Portable Handheld Slit-Lamp Based on a Smartphone Camera for Cataract Screening

被引:18
|
作者
Hu, Shenming [1 ,2 ,3 ]
Wu, Hong [4 ]
Luan, Xinze [3 ]
Wang, Zhuoshi [2 ]
Adu, Mary [3 ]
Wang, Xiaoting [3 ]
Yan, Chunhong [2 ]
Li, Bo [4 ]
Li, Kewang [4 ]
Zou, Ying [4 ]
Yu, Xiaoya [4 ]
He, Xiangdong [5 ]
He, Wei [1 ]
机构
[1] Northeastern Univ, Coll Med & Biol Informat Engn, Shenyang 110016, Peoples R China
[2] He Eye Specislists Hosp, Shenyang 110000, Peoples R China
[3] He Univ, Shenyang 110000, Peoples R China
[4] Shenyang Eyerobo Co Ltd, Shenyang 110000, Peoples R China
[5] Shenyang Eye Ind Technol Res Inst, Shenyang 110000, Peoples R China
关键词
CLASSIFICATION-SYSTEM; NUCLEAR CATARACT;
D O I
10.1155/2020/1037689
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. As part of plans to provide help to people in remote and poor areas who have no medical resources, a portable slit-lamp based on a smartphone was proposed. This would help in early screening of cataract diseases.Methods. This means a microlens is designed that would work with a phone's camera. The phone's photo taking function is used in capturing the image of the eyes lens to replace the observation system of the desktop slit-lamp. A simplified slit light band was designed. In order for the light source part to meet the portable requirements of the slit-lamp, the adjustable and diffused light functions of the ligaments were removed in this design. Furthermore, the images collected by the smartphone are uploaded to the deep learning cataract screening system, which can achieve real-time and effective screening of cataract.Results. Unlike the desktop slit-lamp, which needs skilled personnel to operate, this device can be easily operated by less-skilled or inexperienced doctors. This eliminates the concerns of inaccurate diagnosis based on the use of unskilled professionals. Due to the portability, ease of use, and simplicity in obtaining crystal images of this device, it serves as a promising platform for nonhospital screening and telemedicine.Conclusions. In this paper, we invented a small portable device for screening cataract. This device is to make screening and diagnosis of cataract in remote areas very fast and effective. It will also solve the problem of inadequate specialized doctors and equipment in those areas as well.Translational Relevance.Smartphones can be used with portable slit-lamps to capture the images of the lens.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] An Automatic Diagnosis System of Nuclear Cataract Using Slit-lamp Images
    Li, Huiqi
    Lim, Joo Hwee
    Liu, Jiang
    Wong, Damon Wing Kee
    Tan, Ngan Meng
    Lu, Shijian
    Zhang, Zhuo
    Wong, Tien Yin
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 3693 - +
  • [22] Slit-lamp Based Ocular Fluorometry Scanning
    Domingues, J. P.
    Alberto, M.
    Correia, C.
    Cunha-Vaz, J.
    14TH NORDIC-BALTIC CONFERENCE ON BIOMEDICAL ENGINEERING AND MEDICAL PHYSICS, 2008, 20 : 217 - +
  • [23] AGING STUDIES ON NORMAL LENS USING THE SCHEIMPFLUG SLIT-LAMP CAMERA
    KASHIMA, K
    TRUS, BL
    UNSER, M
    EDWARDS, PA
    DATILES, MB
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (01) : 263 - 269
  • [24] SOME IMPROVEMENTS ON THE NIKON HIGH MAGNIFICATION PHOTO SLIT-LAMP CAMERA
    DEKERK, AA
    TREFFERS, WF
    INTERNATIONAL OPHTHALMOLOGY, 1981, 3 (02) : 117 - 119
  • [25] Clinical Observation of Allergic Conjunctival Diseases with Portable and Recordable Slit-Lamp Device
    Yazu, Hiroyuki
    Shimizu, Eisuke
    Sato, Shinri
    Aketa, Naohiko
    Katayama, Taiichiro
    Yokoiwa, Ryota
    Sato, Yasunori
    Fukagawa, Kazumi
    Ogawa, Yoko
    Tsubota, Kazuo
    Fujishima, Hiroshi
    DIAGNOSTICS, 2021, 11 (03)
  • [26] QUANTIFICATION OF SENILE CATARACT IN THE SLIT-LAMP IMAGE OF THE ZEISS SLC MEASURING SYSTEM
    NIESEL, P
    MULLER, D
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1988, 192 (02) : 173 - 175
  • [27] Slit-lamp based laser Doppler measuring system
    Fedosov, IV
    SARTOV FALL MEETING '99: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE, 2000, 4001 : 174 - 177
  • [28] Commentary: Smartphone-based, wireless, slit-lamp imaging with small footprint - making photodocumentation easy
    Akkara, John Davis
    Kuriakose, Anju
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (05) : 1262 - 1263
  • [29] Clinical evaluation of corneal ulcer with a portable and smartphone-attachable slit lamp device: Smart Eye Camera
    Ghafarian, Sadegh
    Masoumi, Ahmad
    Tabatabaei, Seyed Ali
    Yaseri, Mehdi
    Shimizu, Eisuke
    Nakayama, Shintaro
    Khemlani, Rohan Jeetendra
    Nishimura, Hiroki
    Asadigandomani, Hassan
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [30] Effectiveness of optometrist screening for diabetic retinopathy using slit-lamp biomicroscopy
    Prasad, S
    Kamath, GG
    Jones, K
    Clearkin, LG
    Phillips, RP
    EYE, 2001, 15 (5) : 595 - 601