Femoral Head Size and Wear of Highly Cross-linked Polyethylene at 5 to 8 Years

被引:116
|
作者
Lachiewicz, Paul F. [1 ]
Heckman, Daniel S. [2 ]
Soileau, Elizabeth S. [1 ]
Mangla, Jimmi [3 ]
Martell, John M. [3 ]
机构
[1] Chapel Hill Orthoped Surg & Sports Med, Chapel Hill, NC 27514 USA
[2] Univ N Carolina, Dept Orthopaed, Chapel Hill, NC 27514 USA
[3] Univ Chicago, Med Ctr, Sect Orthopaed Surg & Rehabil Med, Chicago, IL 60637 USA
关键词
TOTAL HIP-ARTHROPLASTY; MOLECULAR-WEIGHT POLYETHYLENE; RADIOSTEREOMETRIC ANALYSIS; CLINICAL-PERFORMANCE; ACETABULAR COMPONENT; UNCEMENTED SOCKETS; PENETRATION RATE; 3RD-BODY WEAR; DISLOCATION; REPLACEMENT;
D O I
10.1007/s11999-009-1038-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Wear of highly cross-linked polyethylene is reportedly independent of head size. To confirm that observation we asked in our population whether head size related to wear with one type of electron beam highly cross-linked polyethylene. Of 146 hips implanted, we evaluated complete clinical and radiographic data for 90 patients (102 hips or 70%). The minimum followup was 5 years (mean, 5.7 years; range, 5-8 years). The head size was selected intraoperatively based on the size of the acetabular component and presumed risk of dislocation. Polyethylene wear measurements were performed in one experienced laboratory using the method of Martell et al. There was no hip with pelvic or femoral osteolysis. The median linear wear rate was 0.028 mm/year (mean, 0.04 mm/year), and the median volumetric wear rate was 25.6 mm(3)/year (mean, 80.5 mm(3)/year). Median total volumetric wear was 41.0 mm(3) (mean, 98.5 mm(3)). We found no association between femoral head size and the linear wear rate, but observed an association between larger (36- and 40-mm) head size and volumetric wear rate and total volumetric wear. Although the linear wear rate of polyethylene was not related to femoral head diameter, there was greater volumetric wear (156.6 mm(3)/year) with the 36- and 40-mm heads. Pending long-term studies of large head sizes, we advise caution in using larger femoral heads in young or active patients and in those with a low risk of dislocation. Level of Evidence: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
引用
收藏
页码:3290 / 3296
页数:7
相关论文
共 50 条
  • [31] Different wear in two highly cross-linked polyethylene liners in THA: wear analysis with EBRA
    Dammerer, D.
    Keiler, A.
    Putzer, D.
    Lenze, F.
    Liebensteiner, M.
    Thaler, M.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (09) : 1591 - 1599
  • [32] Minimum 5-Year Wear Analysis of First-Generation Highly Cross-Linked Polyethylene in Patients 65 Years and Younger
    Ranawat, Amar S.
    Tsailis, Panagiotis
    Meftah, Morteza
    Koob, Trevor W.
    Rodriguez, Jose A.
    Ranawat, Chitranjan S.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (03): : 354 - 357
  • [33] Does increased diameter of metal femoral head associated with highly cross-linked polyethylene augment stress on the femoral stem and cortical hypertrophy?
    Seiya Ishii
    Yasuhiro Homma
    Tomonori Baba
    Yuichi Shirogane
    Kazuo Kaneko
    Muneaki Ishijima
    International Orthopaedics, 2021, 45 : 1169 - 1177
  • [34] Does increased diameter of metal femoral head associated with highly cross-linked polyethylene augment stress on the femoral stem and cortical hypertrophy?
    Ishii, Seiya
    Homma, Yasuhiro
    Baba, Tomonori
    Shirogane, Yuichi
    Kaneko, Kazuo
    Ishijima, Muneaki
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (05) : 1169 - 1177
  • [35] Early femoral head penetration of a highly cross-linked polyethylene liner vs a conventional polyethylene liner - A case-controlled study
    Krushell, RJ
    Fingeroth, RJ
    Cushing, MC
    JOURNAL OF ARTHROPLASTY, 2005, 20 (07): : 73 - 76
  • [36] Highly Cross-Linked Polyethylene in Total Hip Arthroplasty for Osteonecrosis of the Femoral Head: A Minimum 5-Year Follow-Up Study
    Min, Byung-Woo
    Lee, Kyung-Jae
    Song, Kwang-Soon
    Bae, Ki-Cheor
    Cho, Chul-Hyun
    JOURNAL OF ARTHROPLASTY, 2013, 28 (03): : 526 - 530
  • [37] Highly Cross-Linked Polyethylene in Total Hip Arthroplasty in Patients Younger Than 50 Years With Osteonecrosis of the Femoral Head: A Minimum of 10 Years of Follow-Up
    Min, Byung-Woo
    Cho, Chul-Hyun
    Son, Eun-Suck
    Lee, Kyung-Jae
    Lee, Si-Wook
    Song, Kwang-Soon
    JOURNAL OF ARTHROPLASTY, 2020, 35 (03): : 805 - 810
  • [38] Improvements of wear resistance of bearing with phospholipid polymer-grafted cross-linked polyethylene acetabular liner and ceramic femoral head
    Kyomoto, Masayuki
    Transactions of Japanese Society for Medical and Biological Engineering, 2014, 52
  • [39] Does highly cross-linked polyethylene wear less than conventional polyethylene in total hip arthroplasty?
    Glyn-Jones, Sion
    Saac, Sherif
    Hauptfleisch, Jennifer
    McLardy-Smith, Peter
    Murray, David W.
    Singh, Harinderjit
    JOURNAL OF ARTHROPLASTY, 2008, 23 (03): : 337 - 343
  • [40] Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners
    Bradford, L
    Baker, DA
    Graham, J
    Chawan, A
    Ries, MD
    Pruitt, LA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (06): : 1271 - 1282