group; A: 1470 nm, 50 J/cm; B: 1470 nm, 100 J/cm; C: 1940 nm, 50 J/cm; D: 1940 nm, 100 J/cm). Fifty venous segments (n = 10/group) were analyzed. Changes were classified into low-temperature changes, moderate-temperature changes, high-temperature changes, and very high-temperature changes. Results In the intima, low-temperature changes + moderate-temperature changes were significantly more prevalent in group A (65.4%) than in D (p = 0.001). In the media, low-temperature changes + moderate-temperature changes were achieved mostly in groups A and C (77.4% and 75.0%, respectively). In adventitia fragments, 100% of changes in group A were low-temperature changes + moderate-temperature changes. Conclusions The 1940-nm laser wavelength with linear endovenous energy density of 100 J/cm was excessively destructive to the intima and media causing a high rate of high-grade thermal damage. These findings corroborate the possibility of using lower linear endovenous energy densities with 1940-nm devices to achieve effective occlusion with less high grade thermal damage to the intima and media, as well as to prevent damages to the adventitia and perivenous tissues, including venous perforation and its attendant clinical consequences.
引用
收藏
页码:162 / 170
页数:9
相关论文
共 50 条
  • [41] Lower energy endovenous laser ablation of the great saphenous vein with 980 nm diode laser in continuous mode
    Kim, HS
    Nwankwo, IJ
    Hong, K
    McElgunn, PSJ
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 29 (01) : 64 - 69
  • [42] Does laser wavelength have a clinical effect during endovenous laser treatment for superfical venous insufficiency? A prospective observational study comparing the 810 nm and 1470 nm endovenous laser wavelength
    El-Sheikha, J.
    Nandhra, S.
    Wallace, T.
    Nehemiah, S.
    Carradice, D.
    Chetter, I.
    BRITISH JOURNAL OF SURGERY, 2014, 101 : 50 - 51
  • [43] Comparison of 1470nm laser and 1470nm laser heat head for ex vivo kidney tissue cutting: a preliminary study
    Zhou Zhentian
    Zhang Lupeng
    Liu Jiafeng
    Shun Zhi
    Li Wenzhi
    Liu Zhuwen
    Liang Zhiyuan
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS VI, 2014, 9268
  • [44] Endovenous Laser Ablation with 980-nm Diode Laser: Early and Midterm Results
    Ergenoglu, Mehmet Umit
    Sayin, Mehmet Murat
    Kucukaksu, Deniz Suha
    PHOTOMEDICINE AND LASER SURGERY, 2011, 29 (10) : 691 - 697
  • [45] Favorable long-term results of endovenous laser ablation of great and small saphenous vein incompetence with a 1470-nm laser and radial fiber
    Pavei, Patrizia
    Spreafico, Giorgio
    Bernardi, Enrico
    Giraldi, Enzo
    Ferrini, Maurizio
    JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2021, 9 (02) : 352 - 360
  • [46] Effect of Compression Stockings after Endovenous Laser Ablation of the Great Saphenous Vein with a 1470 nm Diode Laser Device and a 2ring Fiber
    Fischer, Laura
    Maurins, Uldis
    Rabe, Eberhard
    Rits, Juris
    Kadiss, Arnolds
    Prave, Sandra
    Vigants, Rets
    Pannier, Felizitas
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (17)
  • [47] Endovenous laser ablation of great saphenous veins using a 1470 nm diode laser and the radial fibre - follow-up after six months
    Pannier, F.
    Rabe, E.
    Rits, J.
    Kadiss, A.
    Maurins, U.
    PHLEBOLOGY, 2011, 26 (01) : 35 - 39
  • [48] Mid-term and Long-term Outcomes of Endovenous Laser Ablation Utilizing a 1470 nm Laser a Systematic Review and Meta-Analysis
    Bontinis, Vangelis
    Bontinis, Alkis
    Giannopoulos, Argirios
    Manaki, Vasiliki
    Kontes, Ioannis
    Pitoulias, Apostolos G.
    Chorti, Angeliki
    Ktenidis, Kiriakos
    JOURNAL OF ENDOVASCULAR THERAPY, 2024,
  • [49] Endovenous laser therapy for occlusion of incompetent saphenous veins using 1940nm
    Sroka, Ronald
    Pongratz, Thomas
    Esipova, Anna
    Dikic, Slobodan
    Demhasaj, Sahit
    Comsa, Florin
    Schmedt, Claus-Georg
    MEDICAL LASER APPLICATIONS AND LASER-TISSUE INTERACTIONS VII, 2015, 9542
  • [50] Comparison between contact diode laser with 980 nm and 1470 nm wavelengths for posterior laryngofissure in pigs
    Rodrigues, Isaac de Faria Soares
    Guerreiro Cardoso, Paulo Francisco
    Nepomuceno da Silva, Natalia Aparecida
    Correia, Aristides Tadeu
    Minamoto, Helio
    Bibas, Benoit Jacques
    Xavier Costa, Natalia de Souza
    Mancini, Marilia Wellichan
    Dolhnikoff, Marisa
    Pego-Fernandes, Paulo Manuel
    SCIENTIFIC REPORTS, 2024, 14 (01):